Asian Stanley International Co., Ltd.
●Installation of this product/ luminaire must be carried out by a qualified electrician in accordance with the national, local
electric and construction codes and regulations. Installation by unqualified person is prohibited by law.
Product Name
LLF0139A/LEN1/168/E/IN/A
LLF0139A/LEN1/144/E/IN/A
LLF0139A/LEN1/120/E/IN/A
Overall Dimensions
Maximum Projected area
IP classification
IK classification
Operation Temperature
Installation pole
Installation instructions
Attention at installation
WARNING
●Please ensure installation is in accordance with mounting instruction. Risk of product fall or fire.
●Do not use the product under the following environment and situation. It will cause electric shock and fire.
The unit will fall or not operate if not installed properly:
・Place exposed directly to organic solvent (Acetone, Ethyl ether, Hexane, etc.).
・Place where corrosive gas (Hydrogen sulfide, Chlorine, Ammonia, etc.)
and flammable gas (Hydrogen, Methane, etc.) is present.
・Places where flammable liquid (Gasoline, Kerosene, Fuel oil, etc.) is used.
・Places where humidity exceeds 90% or the product is affected by flood.
・Places covered by heat insulator and combustible material.
・Places where the product is buried under snow.
●Don't set it up in the place where the hazard is caused when the icicle drops. It causes the injury by the icicle fall.
●The insulation of the AC cable connected to the luminaire must be free from damage or cracks. -Risk of electric shock and fire.
●Do not disassemble this product, repair or replace any of its components. -Risk of electric shock, fire or the product fall.
●Do not use the product when broken or appears damaged in any way. -Risk of product fall, electric shock and fire.
●Please use the cable indicated on operation method with the performance beyond equality for a used cable.
It causes the electric shock, a fire, not lighting when other cables are used.
●When abnormality occurs, turn off the power immediately and contact your distributor for assistance. Continued use of
the product risks electric shock and fire.
●Do not connect to power source other than specified for the product. –Risk of electric shock, fire and product will not illuminate.
●Temper Glass may be damaged if a strong shock is applied.
Please be careful handing so that scratches will not be attached when carrying or installing the luminaire.
Instruction manual
Power
167W
140W
121W
Mount Height
Installer, please save a copy this instructions manual for retention and reference by the end user.
Incorrect handling of this product may cause serious personal injury, death and damage
to the product and property.
Road Light
Rated voltage
Rated Current
100Vac 1.69A
240Vac 0.72A
100Vac 1.41A
100~240Vac
240Vac 0.61A
100Vac 1.22A
240Vac 0.53A
For retention and reference
frequency
50/60Hz
734mm × 313mm × 151mm
0.198 m
2
IP66
IK08
-20~50℃
6~14m
Φ60.5mm (Length ≧135mm)
Control No. D00213286C
Weight
~10 kg
1/7

Advertisement

loading
Need help?

Need help?

Do you have a question about the LLF0139A/LEN1/168/E/IN/A and is the answer not in the manual?

Questions and answers

Summary of Contents for Stanley LLF0139A/LEN1/168/E/IN/A

  • Page 1 Asian Stanley International Co., Ltd. Control No. D00213286C Road Light For retention and reference Instruction manual ●Installation of this product/ luminaire must be carried out by a qualified electrician in accordance with the national, local electric and construction codes and regulations. Installation by unqualified person is prohibited by law.
  • Page 2 Control No. D00213286C There is a possibility that it is assumed to owe injury. CAUTION ●This product is IP 66. ●Wind pressure resistance is 60m/s. Risk of product fall. ●Be sure to turn off the power supply during product installation or removal. There is a possibility that the product is damaged when the installation or removal of the lighting is done with the power supply turned on.
  • Page 3: Installation Procedure

    Control No. D00213286C Installation procedure 1.Open cover Cover Latch Open Latch Open Top Cover Section : Housing Bolt / Screw Layout 2.Install pole by set screw M8. Recommended set screw M8 torque : 12.5 N·m 2.1 Move the Hexagonal Bolt M8 up. 2.2 Insert pole to Housing Bring the pole into contact with the pole stopper.
  • Page 4 Control No. D00213286C Electrical wire connection method 1.Install AC line cable to Cable gland by tightening the Cable gland. Recommended torque of Cable gland : 2.2 ~ 3.0 N·m Cable gland Requirement of input AC line cable ・Conductor of wire : 2.5 mm 3-Core : L(R/S/T), N, G ・Available cable sheath size : Φ6~Φ11mm AC line cable...
  • Page 5 Control No. D00213286C Electrical wire connection method 2.4) Assembly Terminal Block (Male) to Terminal Block (Female) by push together until tight. 2.5) Fix Block terminal with housing by using screw M3 Recommended screw M3 torque : 6.0 kgf・cm Block terminal (Female) Tighten by Screw M3 Assembly...
  • Page 6: Handling Notes

    Control No. D00213286C Installation instructions Dear customer, please retain this instruction manual. Handling notes Incorrect handling of this product may cause serious personal injury, death and/ or damage to the WARNING product and property. ●When servicing this luminaire, please strictly follow the instructions in the manual. ●Always turn OFF the power before performing and maintenance.
  • Page 7 ●For enquiry, please quote us the product model found on the label on the product. ●Our phone numbers printed in this manual may change. Please visit our homepage for the latest contact information. ASIAN STANLEY INTERNATIONAL CO.,LTD. 48/1 Moo 1 Kukwang Ladlumkaew, Pathumthanee 12140 Thailand TEL : +66 2 599 1260 スタンレー電気株式会社...

This manual is also suitable for:

Llf0139a/len1/144/e/in/aLlf0139a/len1/120/e/in/a