Download Print this page
Toshiba RAS-B10UFV Installation Manual

Toshiba RAS-B10UFV Installation Manual

Split type
Hide thumbs Also See for RAS-B10UFV:

Advertisement

INSTALLATION MANUAL

AIR CONDITIONER (SPLIT TYPE)
Indoor unit
RAS-(B) 10, 13, 18UFV Series
Outdoor unit
RAS-10, 13, 18SAV Series
RAS-M14GAV-E
RAS-M18GAV-E
RAS-3M18SAV-E
RAS-3M26GAV-E1
RAS-4M23SAV-E
RAS-4M27GAV-E1
RAS-5M34UAV-E
ENGLISH
ESPAÑOL
FRANÇAIS
ITALIANO
DEUTSCH
PORTUGUÊS
POLSKI
ČESKY
PУCСКИЙ
HRVATSKI
MAGYAR
TÜRKÇE
NEDERLANDS
ΕΛΛΗΝΙΚΑ
SVENSKA
SUOMI
NORSK
DANSK
ROMÂNĂ
БЪЛГАРСКИ
EESTI
LATVISKI
SLOVENČINA
SLOVENŠČINA
Toshiba 1112150201 (CVF)

Advertisement

loading
Need help?

Need help?

Do you have a question about the RAS-B10UFV and is the answer not in the manual?

Questions and answers

Summarization of Contents

Installation Diagram of Indoor and Outdoor Units
Optional Installation Parts
Lists and describes optional parts required for installation.
Outdoor Unit Fixing Bolt Arrangement
Details on securing the outdoor unit with bolts and nuts.
Indoor Unit Installation
Indoor Unit Installation Place
Guidelines for selecting an appropriate location for the indoor unit.
Mounting the Installation Plate
Steps for securing the mounting plate and positioning screws.
Cutting Hole and Mounting Plate
Instructions for preparing the wall opening and mounting the plate.
Outdoor Unit Installation
Outdoor Unit Installation Place
Guidelines for selecting an appropriate location for the outdoor unit.
Precautions for Cold Regions Installation
Specific measures for installing in areas with snow and low temperatures.
Draining Water from Outdoor Unit
Instructions for draining water from the outdoor unit.
Refrigerant Piping Connection
Steps for connecting refrigerant pipes, including flaring.
Outdoor Unit Piping and Electrical Work
Flare Pipe Tightening Torque
Specifies torque values for connecting flare pipes with R410A refrigerant.
Evacuating the Refrigerant System
Procedures for removing air and moisture from the system.
Wiring Connection
Instructions for connecting the indoor and outdoor unit wiring.
Electrical Work
Details on power supply, wiring, and circuit requirements.
Indoor Unit Mounting and Concealed Installation
Mounting Directly on the Floor
Instructions for fixing the indoor unit directly onto the floor.
Wall Installation of Indoor Unit
Procedure for installing the indoor unit directly onto a wall.
Concealed Indoor Unit Installation
Method for installing the indoor unit recessed within the wall.
Outdoor Unit Installation Requirements
Outdoor Unit Installation Place
Guidelines for selecting an appropriate location for the outdoor unit.
Precautions for Cold Regions Installation
Specific measures for installing in areas with snow and low temperatures.
Draining Water from Outdoor Unit
Instructions for draining water from the outdoor unit.
Refrigerant Piping Connection
Steps for connecting refrigerant pipes, including flaring.
Outdoor Unit Piping and Electrical Work
Flare Pipe Tightening Torque
Specifies torque values for connecting flare pipes with R410A refrigerant.
Evacuating the Refrigerant System
Procedures for removing air and moisture from the system.
Wiring Connection
Instructions for connecting the indoor and outdoor unit wiring.
Electrical Work
Details on power supply, wiring, and circuit requirements.
Other Installation Procedures
Gas Leak Test
Procedure to check for refrigerant gas leaks after installation.
Setting of Remote Control Selector Switch
Instructions for setting remote control switches for multiple units.
Test Operation
How to perform a test run of the air conditioner.
Auto Restart Setting
Instructions on how to enable or disable the auto restart function.
Remote Control A-B Selection