Overview
This document describes the specification of the PZEM-013/015 DC multifunction battery tester, this meter is mainly used to test
all kinds of battery's voltage, discharge current, discharge power, discharge impedance, internal resistance, capacity, dump energy,
energy consumption and running time, and display the measurement data through LCD screen.
PZEM-013: Measuring Range 10A (Built-in Shunt)
PZEM-015: Measuring Range 300A (use external shunt, can matched with 50A, 100A, 200A, 300A four kinds of shunt).
1. Function description
1.1 Voltage
1.1.1 Measuring range: 0-200V. (when the test voltage is <8V, please use the independent power supply mode)
1.1.2 Display format: <10V display as: 9.99V
<100V display as: 99.9V
≥100V display as: 199V
1.1.3 Minimum resolution:0.01V
1.1.4 The starting test voltage: 0.05V
1.1.5 Measurement accuracy:1%
1.2 Current
1.2.1 Measuring range: 0-10A. (Type: PZEM-013)
0-300A(Type: PZEM-015) can set 50A, 100A, 200A,300A four range depend on the external shunt, the factory
default is 100A.
1.2.2 Display format: <1A display as: 999mA
<10A display as: 9.99A
<100A display as: 99.9A
≥100A display as: 199A
1.2.3 Minimum resolution: 1mA
1.2.4 The starting test current: 10mA(Type: PZEM-013)
1.2.5 Measurement accuracy:1%
Multifunction Battery Tester
20mA(Type: PZEM-015)

Advertisement

loading
Need help?

Need help?

Do you have a question about the PZEM-013 and is the answer not in the manual?

Questions and answers

Summary of Contents for Morning PZEM-013

  • Page 1 Multifunction Battery Tester Overview This document describes the specification of the PZEM-013/015 DC multifunction battery tester, this meter is mainly used to test all kinds of battery’s voltage, discharge current, discharge power, discharge impedance, internal resistance, capacity, dump energy, energy consumption and running time, and display the measurement data through LCD screen.
  • Page 2 <100W display as: 99.9W <1000W display as: 999W <10000W display as: 9.99kW ≥10000W display as: 19.9kw 1.3.3 Minimum resolution: 0.01W 1.3.4 The starting test power: 0.1W (Type: PZEM-013) 0.2W (Type: PZEM-015) 1.3.5 Measurement accuracy:1% 1.4 Impedance Impedance=Voltage/ Current 1.4.1 Measuring range: 0-1000Ω...
  • Page 3 Note: Before you test the internal resistance, you should preset the full voltage depend on the battery type, after it is fully charged you can use it to test; if you do not fully charge it, you can set the battery without load voltage is the full voltage, then test; the internal resistance is not a fixed value, the more the battery discharged, the bigger the resistance.
  • Page 4 1.9 Running time 1.9.1 Measuring range: 0 ~ 999 hour (without load the time will not accumulate) 1.9.2 Display format: 0:00:00 ~ 999:59:59 Over the test range will become zero. 2. Operating Instructions 2.1 Setting the full and cur-off voltage Figure 1: the normal display interface Figure 2: the voltage setting interface 2.1.1 Set the full voltage:...
  • Page 5 Figure 5: cut-off voltage setting interface Figure 6: cut-off voltage setting interface (low bit) (high bit) 2.1.2 Set the Cut-off voltage: Step 1: After you set the full voltage, loner press the button until LCD shows the interface of Fig. 5, then release the button; Step 2: At this time, the battery symbol shows the zero-grid to indicate the cut-off voltage setting state, the default cut-off voltage is 016.0V, the setting method is the same as above;...
  • Page 6 Figure 9 clear the energy interface Step 1: In the normal display interface, long press the button until the LCD shows the interface of Figure 2, then release the button, short press the button again switch to the interface to Figure 9, it indicates that this state is the clearing energy setting state. Step 2: Longer press the button until the data has been cleared and exit the setting status, restore the normal display interface.
  • Page 7 In dormant mode, short press the button will switch to the normal display mode. Note: The meter will stop all measurement functions in dormant mode, so please do not switch to dormant mode if normal measurement is performed. 3. Wiring Diagram Figure 12 PZEM-013 Wiring Diagram Figure 13 PZEM-015 Wiring Diagram 4.Dimension Figure(mm)...
  • Page 8 Figure 14 LCD Screen size Figure 15 Out frame size Figure 16 Hole size Figure 17 Height size 5. Matters needing attention 5.1 This module is suitable for indoor, please do not use outdoor. 5.2 Applied load should not exceed the rated voltage, current. 5.3 Wiring order can’t be wrong.
  • Page 9 -20’C ~ +60’C.