  • Page 1 KT-MOD-IO16 RS-485 Input/Output Module Installation Manual DN2238-1904...
  • Page 2: Table Of Contents

    What is in the box? Technical specifications Typical wiring diagram Vital LED indicator chart SPI modules Resetting the KT-MOD-IO16 Input and Output terminals Mounting the KT-MOD-IO16 Installing and wiring the KT-MOD-IO16 Compliance specifications © 2019 Tyco Security Products. All rights reserved.
  • Page 3: End User License Agreement

    For KANTECH software provided with or without products or components IMPORTANT - READ CAREFULLY KANTECH software purchased with or without products and components is copyrighted and is purchased under the following license terms: • This End-User License Agreement (“EULA”) is a legal agreement between You...
  • Page 4: Description Of Other Rights And Limitations

    You may not make any changes or modifications to the Software, without the written permission of an officer of KANTECH. You may not remove any proprietary notices, marks or labels from the Software Product. You shall institute reasonable measures to ensure compliance with the terms and conditions of this EULA.
  • Page 5: Export Restrictions

    SOFTWARE PRODUCT is an upgrade, any transfer must also include all prior versions of the SOFTWARE PRODUCT. f - Termination - Without prejudice to any other rights, KANTECH may terminate this EULA if You fail to comply with the terms and conditions of this EULA. In such event, You must destroy all copies of the SOFTWARE PRODUCT and all of its component parts.
  • Page 6 THAT OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE. b - CHANGES IN OPERATING ENVIRONMENT KANTECH shall not be responsible for problems caused by changes in the operating characteristics of the HARDWARE, or for problems in the interaction of the SOFTWARE PRODUCT with non-KANTECH SOFTWARE or HARDWARE PRODUCTS.
  • Page 7 PRODUCT is an upgrade, any transfer must also include all prior versions of the SOFTWARE PRODUCT j - Termination - Without prejudice to any other rights, KANTECH may terminate this EULA if You fail to comply with the terms and conditions of this EULA. In such event, You must destroy all copies of the SOFTWARE PRODUCT and all of its component parts.
  • Page 8: Copyright Information

    © 2019 Tyco International Ltd. and its Respective Companies. All rights reserved. All specifications were current as of publication date and are subject to change without prior notice. EntraPass, Kantech and the Kantech logo are trademarks of Tyco International Ltd. and its Respective Companies.
  • Page 9 KT-MOD-IO16 RS-485 ioModule Installation Manual Reducing the clearance between SELV (Safety Extra Low Voltage) circuits and NON-POWER Limited Circuits (Battery wires) Route the battery wires away from the rest of the SELV circuit 6. It is the end-user and/or installer's responsibility to ensure that the disposal of the used batteries is made according to the waste recovery and recycling regulations applicable to the intended market.
  • Page 10: Technical Support

    Technical support For technical assistance with this and other Kantech products, contact technical support, Monday to Friday. To contact technical support, email access-support@jci.com or follow this link: http://www.kantech.com/Support/Contact_Technical_Support_Advanced.aspx See Table 1 for the technical support phone numbers and opening hours in your region.
  • Page 11 KT-MOD-IO16 RS-485 ioModule Installation Manual Asia GMT + 08:00 09:00 to 17:00 Toll free +800 CALL TYCO +800 2255 8926 Direct +86 21 6023 0650 China Direct +400 671 1528 India Direct +1 800 1082 008 Australia Direct +02 9684 3980...
  • Page 12: What Is In The Box

    • One KT-MOD-IO16 RS-485 Input/Output module. • One installation manual. • One accessory kit containing 4 plastic standoffs and 32 5.6K EOL resistors. Technical specifications See Table 2 for the technical specifications of the KT-MOD-IO16. Table 2: Technical specifications Model KT-MOD-IO16 Input voltage 9.5 VDC to 15 VDC...
  • Page 13 KT-MOD-IO16. Input wiring Up to 2000 ft or 600 m Firmware Field upgradable via RS-485. To verify the firmware version of the KT-MOD-IO16, refer to the relevant software user manual. Certifications FCC, CE, RoHS, WEEE Flammability rating UL 94 V-2...
  • Page 14: Typical Wiring Diagram

    Typical wiring diagram See Figure 1 for the typical wiring configuration of the KT-MOD-IO16. Figure 1: Typical wiring diagram © 2019 Tyco Security Products. All rights reserved.
  • Page 15 KT-MOD-IO16 RS-485 ioModule Installation Manual See Table 3 for descriptions of the wiring, condition, and state of each input configuration. Table 3: Contact input configuration Input Contact Wiring Condition State configuration type Dry contact See Figure A short is detected.
  • Page 16 See Figures 2 - 6 for illustrations of the wiring for each contact input configuration. Figure 2 Figure 3 NC Dry contact NO Dry contact Figure 4 Figure 5 NC Dry contact with EOL resistor NO Dry contact with EOL resistor Figure 6 NC Dry contacts with double EOL resistors ©...
  • Page 17: Vital Led Indicator Chart

    KT-MOD-IO16 RS-485 ioModule Installation Manual Vital LED indicator chart See Table 4 for descriptions of the KT-MOD-IO16's LED sequences and the state of the device that each LED sequence indicates. Table 4: Vital LED indicator chart Device state LED sequence...
  • Page 18: Spi Modules

    SPI modules Figure 7: SPI modules wiring diagram © 2019 Tyco Security Products. All rights reserved.
  • Page 19 KT-MOD-IO16 RS-485 ioModule Installation Manual SPI information Each KT-MOD-IO16 can have up to 8 SPI relay modules, up to a total of 64 relays (SPI) for each module. These can be with or without elevator control. You can have a total of 32 SPI relay modules.
  • Page 20: Resetting The Kt-Mod-Io16

    Resetting the KT-MOD-IO16 You can execute a soft reset or a factory default reset on the KT-MOD-IO16 using the push button (SW1) on the board. Executing a soft reset To execute a normal soft reset, press the Push Button for more than 100 ms (debounce) but for less than 3 seconds.
  • Page 21: Mounting The Kt-Mod-Io16

    • BSI Standard BS7671, latest edition. This applies to installations in the United Kingdom. The KT-MOD-IO16 does not come with a cable. To wire an SPI module to the KT- MOD-IO16, use the KT-MOD-SPI-16 cable that comes with the SPI module. Cut this cable at the header end and strip the wires.
  • Page 22 22 AWG cable or bigger. The terminal blocks support 12-30 AWG wires. Note: The voltage drop between the power source and the KT-MOD-IO16 should not exceed 10% of the supplied voltage in the worst condition when all devices that are powered from the module are energized at the same time.
  • Page 23 KT-MOD-IO16 RS-485 ioModule Installation Manual Note: If you use an external power source, make sure that you wire the COM terminal to the negative side of the power source correctly because the return current comes from one of the COM terminals.
  • Page 24: Compliance Specifications

    Compliance specifications United States This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 25: Australia And New Zealand

    KT-MOD-IO16 RS-485 ioModule Installation Manual supplied as second-hand equipment, equipment for sale outside the European Economic Area, or as spare parts for either a single unit or system, it is not covered by the Directives. Australia and New Zealand RCM Mark, Australia/NZ Emissions Compliant...
  • Page 26 © 2019 Tyco Security Products. All rights reserved.