――― Preface ――― Thank you for purchasing “LP5394 Low Noise DC Power Supply”. Please read "Safety Precautions" first to ensure the product is used in a correct and safe manner. ● Alert Symbols in this Manual This manual uses the following alert symbols. The instructions by these alert symbols shall be carefully obeyed to ensure equipment operator’s safety, and prevent damage to equipment.
Should you encounter any anomaly like above, immediately contact us or our agent. Never use it until the repair is completed. ● Do not use in a gaseous atmosphere. This may pose a risk of explosion or other. LP5394...
Page 7
Indicates the ON position of the power switch. Indicates the OFF position of the power switch. Indicates that the external conductor of the connector is connected to the case. Indicates that the external conductor of the connector is connected to the output GND. LP5394...
Page 8
Safety Precautions ● Request about disposal This product does not include batteries and is designed in accordance with the RoHS Directive (EU). Dispose of the product in accordance with the laws and regulations of the area where you use it. LP5394...
" is a low noise DC power supply that achieved an output noise of 10 Vrms or lowers LP5394 (typical) (10 Hz to 20 MHz bandwidth) and output voltage stability of ±10 ppm/C (typical). The output voltage can be adjusted in the range of 0 to ±3 V, 0 to ±5 V, 0 to ±10 V, or 0 to ±15 V using the VOLTAGE RANGE switch and adjuster on the front panel.
Preparation Before Use Checking Before Use ......... 2-1 Installation ............2-3 Grounding and Power Connections ....2-7 Simplified Operation Check ......2-9 Inspection ............2-9...
The following shows the product configuration. Check that the quantities are correct and there is no scratch. Table 2-1 Configuration List ● LP5394 Main unit ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 1 ● Accessories Instruction manual ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 1 Power cord set (3 pole, 2 m) ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 1 Fuse (100 V/120 V: 0.315 A or 220 V/240 V: 0.125 A) (Time-Lag, 5.2×20 mm) ꞏꞏ...
Page 19
PA-001-2373: Output Cable B (for SA-200 and SA-400 Series except for SA-230F5, 2 m) PA-001-2374: Output Cable C (for SA-230F5, 2 m) PA-001-2590: BNC Adapter PA-001-2591: Binding Post Adapter PA-001-2642: Rack Mount Kit (EIA, for 4 units) PA-001-2643: Rack Mount Kit (JIS, for 4 units) LP5394...
Provide ventilation holes in the rack, or use a fan to forcibly cool the inside of the rack. ● Avoid dusty and humid locations. The insulation resistance may decrease and the leakage current will increase causing deterioration of performance. LP5394...
2.2 Installation Figure 2-2 Rack Mount Kit (JIS, for 4 Units) External View LP5394...
Page 23
This product may become corroded, or a malfunction may result. ・Near an electromagnetic field source, high-voltage device, or power line Noise may increase. ・Location where there is a lot of vibration Noise may increase or a malfunction may result. LP5394...
2) Turn off the power switch of this product. 3) Insert the power cord into the inlet on the rear panel of this product. 4) Insert the plug of the power cord into the outlet with a protective ground contact. LP5394...
WARNING To ensure that the power cord can be disconnected from the inlet on LP5394, allow sufficient space around the inlet, or to ensure that the power plug can be disconnected from the outlet, use an outlet in an easily accessible location and allow sufficient space around the outlet.
The periodic inspection interval varies depending on the operating environment and operating frequency, but it is recommended to perform periodic inspection for this product at least once every year. If inspection is required, contact us or our agent. Charges apply for inspection, calibration, and adjustment services. LP5394...
3.1 Panel Component Names and Functions Panel Component Names and Functions 3.1.1 LP5394 Panel Component Names and Functions See Figure 3-1 LP5394 Front and Rear Panel Views ■ Front Panel ① Voltage Meter This is a 15 V full-scale output voltage meter.
Page 29
3.1 LP5394 Panel Component Names and Functions ⑧ MONITOR terminals These are output voltage monitor terminals (mating pin diameter 2 mm). The output resistance of the monitor terminals is approximately 1 k. Therefore, it is recommended to monitor the output voltage with, for example, a multimeter with an input resistance of 1 M...
3.1 LP5394 Panel Component Names and Functions 3.1.2 BNC Adapter Panel Component Names and Functions Optional BNC adapter (PA-001-2590) for converting LOW NOISE DC POWER SUPPLY LP series output to BNC connector output is available. See Figure 3-2 BNC Adapter Front and Rear Panel Views ■...
(M3) (the length of the screws should be 5 mm or lower). Note that if the bottom plate is removed, LP5394 and the mounted adapter are electrically connected. The bottom plate is mounted to LP5394 using 8 mm plastic screws (M3).
If the voltage exceeds this value, the internal voltage limiting element works to suppress the voltage, but if the applied voltage (energy) is large, the voltage limiting element of this product may be damaged by heat. CAUTION Do not apply voltage between output terminals from outside. This product may be damaged. LP5394...
HR10-7P-4S (73) is used as the connector for output cable A (for SA-600 series) to be connected to the preamplifier. The outer body of the connector is connected to the chassis of the preamplifier. Output GND and the preamplifier chassis have the same electric potential. LP5394...
Page 35
If the voltage exceeds this value, the internal voltage limiting element of this product works to suppress the voltage, but if the applied voltage (energy) is large, the voltage limiting element of this product may be damaged by heat. LP5394...
If there is a device including any transformer such as a DC power supply nearby, install this product as far as possible from it. Install the product in a location where there is as little vibration as possible. Place and use the product in a stable location. LP5394...
(energy) is large, the voltage limiting element of this product may be damaged by heat. CAUTION Do not disconnect and connect the output cable A when this product output is on. SA-600 series may be damaged. LP5394 3-10...
Do not disconnect and connect the output cable B when this product output is on. SA-200 and SA-400 series may be damaged. If the power supply for SA-200 and SA-400 series is connected in reverse, SA-200 and SA-400 series may be damaged. Before connection, check the power polarity again. LP5394 3-11...
(energy) is large, the voltage limiting element of this product may be damaged by heat. CAUTION Do not disconnect and connect the output cable C when this product output is on. SA-230F5 may be damaged. LP5394 3-12...
(energy) is large, the voltage limiting element of this product may be damaged by heat. CAUTION Do not disconnect and connect the output cable A when this product output is on. The module connected to the valuation kit may be damaged. LP5394 3-13...
The chassis of the BNC adapter and output GND have the same electric potential. When the BNC adapter is used by applying voltage to the output GND, do not connect the BNC adapter with the chassis GND of this product. LP5394 3-14...
The chassis of the binding post adapter and output GND have the same electric potential. When the binding post adapter is used by applying voltage to the output GND, do not connect the binding post adapter with the chassis GND of this product. LP5394 3-15...
If this product is used under environmental conditions that over the specifications (0 to +50 C [day's average temperature 40 C or lower], 25 to 80 %RH [absolute humidity 1 to 25 g/m lower]), this product may malfunction. LP5394 3-16...
・Precautions and storage method when the product is not used for a long period of time. ・Precautions for repacking and transportation. For the simplified operation check, refer to 2.4. If the specifications fail to be met in the operation check or performance test, contact NF Corporation for calibration or repair. Daily Maintenance ●...
If necessary, select the correct voltage with a Coin-driver. WARNING This product has high-voltage portions inside. Never remove the cover. When inspection into the inside of the product is needed, never allow anybody to touch the innards except our certified service engineers. LP5394...
5.1 LP5394 Specifications LP5394 Specifications Output current: ±0.1 A, unless otherwise noted, 5.1.1 Type Series regulator 5.1.2 Output 5.1.2.1 Voltage/Current Voltage 0 to ±15 V Voltage setting range Set with the VOLTAGE RANGE switch on the front panel. Setting range 3 0 to ±3 V...
5.1 LP5394 Specifications 5.1.3 Input 5.1.3.1 Power Input Input voltage AC 100, 120, 220 and 240 V (select switch) ±10 % However, AC 250 V or lower Frequency 50/60 ±2 Hz Power consumption 25 VA or lower Overvoltage category 5.1.3.2 Fuse...
5.1 LP5394 Specifications 5.1.4.4 Environmental Conditions Altitude 2000 m or lower 0 to +50 C, day's average temperature 40 C or lower Operating temperature range Operating humidity range 25 to 80 %RH, absolute humidity 1 to 25 g/m non-condensation 10 to +50 C, day's average temperature 40 C or lower...
Standard Data Standard Data ........... 6-1 Output Noise Voltage Waveforms ..... 6-1 Output Noise Voltage Density Frequency Characteristic ............ 6-2 Long Time Drift Characteristic ......6-2 Temperature Drift ..........6-3...
Figure 6-3 Output Noise Voltage Density Frequency Characteristic (+15 V Output, Rated Voltage) Long Time Drift Characteristic +40 ppm +15 V -0.2 -0.4 -0.6 40 ppm -0.8 -1.0 時間[hour] Time [hour] Figure 6-4 Long Time Drift Characteristic (Rated Load, Output Voltage Reference at Time of Start) LP5394...
6.5 Temperature Drift Temperature Drift 10 ppm +15 V -15 V +10 ppm 温度 [ ℃ ] C Temperature [ Figure 6-5 Temperature Drift (Rated Load, 23 C reference) LP5394...
Page 63
All NF products are warranted against defects in materials and workmanship for a period of one year from the date of shipment. During the warranty period, NF will repair the defective product without any charge for the parts and labor. For repair service under warranty, the product must be returned to either NF or an agent designated by NF.
Page 64
We assume no responsibility for influences resulting from the operations in this manual. Copyright 2015-2022, NF Corporation LP5394 INSTRUCTION MANUAL NF Corporation 6-3-20, Tsunashima Higashi, Kohoku-ku, Yokohama...