MODEL
AU-A1ZB120
VOLTAGE (V)
220-240
LED DRIVER MAX LOAD
120W PF ≥ 0.9
RESISTIVE MAX LOAD
250W
INPUT CURRENT
1.05A
OUTPUT VOLTAGE
210V DC
AMBIENT TEMPERATURE LIMITS
MAX 50°C
IP RATING
IP20
NUMBER OF OPERATING CYCLES
1E4
CIRCUIT DISCONNECTION
Electronic Disconnection
PROTOCOL
Zigbee HA1.2
CONDUCTOR TYPE & SIZE
Twin and Earth 0.75~1.5 mm
Flat x2C+E 0.75~2.5 mm
FREQUENCY BAND
2400MHz - 2483.5MHz
MAX OUTPUT RF POWER
10dBm/mW
INSULATING MATERIALS
PTI 175
GLOW-WIRE TEMPERATURE
650°C
PROTECTIVE DEVICE
3.15A non-replaceable built-in fuse
RATED IMPULSE WITHSTAND VOLTAGE 2500V
USING THE APP TO CONNECT THE MODULE TO THE HUB
1. Follow instructions on the App to pair the Hub with the AONE
2. Put the module into pairing mode by:
a) Pressing the button for 3 seconds, or,
b) Powering the module off for 5 seconds and back on again 3 times
The module will flash twice to indicate it has entered pairing mode.
The module will flash a third time to indicate that it has successfully paired with
the HUB.
The module can then be controlled using the app.
• There are no restrictions of use.
• Installation must be carried out in accordance with the latest edition of the
Wiring Rules by a qualified electrician.
• Earth terminal is for Termination only.
• Hereby, Aurora Limited declares that the radio equipment type
AU-A1ZB120 is in compliance with Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the following internet address:
www.auroralighting.com/ProductDetail/AU-A1ZB120
1
Turn off the power
Note: Ensure the light
fittings being installed
are dimmable
4
2
(UK)
2
(Australia)
7mm
CONDUCTOR TYPE
TWIN AND EARTH 0.75~1.5 MM
& SIZE
FLAT X2C+E 0.75~2.5 MM
6
8
Turn on the power
www.auroralighting.com
2
3
2
(UK)
2
(AUSTRALIA)
7
CEILING VOID REQUIREMENTS
Insert driver into the ceiling void and lay flat on the surface
9
Note 1: For setup of the inline dimmer remember that
light switch must be turned on.
Note 2: When installed successfully and turned on,
the light switch will flash twice until you are
paired and should remain turned on for control
through the App and remote.
5
Standard
wiring
L
N
N1
L1
EARTH
220-240V
Loop in
The product is Class II. However,
loop out
it is provided with a terminal
wiring
for earth continuity in case of
systems with earth conductor.
Cut-out diameter
55mm
65mm
Ceiling Void Depth
47mm
X
X
53mm
X
X
60mm
X
X
67mm
X
X
75mm
X
X
80mm
X
115mm
Document Version: AU-A1ZB120_V1_18
Insert
68mm
72mm
X
X
X
X
X
X
Need help?
Do you have a question about the AU-A1ZB120 and is the answer not in the manual?
Questions and answers