1. Specifications Wall mounted Type Inverter, Heat pump Model name ASUH09KTAS ASUH12KTAS ASUH15KTAS Power supply intake Outdoor unit Voltage 208/230 System power supply Frequency Available voltage range 187—253 Indoor unit power supply (from outdoor unit) 208/230 2.64 3.52 4.25 Rated Btu/h 9,000 12,000...
Page 7
Wall mounted Type Inverter, Heat pump Model name ASUH09KTAS ASUH12KTAS ASUH15KTAS 11-5/8 × 35-3/16 × 11 (295 × 894 × 280) Dimensions in (mm) (H × W × D) Gross 14-3/16 × 39 × 14-9/16 (360 × 990× 370) 31 (14) Weight lb (kg) Gross...
After installation of mobile app, user registration is required. For user registration and setup infor- mation, refer to Setting Manual attached with the product. For the latest version of the wireless LAN control manuals, refer to the following web site. https://www.fujitsu-general.com/global/support/ - 4 - 2-1. System requirement...
¢ Installation space requirement Provide sufficient installation space for product safety. Unit: in (mm) Outline of unit 3 (75) or more 3 (70) or more 5 (127) or more 6 (133) or more 60 (1,500) or more - 6 - 3-1.
3-2. Pipe exit length from the rear Design the system considering the length of the pipes or hose exiting from the rear of the indoor unit. NOTE: Detailed shapes of the indoor unit and the tip of each pipe or hose may vary depending on the model.
5. Capacity table Capacity tables show each of following values calculated based on the outdoor temperature and the indoor temperature, under given Airflow Rate (AFR): For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP) For heating capacity: Total Capacity (TC) and Input Power (IP) 5-1.
8. Safety devices Model Type of ASUH09KTAS Protection form protection ASUH12KTAS ASUH15KTAS Circuit Current fuse (PCB*) 250 V, 3.15 A protection 302 ±27°F (150 ±15°C) Activate Fan motor stop Fan motor Thermal protector protection program 248 ±27°F (120 ±15°C) Reset Fan motor restart *PCB: Printed Circuit Board - 23 -...
9-1. External input With using external input function, some functions on this product can be controlled from an external device. • “Operation/Stop” mode or "Forced stop" mode can be selected with function setting of indoor unit. • A twisted pair cable (22 AWG) should be used. Maximum length of cable is 492 ft (150 m). •...
¢ External Input and Output PCB The indoor unit Operation/Stop can be set by using the input connector on the PCB. • Input select Use either one of these types of connectors according to the application. (Both types of connec- tors cannot be used simultaneously.) –...
¢ Input signal type • Indoor unit Input signal type is only "Edge". Edge • External Input and Output PCB The input signal type can be selected. Signal type (edge or pulse) can be switched by the DIP switch 2 (SW302) on the External Input and Output PCB.
9-2. External output Use an external output cable with appropriate external dimension, depending on the number of ca- bles to be installed. ¢ Indoor unit • A twisted pair cable (22 AWG) should be used. Maximum length of cable is 82 ft (25 m). •...
Page 33
¢ External Input and Output PCB • A twisted pair cable (22 AWG) should be used. Maximum length of cable is 82 ft (25 m). • Output voltage: High DC 12 V ±2 V, Low 0 V. • Permissible current: 50 mA •...
9-3. Setting of external input and output • Indoor unit Input Connection point Function setting number 46 Function Operation/Stop mode 1 (R.C. enabled) (Setting prohibited) CN46 Forced stop mode Operation/Stop mode 2 (R.C. disabled) Output Connection point Function setting number 60 Function Operation/Stop 01 to 04...
Page 35
• External Input and Output PCB Switch setting Ex IN Ex OUT Rotary SW302 CN313 CN314 CN310 CN311 CN312 switch Edge Operation/Stop Not available Indoor unit fan Operation/Stop Error status operation Pulse Operation Stop status Indoor unit fan Forced External heater Not available Error status operation...
9-4. Details of control input function ¢ Operation/Stop mode 1 • In the case of "Edge" input External Input and Output PCB Function External input Input signal Command setting Rotary SW302 switch Off → On Operation — Input of indoor unit CN46 On →...
Page 37
¢ Forced stop • In the case of "Edge" input External Input and Output PCB Function External input Input signal Command setting Rotary SW302 switch Forced stop Off → On (R.C. disabled) — Input of indoor unit CN46 Normal On → Off (R.C.
¢ Operation/Stop mode 2 • In the case of “Edge” input External Input and Output PCB Function External input Input signal Command setting Rotary SW302 switch Operation Off → On (R.C. enabled) — Input of indoor unit CN46 Stop On → Off (R.C.
¢ Forced thermostat off External Input and Output External input Input signal Command Rotary switch Off → On Thermostat off External Input and 2, B, C, D CN313 Output PCB On → Off Normal operation Off → On Thermostat off External Input and 4, 7, 8, A CN313...
9-5. Details of control output function ¢ Operation status External Input and Function Output PCB External output Output signal Status setting Rotary switch Off → On Operation 60-00 1, 2, 8 Output of indoor unit CN47 60-06 On → Off Stop Off →...
¢ Indoor unit fan operation status External Input and Function Output PCB External output Output signal Status setting Rotary switch Off → On Fan run 60-10 Output of indoor unit CN47 On → Off Fan stop Off → On Fan run External Input and —...
¢ External heater output Function setting Indoor unit Control Primary heater Auxiliary heater Control switching external heaters No. 61 Auxiliary heater control 1 Heat pump External device* 61-00 Auxiliary heater control 2 Heat pump External device 61-01 Heat pump prohibition External device None 61-02...
Page 43
• Inappropriate designing and installation of external heater may cause a fire by emitted heat from the external heater. • Fujitsu General Ltd. is not responsible for inappropriate designing or installation of external heat- ing device. - 39 - 9-5.
Page 44
Auxiliary equipment control by room temperature Auxiliary equipment control is switchable by room temperature. Auxiliary equipment switching is per- formed for each room temperature divided to following 3 zones. Zone A Ts +0.9°F (0.5 °C) Ts: Setting temperature Ts -0.9°F (-0.5 °C) Tr: Room temperature Zone B Zone C...
Auxiliary heater control 1 Operation Condition Heater on Heater is on as shown in following diagram of heating temperature. • Heater is off as shown in following diagram of heating temperature. • Other than heating mode Heater off • Error occurred •...
Page 46
Heat pump prohibition control Perform heating by external heater only. Indoor unit is continuous thermostat off. Operation Condition Heater on Heater is on as shown in following diagram of heating temperature. • Heater is off as shown in following diagram of heating temperature. •...
Page 47
Auxiliary heater control by outdoor temperature 1 This control selects heat pump or external heater according to the outdoor temperature. When out- door temperature is high, the heating is performed by using heat pump only. Operation Condition Heater on Heater is on as shown in following diagram of heating temperature.
Page 48
• Operation status 46.4°F (8°C) 42.8°F (6°C) Outdoor temperature (Factory setting) -0.4°F (-18°C) -4°F (-20°C) Heat pump Heat pump Combination zone only zone prohibition zone Outdoor temperature zone * Comp. On/Off 12 V Heater * The outdoor temperature zone transition from one to another will stay in that zone for minimum of 30 min. NOTE: In following operations, compressor will be on in heat pump prohibition zone.
Page 49
Auxiliary heater control by outdoor temperature 2 This control selects heat pump or external heater according to the outdoor temperature. Even when outdoor temperature is high, the heating is performed by using both of heat pump and external heater. Operation Condition Heater on...
Page 50
• Operation status 46.4°F (8°C) 42.8°F (6°C) Outdoor temperature (Factory setting) -0.4°F (-18°C) -4°F (-20°C) Heat pump prohibition Combination zone zone Outdoor temperature zone * Comp. On/Off 12 V Heater * The outdoor temperature zone transition from one to another will stay in that zone for minimum of 30 min. NOTE: In following operations, compressor will be on in heat pump prohibition zone.
Page 51
Auxiliary heater control by outdoor temperature 3 This control selects heat pump or external heater according to the outdoor temperature. Even when outdoor temperature is high, the heating is performed by using both of heat pump and external heater. Operation Condition Heater on...
Page 52
NOTE: In following operations, compressor will be on in heat pump prohibition zone. • Other than heating • Test run - 48 - 9-5. Details of control output function 9. External input and output...
Page 53
Auxiliary heat pump control • External heater output Operation Condition Heater on Heater is on as shown in following diagram of heating temperature. • Heater is off as shown in following diagram of heating temperature. • Other than heating mode Heater off •...
Page 54
Auxiliary heat pump control by outdoor temperature 1 • External heater output Operation Condition Heater on Heater is on as shown in following diagram of heating temperature. • Heater is off as shown in following diagram of heating temperature. •...
Page 55
• Operation status 46.4°F (8°C) 42.8°F (6°C) Outdoor temperature (Factory setting) -0.4°F (-18°C) -4°F (-20°C) Heat pump prohibition Combination zone zone Outdoor temperature zone * Comp. On/Off 12 V Heater * The outdoor temperature zone transition from one to another will stay in that zone for minimum of 30 min. NOTE: In following operations, compressor will be on in heat pump prohibition zone.
Page 56
Auxiliary heat pump control by outdoor temperature 2 • External heater output Operation Condition Heater on Heater is on as shown in following diagram of heating temperature. • Heater is off as shown in following diagram of heating temperature. •...
Page 57
• Operation status Heat pump prohibition zone 46.4°F (8°C) 42.8°F (6°C) Outdoor temperature (Factory setting) -0.4°F (-18°C) -4°F (-20°C) Combination zone Outdoor temperature zone * Comp. On/Off 12 V Heater * The outdoor temperature zone transition from one to another will stay in that zone for minimum of 30 min. NOTE: In following operations, compressor will be on in heat pump prohibition zone.
Page 58
Auxiliary heat pump control by outdoor temperature 3 • External heater output Operation Condition Heater on Heater is on as shown in following diagram of heating temperature. • Heater is off as shown in following diagram of heating temperature. •...
Page 59
• Operation status Heat pump prohibition zone 46.4°F (8°C) 42.8°F (6°C) Outdoor temperature (Factory setting) -0.4°F (-18°C) -4°F (-20°C) Combination zone Outdoor temperature zone * Comp. On/Off 12 V Heater * The outdoor temperature zone transition from one to another will stay in that zone for minimum of 30 min. NOTE: In following operations, compressor will be on in heat pump prohibition zone.
¢ Heating thermostat on for humidifier Indoor unit Function External output setting Situation Mode Rotary SW Heating Indoor unit fan Heating thermostat on operation thermostat on no. 60 status 60-05 CN47 Example of 60-06 CN312 individual Not used 60-07 CN311 connection 60-08 CN310...
10. Group connection NOTE: Group control cannot be used together with WLAN Adapter. Installation procedure for group control system: A number of indoor units can be operated at the same time using a single remote controller. NOTE: When different type of indoor units (such as wall-mounted type and cassette type, cassette type and duct type, or other combinations) are connected using group control system, some functions may no longer be available.
11. Remote controller 11-1. Wireless remote controller ¢ Overview a MODE button b FAN SPEED button c POWERFUL button d SET button (Left/right airflow) e MIN. HEAT button f INDIVIDUAL AUTO button g OUTDOOR LOW NOISE button h ENERGY SAVING button i RESET button j TEST RUN button k WLAN button...
Page 63
¢ Specifications Controller Unit: in (mm) Top view 2-5/16 (58) 11/16 (17) Front view Side view Size (H × W × D) in (mm) 7-1/8 × 2-5/16 × 11/16 (181 × 58 × 17) Weight oz (g) 4 (116) (without batteries) ...
12. Function settings To adjust the functions of this product according to the installation environment, various types of function settings are available. NOTE: Incorrect settings can cause a product malfunction. 12-1. Function settings by using remote controller Some function settings can be changed on the remote controller. After confirming the setting proce- dure and the content of each function setting, select appropriate functions for your installation envi- ronment.
¢ Contents of function setting Each function setting listed in this section is adjustable in accordance with the installation environ- ment. NOTE: Setting will not be changed if invalid numbers or setting values are selected. Function setting list Function no. Functions Filter sign 30/31...
Page 66
2) Room temperature control for indoor unit sensor NOTE: Before performing this setting, refer to Function 95. Depending on the installed environment, correction of the room temperature sensor may be re- quired. Select the appropriate control setting according to the installed environment. The temperature of the room temperature sensor is corrected as follows: Corrected temp.
3) Room temperature control for wired remote controller sensor NOTE: Before performing this setting, refer to Function 95. Depending on the installed environment, correction of the wire remote temperature sensor may be required. Select the appropriate control setting according to the installed environment. To change this setting, set Function 42 to “Both”...
Page 68
6) Remote controller custom code (Only for wireless remote controller) The indoor unit custom code can be changed. Select the appropriate custom code. Function number Setting value Setting description Factory setting ♦ 7) External input control “Operation/Stop” mode or “Forced stop” mode can be selected. Function number Setting value Setting description...
Page 69
10) Switching functions for external output terminal Functions of the external output terminal can be switched. For details, refer to “External input and output”. Function number Setting value Setting description Factory setting Operation status ♦ 01—04 Cooling thermostat On Heating operation Operation/Stop 07—08 Cooling thermostat On...
Page 70
13) Outdoor temperature zone boundary temperature A Setting required if changing of the outdoor temperature setting for heat pump prohibition zone is re- quired when auxiliary heater control by outdoor temperature 1 and 2 are performed on the indoor unit. For details, refer to “External heater output”...
Page 71
16) Heat pump backup setting Enables or disables the heat pump backup operation. Function number Setting value Setting description Factory setting Disable ♦ Enable 17) Emergency heat for external output terminal Enables or disables emergency heat input. Function number Setting value Setting description Factory setting Disable...
12-2. Custom code setting for wireless remote controller To interconnect the air conditioner and the wireless remote controller, assignment of the custom code for the wireless remote controller is required. NOTE: Air conditioner cannot receive a signal if the air conditioner has not been set for the custom code.
14. Optional parts 14-1. Controllers Exterior Part name Model name Summary Remote controller that provides the functions you need in a sleek design that uniquely transforms itself to blend with any interior. Optional Communication Kit is necessary for installation. NOTE: When this remote controller is connected, wireless Wired Remote remote controller cannot be...
Page 75
NOTES: • Available functions may differ by the remote controller. For details, refer to the operation manu- • When using the group controlling system of the Wired Remote Controller, using WLAN Adapter is prohibited. - 71 - 14-1. Controllers 14. Optional parts...
For connection between indoor unit with Modbus UART interface and a Modbus open UTY-VMSX Converter network. Connecting point: CN65 on Main PCB This converter can control Fujitsu General products using a third-party thermostat controller. Optional Thermostat UTY-TTRXZ Communication Kit is necessary for Converter installation.
1. Specifications Type Inverter, Heat pump Model name AOUH09KTAP1 AOUH12KTAP1 AOUH15KTAP1 Power supply 208/230 V~ 60 Hz Power supply intake Outdoor unit Available voltage range 187—253 V Starting current Cooling 1,136 (1,930) 1,377 (2,340) 1,472 (2,500) Airflow rate CFM (m Heating 1,042 (1,770) 1,107 (1,880)
3. Installation space 3-1. Models: AOUH09KTAP1, AOUH12KTAP1, and AOUH15KTAP1 ¢ Space requirement Provide sufficient installation space for product safety. CAUTION Keep the space shown in the installation examples. If the installation is not performed accordingly, it could cause a short circuit and result in a lack of operating performance.
Multiple outdoor unit installation • Provide at least 10 in (250 mm) of space between the outdoor units if multiple units are in- stalled. • When routing the piping from the side of an outdoor unit, provide space for piping. •...
Outdoor units installation in multi-row Unit: in (mm) Single parallel unit arrangement Multiple parallel unit arrangement 4 (100) or more 8 (200) or more 40 (1,000) 80 (2,000) or more or more 8 (200) or more 16 (400) or more 20 (500) or more 40 (1,000) or more 8 (200) or more...
6. Capacity compensation rate for pipe length and height difference Height difference H Indoor unit is higher than outdoor unit Indoor unit is lower than outdoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Connection pipe Connection pipe 6-1. Models: AOUH09KTAP1, AOUH12KTAP1, and AOUH15KTAP1 NOTE: Values mentioned in the table are calculated based on the maximum capacity.
10. Electrical characteristics Model name AOUH09KTAP1 AOUH12KTAP1 AOUH15KTAP1 Voltage 208/230 Power supply Frequency 13.2 15.7 19.4 MCA* Starting current MAX. CKT. BKR* Power cable Wiring Size spec.* Connection Limited wiring cable* ft (m) 69 (21) length NOTES: • *1: Minimum Circuit Ampacity (Calculation based on UL60335-2-40) •...
11. Safety devices Model Type of Protection form protection AOUH09KTAP1 AOUH12KTAP1 AOUH15KTAP1 250 V, 25 A Current fuse (PCB*) Circuit 250 V, 5 A protection Current fuse (Base pan heater) 250 V, 3.15 A 257±18°F (125±10°C) Activate Fan motor Fan motor stop Thermal protection program protection 248±18°F (120±10°C)
12. Accessories 12-1. Models: AOUH09KTAP1, AOUH12KTAP1, and AOUH15KTAP1 Part name Exterior Part name Exterior Installation manual Protection label Cable tie - 90 - 12-1. Models: AOUH09KTAP1, AOUH12KTAP1, and AOUH15KTAP1 12. Accessories...