Leda 340 Installation And Owner's Manual
Leda 340 Installation And Owner's Manual

Leda 340 Installation And Owner's Manual

Solar hot water heater

Advertisement

Solar Hot Water
Installation and Owner Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 340 and is the answer not in the manual?

Questions and answers

Summary of Contents for Leda 340

  • Page 1 Solar Hot Water Installation and Owner Manual...
  • Page 2 This   m anual   p rovides   i nformation   r elating   t o   t he   f ollowing   p roducts:   LEDA   s olar   h ot   w ater   h eater,   s plit   s ystem   w ith   e lectric   b ooster,  ...
  • Page 3   Index   Section   1   –   I nstallation   i nstructions   Pre-­‐installation   c hecklist   Installing   t he   h ot   w ater   s torage   t ank   Installing   t he   p ump   a nd   s olar   c ontroller   Installing  ...
  • Page 4   water,   may   have   high   mineral   content   which   can   cause   clogging   of   pipes   and   fittings.     LEDA   solar   water   heaters   are   of   an   “open   loop”   design   meaning   that   potable  ...
  • Page 5 -­‐ the   d istance   b etween   t he   t ank   a nd   s olar   c ollector   p anels   s hould   b e   n o   m ore   t han   15  ...
  • Page 6 7. Determine   i f   t he   l ocation   i s   i n   a   f rost   p rone   a rea.   If   t he   l ocation   e xperiences   f rost,   e ven   o n   r are   o ccasions,   t he   a ppliance   w ill   r equire   f rost   protection  ...
  • Page 7       Assemble  the  plumbing  fittings  (see  the  Tank  Parts  Kit  components  on  the  following  pages)   in   a ccordance   w ith   t he   f ollowing   i llustration:           7  ...
  • Page 8       Note:       If   t he   w ater   h eater   i s   a n   e lectric   b oosted   s olar   s ystem,   t he   h ot   w ater   s upply   feeds  directly  to  the  tempering  valve  as  there  is  no  gas  booster.    Also  note  ...
  • Page 9 HWP049   15mm   F I   F lexible   1   Item   1 1.   T o   c onnect   p ump   a ssembly   Connector   1 75mm   to   5 -­‐way   t ee   a t   t he   b ase   o f   t he   t ank   Long  ...
  • Page 10 The   pump   and   controller   assembly   includes   a   Flow   Meter   which   should   be   checked   and   adjusted,   i f   n ecessary,   d uring   i nstallation   t o   a   f low   r ate   o f   o ne   l itre   p er   m inute.    ...
  • Page 11 Installing   t he   f low   a nd   r eturn   l ines       SAFETY   W ARNING!     Do   n ot   u se   p lastic   p ipe   f or   t he   f low   a nd   r eturn   l ines   c onnecting   t he    ...
  • Page 12       WARNING!     Do   n ot   s witch   o n   t he   e lectric   e lement   u ntil   t he   s torage   t ank   i s   f ull    ...
  • Page 13 On   a   tile   roof   ensure   there   is   sufficient   roof   space   to   allow   the   removal   of   tiles   to   fix   the   mounting  rails  and  stainless  steel  mounting  straps  to  the  underlying  roof  rafters  at  the  top   and  ...
  • Page 14     Tighten   all   fittings   but   do   not   over-­‐tighten.     USE   TWO   SPANNERS   for   each   fitting;   one   for   the  fitting  itself  and  one  for  the  panel  header  nut  which  will  ensure  no  damage  is  done  to   the  ...
  • Page 15 LEDA   s olar   h ot   w ater   s ystems   d esigned   f or   g as   b oosting   u tilise   a   h ot   w ater   s torage  ...
  • Page 16 4. Turn   o ff   t he   i nternal   t ap   a nd   a llow   t he   s ystem   t o   p ressurise;     5. Turn   o n   t he   e lectricity   s upply   t o   t he   s olar   c ontroller   a nd   c irculating   p ump;    ...
  • Page 17       Frost   P rotection     Kit   M odel   N o.   HWK091               Product   C ode   Description   Qty.       HWP440   Solar   F rost   V alve   1  ...
  • Page 18 If   your   model   is   electrically   boosted,   the   tank   is   fitted   with   a   standard   3.6   kWh   Kawai   or   Backer   element.     Other   sized   elements   are   available.     Please   contact   your   LEDA  ...
  • Page 19   The   LEDA   6   Star   rated   continuous   flow   gas   boosters   come   in   two   sizes,   i.e.   20   litres   per   minute   a nd   2 6   l itres   p er   m inute,   a nd   a lso   i n   t wo   m odels,   i .e.   N atural   G as   a nd   L P   G as.     P lease  ...
  • Page 20     LEDA   s olar   c ollector   p anels   a re   2 .45   m   i n   a rea   w ith   t he   f ollowing   s pecifications:    ...
  • Page 21 Also  note  that  the  pump  will  turn  off  for  5  minutes  after  two  hours  of  operation  and  then   turn   o n   a gain   a utomatically   t o   p revent   p ossible   c avitation.     T he   p ump   u ses   a   v ery   l ow   2 0-­‐30   watts  ...
  • Page 22 HOT   WATER   VALVE   AND   EXTREME   CARE   IS   NEEDED   TO   PREVENT   SCALDING   OR   INJURY.     The  PTR  valve  should  not  normally  leak  water  and  if  this  occurs,  please  contact  your  LEDA  ...
  • Page 23   Maintenance     Proper   maintenance   of   your   solar   hot   water   system   will   ensure   its   correct   operation   and   performance   a s   w ell   a s   e xtend   i ts   l ife.    ...
  • Page 24 Certifications   a nd   l icenses                       Section   3   –   O wner   o perating   i nstructions        ...
  • Page 25 The  greater  the  number  of  STCs  awarded,  the  higher  the  solar  performance.    Please   take   care   of   your   LEDA   solar   hot   water   system   by   maintaining   and   operating   it   in  ...
  • Page 26 If   a   product   fails   to   conform   to   this   warranty   during   the   applicable   warranty   period,   LEDA   will   either   replace   any   failed   component   of   the   product   or   replace   the   product   free   of  ...
  • Page 27  either  directly  or  indirectly  due  to  defects  of  any  kind  in  a  product  will  only  be  met  by   LEDA   w here   t he   d amage   o r   l oss   w as   r easonably   f oreseeable   b y   L EDA.  ...
  • Page 28             LEDA’s   c ontact   d etails   a re   a s   f ollows:   Leda       Ph:   1 800   6 97   6 52   E:  ...

Table of Contents