Arctica HEG788 Instruction Manual

Blast chiller freezer

Advertisement

Quick Links

Thank you for purchasing your Arctica blast chiller/freezer.
To make full use of the product, please read this manual carefully before using and keep it
INSTRUCTION MANUAL
HEG788 Blast Chiller Freezer
25kg Chill / 15kg Freeze
HEG789 Blast Chiller Freezer
50kg Chill / 30kg Freeze
safe for future reference.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HEG788 and is the answer not in the manual?

Questions and answers

Summary of Contents for Arctica HEG788

  • Page 1 25kg Chill / 15kg Freeze HEG789 Blast Chiller Freezer 50kg Chill / 30kg Freeze Thank you for purchasing your Arctica blast chiller/freezer. To make full use of the product, please read this manual carefully before using and keep it safe for future reference.
  • Page 2: Table Of Contents

    Contents TECHNICAL PARAMETERS ............................ 3 1. INTRODUCTION..............................4 2. THE MANUFACTURER CANNOT BE HELD LIABLE IN THE FOLLOWING CASES: ........... 5 3. TRANSPORTATION AND STORAGE ........................5 4. COMMISSIONING ..............................6 4.1. POSITIONING ............................... 6 4.2. INITIAL CLEANING ............................7 4.3.
  • Page 3: Technical Parameters

    TECHNICAL PARAMETERS Model HEG788 HEG789 Fast cooling performance per cycle/kg 25Kg (+90°C/+3°C ) 50Kg (+90°C/+3°C ) Fast freezing performance per cycle/kg 15Kg (+90°C/-18°C) 30Kg (+90°C/-18°C ) Rated voltage 220-240V,50Hz 220-240V,50Hz Rated power (W) 1300 2500 Current (A) Auxiliary heater Safety climate class Room temperature 30℃...
  • Page 4: Introduction

    1.INTRODUCTION Please read instructions before using this appliance. IMPORTANT SAFETY INSTRUCTION To reduce the risk of fire, electric shock, or injury to persons when using the product, basic  safety precautions should be followed, including the following. This appliance must be properly installed and located in accordance with the Installation Instruction ...
  • Page 5: The Manufacturer Cannot Be Held Liable In The Following Cases

    Warning: Risk of fire / flammable materials The A-weighted emission sound pressure level not exceed 70 dB(A ) . For HEG788 only: The means for disconnection must be incorporated in the fixed wiring in accordance with current standards/legislation. Warning: Cabinets rated at 220-240V.
  • Page 6: Commissioning

    4.COMMISSIONING Carefully read the label on the equipment , do not cover for any reason whatsoever. and replace them immediately if damaged. Do not remove protection or panelling that require the use of tools. 4.1. POSITIONING Ensure that in respect of the dimensions, the space reserved for the equipment permits its correct utilisation and ease of maintenance .
  • Page 7: Initial Cleaning

    4.2. INITIAL CLEANING Before use all parts of the cabinet should be cleaned, For the walls and all internal parts use a suitable antibacterial detergent. For the plastic parts use a moistened cloth. Dry with a soft clean cloth. Use little or no water. Do not use harsh or abrasive solvents or detergents During cleaning do not approach bare-handed those parts which could cut (evaporator, condenser, etc.) and always use protective gloves .
  • Page 8: Usage For Carel

    6.USAGE FOR CAREL CONTROLLER 6.1. ACTION These devices are activated by one switches and an electronic control panel. 6.2. MEANING OF THE BUTTON...
  • Page 9: Selecting The Blast Chilling Cycle

    6.3. SELECTING THE BLAST CHILLING CYCLE...
  • Page 10: How To Access And Set Parameters

    6.4. HOW TO ACCESS AND SET PARAMETERS Type “F” (FREQUENT, not protected by password), Type “C” (CONFIGURATION, password protected) Step Action Effect Meaning Press PRG for 3 After 3 seconds the display will show the 1st parameter, Access to type ”F” parameters is direct seconds “0”(Password) without password...
  • Page 11: Directly Accessing The Parameters By Selecting The Category

    6.6. DIRECTLY ACCESSING THE PARAMETERS BY SELECTING THE CATEGORY The configuration parameters can also be accessed, in addition to the mode described above, via the category (see the icons and abbreviations in the table below), according to the list on the display with the corresponding name and icon.
  • Page 12: Usage For Dixell

    7.USAGE FOR DIXELL 7.1. QUICK REFERENCE GUIDE 7.1.1. KEYBOARD outside programming mode. Display target set point In programming mode operation. Push the key to set It selects A parameter or confirm an the Hds (UP) Start or stop a manual defrost. Short time pushing and releases to see the max.
  • Page 13: Meaning Of The Leds

    7.1.3. MEANING OF THE LEDS MODE Function Compressor enabled Anti-short cycle delay enabled ( Refer to “Ac” parameter) Flashing Defrost enabled Drip time in progress Flashing Fan enabled Fan delay after defrosting in progress Flashing An alarm is occurring Chiller cycle is working Chiller cycle Flashing Freeze cycle is working...
  • Page 14: Chilling\ Freezing Cycles

    7.2. CHILLING\ FREEZING CYCLES 7.2.1. HOW TO EDIT THE PARAMETERS OF A CHILLING/ FREEZING CYCLE Cycle programming is only possible with the instrument in stand-by ( no cycles active) . Select the cycle. The icons identify the cycles with the following correspondence: Soft Chilling Soft Freezing HD + CH...
  • Page 15: Manitenance

    8.MANITENANCE 8.1. PERIODIC CLEANING For hygiene reasons and improved performance, deep clean entire unit at least once a month, the internal basin. Paying close attention to the drain point., this needs to be kept clean, First perform a manual defrosting cycle ( paragraph 6/7), When complete, switch off the power supply and clean the inside following the instructions given in paragraph 4.2 (initial cleaning ).
  • Page 16: Trouble Shooting And Remedies

    9.TROUBLESHOOTING Often, the malfunction of a unit is due to simple causes which can easily be solved without contacting a technician .Therefore please try the following steps before contacting your service partner. 9.1. IF THE CABINET DOES NOT OPERATE, MAKE SURE THAT: - Check the fuse in the plug - The plug has been correctly inserted into the socket.
  • Page 17: Dismantling

    11.DISMANTLING The disposal of the cabinet needs to be performed by specialist company, licensed by the local authorities, and observing local statutes. Polyurethane foaming material, not fire-resistant, when handling the material, it should be according with local law, regulation and legislation. - The cabinet is constructed from the following: - Structure in stainless steel, - Electrical components and cables,...
  • Page 18: Energy Efficiency Parameters

    ENERGY EFFICIENCY PARAMETERS Model: HEG788 Type of product Blast chiller / Blast freezer Refrigerant Gas : R290 (Propane), GWP: 3 Indication of the program used for blast chilling Indication of the program used for blast freezing Value Item Symbol Unit...
  • Page 19 Chefmaster distributor or local authority responsible for waste disposal. Compliance All Arctica parts and products have under gone a stringent testing process to ensure that comply with all European standards and specifications. All Arctica products carry the CE approval symbol.