  • Page 2: Revision History

    Updated max supply voltage to 3.6V 3 May 2022 Dave Drogowski Erik Lins Updated Laird default appEUI 13 Mar 2023 Robert Gosewehr Senthooran Ragavan 2 May 2025 Updated to Ezurio format Dave Drogowski Olivia Chang https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 3: Table Of Contents

    915-928 MHz AS ......................................... 14 7.3.4 915-928 MHz AU ......................................... 14 7.3.5 Data rate control ........................................15 Device Operation ............................................15 Care and Maintenance ........................................15 Positioning of the Sensor ........................................ 15 https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 4 10.10 Alerts and Backlogs ......................................... 28 10.11 Battery Life Calculator ........................................28 Integrating Sentrius™ Sensor into a Third-Party Application ..........................28 Bluetooth SIG ............................................... 29 Regulatory ..............................................29 Ordering Information ..........................................30 https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 5 Hong Kong (HK – 923 MHz) ..................................... 35 1.2.1 Australia (AU – 915 MHz or 923 MHz) ..................................35 Additional information ..........................................36 Appendix A - Cayenne packet format ...................................... 36 Additional Information ..........................................38 https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 6: About This Guide

    In order to comply with the LoRaWAN spec, Ezurio offers several different versions of the Sentrius Sensor. Regions covered include Europe (EU), North America (US) and Australia (AU915) and a growing number of countries in the Asia (AS) region.
  • Page 7: Architecture Overview

    28 hours, or (25 mA x 28 hours) 700 mA/hours. The rated capacity is 2500 mA/hours, so it lasted only 28% of its rated value. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 8: Changing Battery Type

    0 through 100%, as shown in Table 1 - Battery percentage values Value Percentage Range < 5 5 – 20 21 - 40 41 - 60 61 - 80 81- 100 https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 9: Alkaline Battery Level Measurement

    Table 5 - Alkaline battery levels at 20° C Level Remaining Voltage (V) >2.78 >2.68 >2.55 >2.48 >2.3 Table 6 – Alkaline battery levels at 40° C Level Remaining Voltage (V) >2.85 >2.75 >2.65 >2.5 >2.3 https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 10: Lithium Battery Level Measurement

    Sentrius™ 4.1.1 Default AppEUI The default AppEUI is 0xec,0xc0,0x7a,0x00,0x00,0x00,0x00,0x06, and it is set in the device by Ezurio at the time of manufacturing. Note: Previous Ezurio default appEUI: F9C60ECEA3ADC6BD. Any sensor/sensor kit assembled after date code: 0223451 will contain the new appEUI.
  • Page 11: Deveui

    RS1xx User Guide 4.2 DevEUI The DevEUI is an 8-byte ID used to uniquely identify your device. It is assigned and set in the device by Ezurio at the time of manufacturing. 4.2.1 Reading the DevEUI Back Label The DevEUI is printed on the back label of the sensor as...
  • Page 12: Configuring The Packet Format

    LoRa Radio Settings and Info The packet format can be configured on the Mobile App through the option. Figure 7: Packet format menu A brief summary of the different formats is shown in Table 9 https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 13: Configuring The Packet Type

    RS1xx for transmission at a later time. With confirmed packets, if three successive uplinks are not acknowledged, the sensor tries to rejoin. Unconfirmed packets continue to be transmitted while the sensor is powered. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 14: Adaptive Data Rate (Adr)

    Sensor starts transmitting Join requests alternately on a random 125-kHz channel at data rate 2 in the selected sub- Sentrius™ band and then a random 500-kHz channel at data rate 6. It continues this sequence until the sensor joins the network. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 15: Data Rate Control

    Most importantly, keep the sensor away from warm/humid environments after removing from the chiller/freezer • 8.4 LoRa Messages Note: The LoRa API is available in the ‘RS1xx LoRa Protocol Guide’ which is available from the RS1xx product page. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 16: Join Sequence

    Every two unsuccessful attempts at a data rate causes the sensor to lower its data rate by one. Refer to the following tables for how many attempts are made at each data rate. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 17: Disconnect

    This is required for the sensor to store data in the internal log flash. The sensor transmits data without the network time being available, but it cannot commit this to flash storage. This does not apply when configured for the Cayenne packet format, due to the protocol not supporting a timestamp. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 18: Logging Feature

    While a unit is in the backoff state, it continues to read the sensor, but it stores its data to FLASH. The backoff period could be assigned to the sensor from which the backlog is extracted, other sensors in the network, or both, depending on the application. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 19: Operation At 902-928 Us With Dr0

    FLASH. A flag is set in the uplink message notifying the server of the configuration error. It is the responsibility of the server to update the sensor configuration to use an aggregate count of one if it is desired not to backlog data in this case. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 20: Alarm Levels

    The LoRa network server can request the sensor firmware version from the sensor. 8.14 Resetting the Sensor Reset the sensor by holding down the Bluetooth button for a minimum of five seconds. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 21: Configuration

    Set the min/max temperature values that will trigger an alarm condition Set Temp Humidity Sensor Read Set parameters related to reading the sensor and sending data Options over LoRa Set Friendly Name Set a user-friendly name on the device https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 22: Mobile Application

    Sensor App and install on device. Sentrius 10.3 Connect to Sentrius Sensor Figure 11 Press the Bluetooth button (see #2 on Figure 11: Top of the Sentrius Sensor begins advertising and become connectable. Sentrius https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 23: Select Device

    Figure 12: Select the applicable device 10.4 Main Screen Figure 13 is the main screen of the mobile application when an integrated temp/humidity Sentrius sensor is connected. Figure 13: Mobile application main https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 24: Sensor Configuration

    LED during LoRa transmit and the orange LED during LoRa receive. See the LED Behavior section of this guide for additional information. Note: The LED flash has an impact on battery life. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 25: View Sensor Data

    As there is no indication of time on the graph this can cause confusion. 10.6 LoRa Configuration Navigation Screen Comments Use to update LoRa Keys. Note: AppKey is write-only for security reasons. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 26: Lora Network

    Screen Comments Use the LoRa Info page to view data on the LoRa Network. 10.8 BLE Info Navigation Screen Comments Use the BLE Info page to view information on the BLE connection. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 27: Update Firmware

    Select the appropriate file to start the update process. The Test Versions and New Region button are for internal Ezurio use only. They are password protected so as to avoid incorrect use. Note: The sensor does not allow downgrading the firmware.
  • Page 28: Alerts And Backlogs

    Note: The mobile application is written in Xamarin (C#), a product by Microsoft designed for cross-platform (Android + iOS) development. The source code for the project is available from Ezurio as mentioned above. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 29: Bluetooth Sig

    3147A-RM191 Taiwan (NCC) Temp/Humidity External Temp Sensor: Temp/Humidity Ext. Port RTD Temp – RS191 only Sensor: Open/Closed Sensors: Sensor: CCAF20LP146AT2 CCAF20LP1460T0 CCAF20LP146BT4 CCAF20LP146CT6 – RS191 only Australia – RS191 only New Zealand https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 30: Ordering Information

    Sentrius RS1xx User Guide 13 Ordering Information See the Ezurio RS1xx product page for ordering information. 13.1 Evaluation Kit Details (applies to 455-0001, 455-0002, and other regional variants) https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 31: Other Variants

    Sensor is available with an external sensor port – RJ45 (Figure 15). It allows users to connect an external Open/Closed sensor to Sentrius™ perform remote contact state measurements. Figure 15: External Open/Closed Sensor port and cable assembly https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 32: External Rtd Sensor

    (blue housing) with an RJ45 port. Users must be sure to connect the appropriate sensor cable assembly with the intended enclosure. Please check the product description on the sensor label / part number on the packaging if in doubt. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 33 Sentrius RS191 Sensor, Temp & Humidity, AU, 915 MHz 455-00062 450-0182 Sentrius RS191 Sensor, Temp & Humidity, AU, 923 MHz 455-00063 455-00095 450-0182 Sentrius RS191 Sensor, Temp & Humidity, SG, 923 MHz https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 34: Label Info

    *Warning* The larger white space area is only available on older versions of the sensor which will have the label shown in the lower left below. The label layout generally may change at any time. Figure 18: Back label white space. https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 35: As923 Region Labels

    Hong Kong (HK – 923 MHz) Figure 22: Hong Kong AS923 Region Label 1.2.1 Australia (AU – 915 MHz or 923 MHz) Note: The different 480-part numbers. Figure 23: Australia AU915 Region Label https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 36: Additional Information

    Data Channel Header Temperature Data Header 0x67 Temperature Data MSB 0xXX Temperature Data LSB 0xXX Data Channel Header 0x02 0x02 Analog Input Header (remaining battery life) Battery Voltage MSB 0xXX 0xXX Battery Voltage LSB https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 37 Table 17 Table 17: Cayenne Open/Closed sensor packet format Index Value Description 0x04 Data Channel Header 0x66 Presence Data Header 0xXX Open/Closed sensor status, 0 = Closed, 1 = Open https://www.ezurio.com/ © Copyright 2025 Ezurio All Rights Reserved...
  • Page 38: Additional Information

    Ezurio materials or products for any specific or general uses. Ezurio or any of its affiliates or agents shall not be liable for incidental or consequential damages of any kind. All Ezurio products are sold pursuant...

This manual is also suitable for: