Page 3
Children may not play with the appliance. If you need a new power cable, always order the replacement from Brink Climate Systems B.V. To prevent dangerous situations, a damaged mains connection must...
Electric connections..............................5.4.1 Connection of the power plug ............................ 5.4.2 “Brink Air control” connection............................. Display ..........................................................General explanation “Brink Air control”........................View on Display ................................. Main menu ................................. 6.4.1 Device information menu ............................6.4.2 Basic settings menu ..............................
Scope of delivery Before starting installation of the heat recovery unit, check that it has been supplied complete and undamaged. The scope of delivery of the heat recovery unit Renovent Sky P200 includes the following components: 1: Heat recovery appliance 2: Wall mounting bracket kit;...
Page 7
423010 200 mm 200 mm 660 mm 660 mm 482 mm 482 mm Silencer- / air distribution box Ø75 mm (20x) 423011 200 mm 200 mm 660 mm 660 mm 482 mm 482 mm Servicetool 531961 Renovent Sky P200 618097-A...
When ordering an appliance always state the correct type; highly labour- intensive. The Renovent Sky P200 comes ready to plug in with a 230 V mains plug. The appliance comes not standard with a “Brink Air control”, connection of a simple 4-way switch is possible as well.
Chapter 3 Version 3.1 Technical information Renovent Sky P200 Supply voltage [V/Hz] 230/50 Protection degree IP20 Dimensions (w x d x h) [mm] 1000 x 660 x 198 Duct diameter [mm] Ø160 External diameter condensate discharge [“] Weight [kg] 23,5...
1 Supply air 2 Exhaust air 3 Extract air 4 Outdoor air 5 Electric connections 6 Connection condensate discharge Fan graph Note: The value stated in the circle is the capacity per fan (in Watt) = [W] Renovent Sky P200 618097-A...
- the temperature from the dwelling is lower than the temperature set at step no. 5 in the settings menu minus the set temperature by the hysteresis (step no. 6), this temperature is factory 22 °C (24,0 °C minus 2,0 °C). Renovent Sky P200 618097-A...
• The safety regulations for low-voltage installations. regulations must be complied with. Placing the appliance The Renovent Sky P200 can directly be mounted to the wall or ceiling using the mounting brackets supplied for that purpose. possible to replace them in due course.
Page 14
Make sure that the screws used to mount the ap- pliance to the wall or ceiling are capable of bear- ing the weight of the Renovent Sky P200. Connecting the mounting brackets to the appliance: The mounting brackets can be attached to the appliance using the four pre-drilled holes on the housing of the appliance.
Before connecting the condensate discharge to the appliance, cannot be removed from the appliance for service pour water into the U-trap to create an air trap. 3/4” Detachable coupler Detachable coupler Renovent Sky P200 618097-A...
5.4.2 “Brink Air control” connection The “Brink Air control” (option) must be connected to the eBus connector. This (detachable) 2-pole eBus connector is mounted on the outside of the appliance (see also §10.1).
Settings in the “Brink Air control” software is set for the English language. In the setting menu “Brink Air of the Renovent Sky P200 can be called up and changed with Control”, §6.4.2, you can choose a language.
Chapter 6 Display View on Display When the Renovent Sky is in operating mode, the “Brink Flow rate indicator eBus connection indicator 10.54 01.03.16 Fan indicator HRU-Ventilation 0 8 :0 0 17:0 0 Fault symbol Filter message Current time block...
Chapter 6 Display Main menu Pressing the right-hand setting knob on the “Brink Air control” takes you to the 10.54 23/11/15 In this main menu you can use the right-hand setting knob to HRU-Ventilation 0 8 :0 0 17:0 0 select one of the 3 available manuals (rotate to select and press - Device information §6.4.1...
Airflow extract 0 m³/h Airflow extract 0 m³/h T dwelling 20.0 °C T dwelling 20.0 °C T atmosphere 15.3 °C T atmosphere 15.3 °C 0.0 % 0.0 % CO2-Sensor 1 CO2-Sensor 2 CO2-Sensor 3 CO2-Sensor 4 Renovent Sky P200 618097-A...
- Language Installer - Clock - Date - Backlight - Key lock Language In this menu you can choose a language; ex factory the “Brink Air Control” is set for the English language. 10.56 01.03.16 10.58 01.03.16 Basic settings Language Language...
Chapter 7 Fault Trouble shooting When the appliance control system detects a fault, it is indi- cated on the display of the “Brink Air control” with a spanner symbol, possibly together with a fault code. 10.59 01.03.16 Messages HRU-appliance History of errors 10.54...
(see § 9). either. If mode 2 of a multiple switch does not work, the modular connector of the multiple switch has been connected the wrong way round. Renovent Sky P200 618097-A...
Maintenance installer Installer maintenance includes cleaning the heat exchanger and fans. Dependent on the conditions, this must done about once every three years. Swing open the front panel (can also be taken from the hinges, if required). Renovent Sky P200 618097-A...
Page 30
Chapter 8 Maintenance For ceiling mounting, carefully remove the condensate bin; there may still be some condensate left in the condensate Rinse the exchanger with hot water and a regular detergent. max. 45 ºC Renovent Sky P200 618097-A...
Page 32
> ± 25 sec 10.54 23/11/15 HRU-Ventilation 08:00 17:00 Clic k! Filter reset; see §8.1 point 6 Press the Return key ( ) to leave any selected menu and the appliance will return to operating mode. Renovent Sky P200 618097-A...
P200 P200 green/ brown blue white nr.1 nr.2 green yellow yellow outdoor Indoor multiple control supply service Motor bypass temperature extract fan temperature switch board connector valve sensor sensor “Brink Air RH-sensor control” (optional) applicable (optional) Renovent Sky P200 618097-A...
1 or 2. The boost mode can be reset by putting the switch to setting 3 for longer than 2 seconds or by switching it to absence mode ( Renovent Sky P200 618097-A...
Important: Because of polarity sensitivity, always connect contacts X1-1 to X1-1 and contacts X1-2 to X1-2. Never connect X1-1 and X1-2. A maximum of 10 appliances (1 Master + 9 Slave max.) 10.4 Connection RH (humidity)-sensor Cable sleeve Setting parameter 28 & 29 (§12) Renovent Sky P200 618097-A...
Chapter 10 Electric connections accessories 30°C 25°C Minimum temperature Maximum temperature Supply air Exhaust air Extract air 15°C Outdoor air 10°C 3°C 0°C Setting parameter 25, 26 & 27 (§12) Renovent Sky P200 618097-A...
When ordering parts, in addition to the article code number (see exploded view), please state the type of the heat recovery appliance, the serial number, the year of production and the Appliance type : Renovent Sky P200 name of the part: Serial number : 424015234501...
Page 38
Control board (Plus version) When replacing, note the correct dip switch settings 531780 Cable with power plug 230 volt * 531782 The mains cable has a print connector. When replacing it, always order a replacement mains cable Brink without prior notice. Renovent Sky P200 618097-A...
7 (= No input fan activation) 2 (= Flow rate mode 1) Extract fan mode 3 (= Flow rate mode 2) 4 (= Flow rate mode 3) switching input 1 5 (= Multiple switch) 7 (= No extract fan activation) Renovent Sky P200 618097-A...
Page 40
15,0 °C - 40,0 °C 0,5 °C (Above this temperature the valve opens.) STEP OFF (= RH-sensor not active) RH-sensor ON (= RH-sensor active) +2 most sensitive Sensitivity 0 default setting RH-sensor RH-sensor -2 least sensitive Renovent Sky P200 618097-A...
Chapter 13 Declaration of conformity DECLARATION OF CONFORMITY This declaration of conformity is issued under the sole responsibility of the manufacturer. Manufacturers: Brink Climate Systems B.V. Address: Product Renovent Sky P200 The product described above complies with following directives: A2:2019 + A14:2019 + A15:2021 Staphorst, 11-10-2023 A.
Chapter 13 ErP-value Supplier: Brink Climate Systems B.V. Model: Renovent Sky P200 The annual electricity The annual heating saved SEC-Value Energyclass Climate zone Type of control consumption (AHS) in kWh/m²/a (SEC) (AEC) in kWh in kWh Manual -35,45 4359 “Brink Air control”...
Chapter 13 Recycling Recycling Sustainable materials are used in the manufacture of this appliance. The packaging should be disposed of in a responsible manner and inaccordance with governmental regulations. Renovent Sky P200 618097-A...