Siegenia DRIVE axxent HSA smart Assembly And Operating Instructions Manual
Siegenia DRIVE axxent HSA smart Assembly And Operating Instructions Manual

Siegenia DRIVE axxent HSA smart Assembly And Operating Instructions Manual

Table of Contents

Advertisement

Quick Links

ASSEMBLY AND OPERATING
INSTRUCTIONS
DRIVE
DRIVE axxent HSA smart
Partially concealed lift-slide drive
Window systems
Door systems
Comfort systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRIVE axxent HSA smart and is the answer not in the manual?

Questions and answers

Summary of Contents for Siegenia DRIVE axxent HSA smart

  • Page 1 ASSEMBLY AND OPERATING INSTRUCTIONS DRIVE DRIVE axxent HSA smart Partially concealed lift-slide drive Window systems Door systems Comfort systems...
  • Page 2: Table Of Contents

    Contents Contents GENERAL INFORMATION ......4 ASSEMBLY ..........12 1.1. Target.group.of.this.documentation ..... 4 7.1. Installation.requirements ......12 Intended use ..........4 Notes for mains cable running ....14 Improper use ..........4 7.3. Holes.and.milling.on.the.lift.&.slide.sash ..16 7.3.1. Positioning.and.adjustment.of.the.catch.jig.(acces- Dimensions ........... 4 sories) ..............16 7.3.2.
  • Page 3 Contents Concealed mains cable running and TEACHING.IN.THE.INTERMEDIATE.STOP.–. connection.–.scheme.A ....... 32 SCHEME C ..........48 7.7.1. Concealed.routing.and.connection.in.the.power. 12.1 Teaching in the primary sash....... 48 supply.for.slide.drive.SA.–.scheme.A ....32 7.7.2. Wiring.diagram.–.scheme.A ........ 32 12.2 Teaching in the secondary sash ....48 7.8. Assembly.of.the.light.curtain.–.scheme.A ... 33 OPERATION.–.SCHEME.C ......49 7.9.
  • Page 4 Contents RECTIFICATION OF MALFUNCTIONS ..59 17.1. Faults./.causes./.description.of.solution.DRIVE. axxent HSA smart ........59 17.2 SI Comfort app ..........60 TECHNICAL SPECIFICATIONS ....60 ACCESSORIES ..........61 EC DECLARATION OF INCORPORATION ..62 4/64 12.2021 H47.MOTS0007EN...
  • Page 5: General Information

    • The DRIVE axxent HSA smart.system.uses.an.electric.motor.to.open.and.close.windows.and.patio.doors.with. lift-slide.hardware.(e.g..PORTAL.HS). • The standard DRIVE axxent HSA smart system is not suitable for use in swimming pools and/or damp rooms. Special.designs.are.possible.and.permitted.only.upon.request.and.after.having.been.tested.by.SIEGENIA. • The DRIVE axxent HSA smart must only be operated with hardware components and genuine accessories from SIEGENIA.
  • Page 6: Safety Notes

    • All-pole.safety.isolation.is.required.when.the.mains.cable.is.routed.on.site.because.the.power.supply.does. not.have.a.separate.power.cut-off.switch. • Connect.in-wall.supply.lines.to.the.DRIVE axxent HSA smart HS system in branch boxes. These branch boxes must be kept accessible for maintenance. • When.cleaning.the.lift.&.slide.sash.and.the.drives,.make.sure.that.no.liquid.gets.inside.the.DRIVE axxent HSA smart HS system as this could damage the electronics.
  • Page 7: Device Functions

    • The DRIVE axxent HSA smart.can.be.controlled.by.a.tablet.or.smartphone.and.offers.additional.device. functions.via.the.SI.SIEGENIA.Comfort.app..Please.follow.the.enclosed.quick.start.instructions.(H47. MOTS005EN). • The.slide.drive.SA.features.an.electronic.cut-off.function.(see.“3.3.Information.on.safety.cut-off.and.jam. protection”.on.page.8). • To.further.increase.safety.during.travel,.the.slide.drive.SA.with.terminal.board.allows.for.the.integration. of.a.light.curtain..If.an.object.is.moved.into.the.path.of.the.lift.&.slide.sash,.the.lift.&.slide.sash.is.stopped. immediately. • In.the.event.of.a.power.failure,.the.DRIVE axxent HSA smart can be operated manually using the emergency operating.key. • The.lift.&.slide.sash.can.be.moved.into.a.freely.programmed.intermediate.position.(intermediate.stop). • The.lift.&.slide.sash.can.be.moved.into.a.secured.night.vent.position.(only.the.PORTAL.HS). 3.2 Control The DRIVE axxent HSA smart.system.offers.the.following.control.options: radio remote end.position.of.the.lift.
  • Page 8: Led Indicator

    DRIVE axxent HSA smart DRIVE Device.functons PORTAL HS 3.3 Informaton.on.safety.cut-off.and.jam.protecton General.informaton.on.safety.cut-off As.soon.as.the.path.of.a.lift.&.slide.sash.becomes.blocked.(e.g..due.to.an.obstacle.or.because.it.is.stuck),.it.stops,. moves.for.approx..4.seconds.in.the.opposite.direction.and.then.comes.to.a.final.stop.(see.figure.below). For.increased.safety.in.the.area.around.the.bottom.shear.points.between.the.lift.&.slide.sash.and.the.HS.frame,.in. normal.motor-powered.operation,.the.lift.&.slide.sash.only.moves.as.far.as.a.defined.opening.position.. Lift.&.slide.sash.moves..hits an obstacle and stops..then.moves.for.approx..4.seconds. in.the.opposite.direction.and.stops Safety.shutdown.in.systems.with.light.curtain If.additional.safety.requirements.apply,.the.optional.terminal.board.must.be.ordered..Also.available.prepared.to. be.equipped.with.a.light.curtain..To.prevent.injuries.and.damage,.the.safety.cut-off.function.is.activated,.which. causes.the.lift.&.slide.sash.to.stop.immediately..If.equipped.with.a.light.curtain,.the.lift.&.slide.sash.is.opened.fully. to its stop. Lift.&.slide.sash.moves..an.object.moves.into.the.safety.zone... Lift.&.slide.sash.stops 3.4 LED.indicator The.LED.is.attached.to.the.lower.edge.of.the.slide.drive.SA..Please.note.the.light.indicators.in.the.LED..The. indicators.and.their.meanings.are.listed.in.the.table.below: functon.and.meaning Program flashes.red...
  • Page 9: Size Range

    DRIVE axxent HSA smart DRIVE Size.range PORTAL HS Size.range Scheme.A Scheme.C Inside.frame.width.(RIB).size.1 2144.mm.–.2794.mm 4284.mm.–.5584.mm Inside.frame.width.(RIB).size.2 2795.mm.–.4099.mm 5585.mm.–.8194.mm Inside.frame.width.(RIB).size.3 4100.mm.–.6666.mm 8195.mm.–.13328.mm Sash height .(standard.for.PORTAL.HS) 1175.mm.–.2675.mm 1175.mm.–.2675.mm Sash weight DRIVE axxent HSA 200 max. 200 kg max. 200 kg Sash weight DRIVE axxent HSA 400 max.
  • Page 10: Basic Hardware

    DRIVE axxent HSA smart DRIVE Basic.hardware PORTAL HS Basic.hardware 5.1 Hardware.components AN LEI TUN MO NTA GE D R I V E sm art ent HS A DR IVE axx Fenst ersyst Türsy steme Komf ortsy steme 10/64 12.2021 H47.MOTS0007EN...
  • Page 11: Hardware List

    DRIVE axxent HSA smart DRIVE Basic.hardware PORTAL HS 5.2 Hardware.list Number.of. Size.by.slide.drive Size.range.in.mm Colour pieces DRIVE axxent HSA smart Scheme.A,.size.1.(one.slide.drive.each.on.left.or.right) 2144.–.2794 Scheme.A,.size.2.(one.slide.drive.each.on.left.or.right) 2795.–.4099 Scheme.A,.size.3.(one.slide.drive.each.on.left.or.right) 4100.–.6666 White RAL 9003 Silver.RAL.9006 Scheme.C,.size.1.(one.slide.drive.each.on.left.and.right) 4284.–.5584 Scheme.C,.size.2.(one.slide.drive.each.on.left.and.right) 5585.–.8194 Scheme.C,.size.3.(one.slide.drive.each.on.left.and.right) 8195.–.13328 Number. of.pieces. Item Contents.of.slide.drive.SA.carton Version scheme –...
  • Page 12: On-Site.risk.and.hazard.analysis

    • Type of access control • Requirements.for.added.safety.can.be.met.with.a.light.curtain 6.2 Notes.for.assembly.and.installaton • Use.flexible.supply.lines.(route.conduit.tubes.if.necessary) • When.routing.cables,.avoid.damaging.the.cables.by.crushing,.bending.or.stretching.them • The concealed mains supply lines running to the DRIVE axxent HSA smart must be connected in branch boxes.(these.branch.boxes.must.be.easily.accessible.for.maintenance) • Protect the DRIVE axxent HSA smart.system.against.contamination.by.site.material.and.humidity • The.hardware.components.must.be.securely.fixed.in.place • Connect.to.the.mains.supply.only.after.you.have.tested.for.proper.mechanical.function •...
  • Page 13: Cooperation.between.trades.and.interfaces

    Assembly 7.1 Installaton.requirements General.informaton.about.installaton • The.following.description.of.the.assembly.process.is.a.recommendation.from.SIEGENIA and describes the major.steps.involved..The.specific.details.of.the.assembly.process.are.determined,.amongst.other.factors,. by.the.HS.element.used,.by.the.production.process.and.by.the.window.manufacturer's.equipment.and. facilities. • You.will.find.specific.steps.for.installation.of.the.DRIVE axxent HSA smart.on.our.download.portal: downloads.siegenia.com/en/00007/index.html Tools.required.(not.included.in.scope.of.delivery) • Drill • Ø.3.mm,.Ø.7.mm,.Ø.10.mm,.Ø.15.mm.plus.Ø.20.mm.timber.or.metal.drill • Phillips.screwdriver.(size.2) • 1.screwdriver.bit.90.mm.long. • 2 screw clamps • Folding rule • Router.(for.timber.elements) • Between 2 and 4 assembly racks •...
  • Page 14 DRIVE axxent HSA smart DRIVE Assembly PORTAL HS Risk.of.mechanical.defects.if.the.DRIVE axxent HSA smart.system.is.put.into.operaton. unassembled. • You must assemble the DRIVE axxent HSA smart.first.before.putting.it.into.operation! Requirements.to.be.met.by.the.lift.&.slide.sash: • the.lift.&.slide.sash.must.not.be.warped. • The.lift.&.slide.sash.must.be.installed.vertically.plumb.in.the.reveal. • The.threshold.must.be.properly.and.sufficiently.supported.—.especially.for.wide.or.heavy.HS.elements.(e.g.. 400 kg). • The displacement force must not be > 60 N.
  • Page 15: Notes For Mains Cable Running

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.2 Notes.for.mains.cable.running Important.informaton.for.safety.and.assembly The.fitting.of.the.mains.cable.is.determined.by.the.prevailing.conditions.on.site..There.are.two.assembly.options: assembly.opton.1.–.surface-mounted.mains.cable.running: the DRIVE axxent HSA smart.system.is.delivered.as.standard.with.a.mains.cable.. The cable outlet for scheme A is always.at.the.top.of.the.slide.drive.SA.on.the.locking.side.(fig..1);.for.scheme.C,.it.can.be.located.on.the.outside. of.the.slide.drive.SA.on.either.the.LH.or.the.RH.side..A.notch.for.the.cable.outlet.must.be.made.on.the.cover. cap.SA.of.the.cover.profile.SA.(see.Fig..2)..A.suitable.mains.socket.must.be.located.near.the.cable.outlet..It.is. recommended.to.route.the.mains.cable.through.an.appropriate.installation.duct. H47.MOTS0007EN 12.2021 15/64...
  • Page 16 DRIVE axxent HSA smart DRIVE Assembly PORTAL HS assembly.opton.2.–.concealed.mains.cable.running If.the.customer.is.responsible.for.the.concealed.routing.of.the.mains.cable.for.the.slide.drive.SA.and.the. connection.of.the.slide.drive.SA.(for.scheme.A.in.the.power.supply,.for.scheme.C.in.the.5-pin.socket),.this.work. must.be.carried.out.by.a.qualified.electrician..When.running.mains.cables.for.HS.elements.which.have.not.yet. been.installed.(e.g..new.build.and.renovation.projects),.a.flexible.cable.(5.x.1.5.mm .incl..connection).for.buttons. (not.included.in.scope.of.delivery).must.be.provided.by.the.customer.and.fed.concealed.through.the.top.section. of.the.HS.frame.(Fig..3). Holes.for.the.cable.inlet.and.outlet.(each.approx..Ø.10.mm).must.be.made.for.this.purpose,.with.the.centre.of. each.hole.being.positioned.approx..7.mm.away.from.the.inside.frame.edge.(Fig..4)..All-pole.safety.isolation.is. required.if.the.customer.is.routing.the.mains.cable..The.isolated.end.of.the.mains.cable.must.be.located.inside. the.power.supply.housing.(scheme.A).or.5-pin.socket.(scheme.C)..The.connection.to.the.slide.drive.is.made. in.accordance.with.the.wiring.diagrams..In.the.mounting.angle.for.the.slide.drive.SA,.there.is.a.sufficiently. dimensioned.recess.for.the.cable.outlet.on.the.HS.frame.profile.for.scheme.A.(Fig..5)..The.mounting.angle.for. scheme.C.does.not.have.a.recess.for.the.cable.outlet.(Fig..6)..Concealed.mains.cable.running.to.the.slide.drive.SA. is through the top edge of the frame on the locking side 7 mm Bottom.edge.of.HS.frame.(without.cover) Dimension.Y.=.15.mm.for.timber.and.PVC.elements Inside frame Dimension.Y.=.central.in.relation.to.hollow.section.in.
  • Page 17: Holes.and.milling.on.the.lift.&.Slide.sash

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.3 Holes.and.milling.on.the.lift.&.slide.sash 7.3.1 Positoning.and.adjustment.of.the.catch.jig.(accessories) Place.the.jig.horizontally.at.the.top.of.the.lift.&.slide.sash.(Fig..1),.removing.existing.sash.sealings.first..Position.and. set.the.jig.in.accordance.with.the.dimensioning.(Fig..2).. Make.the.holes.for.the.catch.horizontally.at.the.top,.noting.the.drilling.diameter.(Fig..3). Positioning.and.drilling.diameters.for.the.holes.of.the.catch.on.the lift.&.slide.sash.(Fig..for.timber.profile.DIN.left.–.DIN.right.is.a.mirror.image) (416) Adjustment.dimension.X Cable.feed-through.Ø.15 Supporting.peg Catch base Ø 7 Screw.holes.Ø.3 10,5 - 0,2 Hole Ø 3 for.fixing.screws for catch Hole Ø 7 Hole Ø 15 for.supporting.peg.for...
  • Page 18: Through.hole.for.cable.channel.in.lift.&.Slide.sash

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.3.2 Through.hole.for.cable.channel.in.lift.&.slide.sash Timber.elements.require.a.through.hole.(Ø.15.mm).for.the.cable.channel.in.the.sash.groove.in.the.top.corner.of. the.lift.&.slide.sash.on.the.locking.side..This.hole.is.created.by.pre-drilling.to.Ø.10.mm.with.a.drill.180.mm.long. and.then.finish-drilling.to.Ø.15.mm.(Fig..5.and.6).. The.through.hole.can.be.drilled.with.the.through.hole.jig.(see.fig..6) (see.accessories,.page.61). Through.holes.do.not.have.to.be.drilled.for.HS.PVC.and.aluminium.profiles..If.necessary,.the.slider.support.can.be. machined to accommodate the cable channel Positioning.and.drilling.dimensions.on.the.lift-slide.sash (Fig..for.timber.profile.DIN.left.-.DIN.right.is.a.mirror.image) Through.hole.Ø.15.(for.cable.feed-through) Through hole Use 180 mm long drill to.pre-drill.to.Ø.10 then.finish-drill.to.Ø.15 18/64 12.2021 H47.MOTS0007EN...
  • Page 19: Holes.for.one-Button.operation.lift.drive.(Profile. Exemplary)

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.3.3 Holes.for.one-button.operaton.lift.drive.(profile.exemplary) Use.the.lift.drive.jig.PAFB0020.to.drill.the.holes. Ø 2 Ø 20 Align.the.jig.to.the.respective.stop 18.5 Plug.Attach.cotter.pins.into.profile-related.dimension.„A“ drilling.depth.to.eurogroove Bottom.edge.of.the.sliding.sash H47.MOTS0007EN 12.2021 19/64...
  • Page 20: Hole.dimension.table.profiles

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.3.4 Hole.dimension.table.profiles Profile Dimension A Dimension B Gealan S8000 standard 1265 Gealan.S8000.barrier-free 1255 Gealan S9000 standard 1264 Gealan.S9000.barrier-free 1254 Gealan S9000 Design standard 1264 Gealan.S9000.Design.barrier-free 1254 Rehau Synego standard 1258 Rehau.Synego.barrier-free 1253...
  • Page 21 DRIVE axxent HSA smart DRIVE Assembly PORTAL HS Profile Dimension A Dimension B Aliplast Ultraglide 1266 Aliplast Ultraglide Monorail 1266 Alutech Alt SL 160 1265 Wicona WSL 160 1265 Aluprof.MB-77.HS.HI 1263 Gastaldello EL170 S 1264 DecAlu 163Slide 1264 AluK.S141 1264 AluK.Koloss...
  • Page 22: Millings For Motorised Gear Axxent Shg Scheme A (Profile.exemplary)

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.3.5 .Millings.for.motorised.gear.axxent.SHG.scheme.A.(profile.exemplary) frame Sliding.sash Gear size Gear size 1540 1546 1840 1846 18.5 18.5 Upper edge of running rail *Millings.are.only.exemplary;.for.details.see.profile-dependent.assembly.instructions 22/64 12.2021 H47.MOTS0007EN...
  • Page 23: Milling For Motorised Gear Axxent Rgb Scheme A (Profile.exemplary)

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.3.6 Milling.for.motorised.gear.axxent.RGB.scheme.A.(profile.exemplary) frame Gear size 1540 1840 18.5 18.5 Upper edge of running rail *Additional.locking.parts.can.be.inserted.at.the.top.as.centre.lock.. For.details.see.profile-dependent.assembly.instructions H47.MOTS0007EN 12.2021 23/64...
  • Page 24: Millings For Motorised Gear Axxent Rgb Scheme C (Profile.exemplary)

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.3.7 Millings.for.motorised.gear.axxent.RGB.scheme.C.(profile.exemplary) 18.5 24/64 12.2021 H47.MOTS0007EN...
  • Page 25: Cable.routing

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.4 Cable.routng 7.4.1 Fixing.the.cable.for.lift.drive.HA 1. Connect.the.cable.to.the.lift.drive.HA. 2. Thread the cable into the cable channel on the gear. 3. The.cable.can.also.be.fixed.with.adhesive.tape.if.necessary. H47.MOTS0007EN 12.2021 25/64...
  • Page 26: Guiding.the.cable.through.the.gear.profile.and.fixing.it.with.cable.holders

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.4.2 Guiding.the.cable.through.the.gear.profile.and.fixing.it.with.cable.holders To.avoid.damaging.the.cable,.the.following.information.must.be.heeded: • cable.must.be.free.from.moving.parts.and.must.not.be.clamped • Sharp.edges,.in.particular.on.aluminium.elements,.must.be.deburred. 1. Clip.cable.holders.into.gear.profile 2. Split.the.6-wire.flat.ribbon.cable.into.sections.of.3.wires.and.push.into.the.cable.holders Attenton! The cable holders must be aligned with the screw holes and the locking bolt 3. Clip.in.distance.pieces.above.and.below.the.cable.holders.(only.for.PVC.and.aluminium.elements). 26/64 12.2021 H47.MOTS0007EN...
  • Page 27: Preparing.for.cable.installation.in.the.sash.groove. At The Top

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.4.3 Preparing.for.cable.installaton.in.the.sash.groove.at.the.top Important.note:.with.some.profiles.with.guiding.rail.at.the.top,.the.cable.holders.can.rub.against.the.guiding.rail. when.the.lift.&.slide.sash.is.lifted..Actions.for.avoiding.this.are.described.below: tmber.elements • for.timber.profiles.with.guiding.rail.HH.0130-01/-02,.the.cable.can.be.routed.through.the.glazing.rebate. • Alternatively,.the.sash.groove.can.be.milled.5.mm.deeper.on.the.horizontal.sash.timber.at.the.top. The.bearing.surface.of.the.guides.must.not.be.altered! • In.the.case.of.retrofitting,.flat.washers.(Ø.20.mm).and.nails.(max..30.mm.long).must.be.used.to.secure.the. cable.in.the.sash.groove.at.the.top.(see.Fig..1)..Care.must.be.taken.to.avoid.damaging.the.wires.of.the.cable. with the nails. Timber.element.with.guiding.rail.HH.0130-01/-02 Nail.(max..30.mm.long) Flat.washer.(Ø.20.mm) Flat.ribbon.cable.(6-wire) obere Führungsnut Sash.groove.at.top PVC elements With.certain.PVC.profiles.(see.Chapter.4),.the.webs.of.the.cable.holders.must.be.removed.(e.g..with.pliers.or. similar,.see.Fig..2) H47.MOTS0007EN 12.2021 27/64...
  • Page 28 DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.4.4 Cable.routng.in.top.the.sash.groove Proceed.as.follows.when.routing.the.cable.in.the.lift.&.slide.sash: • run.the.cable.in.the.sash.groove.at.the.top.as.far.as.the.cable.outlet.hole.(Fig..1.and.2). • Insert.the.cable.into.the.cable.feed-through.on.the.catch.base.(Fig..3).and.pull.back.as.far.as.a.length.of.50. mm.(Fig..5). • Place.the.catch.base.and.if.applicable.the.packer.(depending.on.profile,.included.in.scope.of.delivery).on.the. sash.(Fig..4). • Use.cable.holders.to.secure,.loop.and.fix.the.cable.in.the.sash.groove.at.the.top.(Fig..6). • If.a.central.lock.is.being.used.in.the.HS.hardware,.provision.may.need.to.be.made.for.a.sufficiently. dimensioned.side.recess.for.the.cable.channel.in.the.sash.groove.at.the.top Plug connector for slide.drive.SA Packer (depending.on.profile) 28/64 12.2021 H47.MOTS0007EN...
  • Page 29: Assembly.of.lift.drive.ha

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.5 Assembly.of.lift.drive.HA 7.5.1 Installaton.of.the.button 7.5.2 Inserton.of.gear H47.MOTS0007EN 12.2021 29/64...
  • Page 30: Assembly.of.the.slide.drive.sa.-.Scheme.a

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.6 Assembly.of.the.slide.drive.SA.–.scheme.A 7.6.1 Horizontal.positoning.of.the.slide.drive.SA.-.scheme.A When.measuring.the.RIB.(inside.frame.width),.take.into.account.whether.the.HS.frame.profile.is.being.used.with. or.without.a.cover..With.a.cover,.the.inside.frame.edge.is.offset.inwards.and.must.be.taken.into.account.when. measuring.the.RIB..The.offset.specified.here.of.2.mm*.corresponds.to.the.material.thickness.of.the.side.cover.cap. Opton.A.—.HS.frame.profile.without.cover Position.slide.drive.SA.offset.from.inside.frame.edge.by.2.mm*.(see.Fig..A) 2 mm* Fig..for.positioning.DIN.left.(DIN.right.is.a.mirror.image) Inside frame edge External edge mounting.angle Inside.frame.edge slide.drive.SA Cover.cap.SA 2 mm* 2 mm* Cowl length Opton.B.—.HS.frame.profile.with.cover On.a.HS.frame.profile.with.cover,.the.inside.frame.edge.is.not.visible.through.the.cover..The.slide.drive.SA.must.be. positioned.offset.from.the.inside.frame.edge.by.2.mm*.(see.Fig..B)..To.achieve.this,.the.distance.from.the.inside. frame.edge.to.the.external.edge.of.the.cover.must.be.measured.out.before.positioning.the.slide.drive.SA. 2 mm* Fig..for.positioning.DIN.left.(DIN.right.is.a.mirror.image)
  • Page 31: Vertical.positioning.and.fixing.of.the.slide.drive.sa. -.Scheme.a

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.6.2 Vertcal.positoning.and.fixing.of.the.slide.drive.SA.-.scheme.A Two.screw.levels.(A.or.B).are.provided.to.fix.the.slide.drive.SA.to.the.top.of.the.HS.frame.profile..You.will.find. specific.steps.for.installation.of.the.DRIVE axxent HSA smart.on.our.download.portal: downloads.siegenia.com/en/00007/index.html 1. Fixing.the.slide.drive.SA.to.the.mounting.angle.at.screw.level.A.or.B. 2. Position.the.catch.on.the.catch.base.and.screw.on.with.suitable.screws. 3. Connect.the.sash.cable.(flat.ribbon.cable,.6-wire).and.cable.energy.supply.chain.with.the.plug.socket..Do.not. crush the cable. 4. Attach.the.cover.cap.for.the.catch..Ensure.that.the.cable.is.correctly.positioned,.it.must.not.be.raised. 5. Attach.the.cover.profile.SA.to.the.mounting.angle. 6. Push.the.RH.and.LH.cover.caps.SA.onto.the.cover.profile.SA Inside.frame.edge Screw.levels Plug.connections H47.MOTS0007EN 12.2021 31/64...
  • Page 32: Concealed Mains Cable Running And

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.7 Concealed.mains.cable.running.and.connecton.–.scheme.A 7.7.1 Concealed.routng.and.connecton.in.the.power.supply.for.slide.drive.SA.–.scheme.A Important.note:.if.the.customer.is.responsible.for.routing.the.flexible.mains.cable.(5.x.1.5.mm ) for the slide drive.SA.and.the.connection.in.the.power.supply.of.the.slide.drive.SA,.this.work.must.be.carried.out.by.a.qualified. electrician. Risk.of.overheatng! Danger.of.electrical.shock! • Prior.to.installation,.you.must.disconnect.the.mains.cable.from.the.AC.mains.power.supply.or.disconnect. the mains fuses. With.concealed.mains.cable.running.and.for.control.using.a.wall.or.key.switch.(not.included.in.scope.of.delivery),. the.cable.must.be.connected.in.the.power.supply.of.the.slide.drive.SA. 1. Unscrew.the.fixing.screws.on.the.power.supply.cover.and.remove.the.power.supply.cover. 2. Disassemble.and.remove.the.plug.cable.that.comes.standard.in.the.power.supply. 3. Run.the.concealed.mains.cable.through.the.cable.outlet.in.the.mounting.angle.and.into.the.power.supply. housing;.the.jacket.on.the.mains.cable.must.extend.into.the.power.supply.housing..The.mains.cable.must.be. isolated.inside.the.power.supply.housing: cover.bracket power.supply.cover Disassemble.and.remove. run the concealed mains cable...
  • Page 33: Assembly.of.the.light.curtain.-.Scheme.a

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.8 Assembly.of.the.light.curtain.–.scheme.A Alteratons.must.be.made.to.the.DRIVE axxent HSA smart.in.order.to.operate.it.with.a.light.curtain The.suitable.light.curtain.can.be.ordered.from:. Light curtain CEDES GmbH Elektronische Systeme Elzmatten.6 D-79365.Reinhausen Light curtain Terminal.board.for.connectng.light.curtain.(plugs.or.terminals) Recipient Recipient Transmitter Transmitter inside outside inside outside + 24 V Input light curtain 2...
  • Page 34: Assembly.of.the.slide.drive.sa.-.Scheme.c

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.9 Assembly.of.the.slide.drive.SA.–.scheme.C 7.9.1 Horizontal.positoning.of.the.slide.drive.SA.-.scheme.C Both.slide.drives.must.be.assembled.dead.centre.between.the.two.sash.join.edges..The.two.mounting.angles.must.be. positioned.next.to.each.other.(Fig..2.and.3)..The.two.power.supplies.are.then.located.inside,.one.opposite.the.other. Checking.the.inside.frame.width.(RIB).–.scheme.C When.measuring.the.RIB.(inside.frame.width),.take.into.account.whether.a.HS.frame.profile.is.being.used.with. or.without.a.cover..With.a.cover,.the.inside.frame.edge.is.offset.inwards.and.must.be.taken.into.account.when. measuring.the.RIB..Each.RIB.must.be.calculated.individually,.for.the.left-hand.slide.drive.SA.(dimension.1) and the right-hand.slide.drive.SA.(dimension.2). To.check.that.the.measurement.has.been.taken.correctly,.measure.the.total.RIB.(dimension.A). The dimension A must.match.the.total.resulting.from.adding.RIB.dimension.1 to RIB dimension 2.(Fig..1). A.=.RIB.(measure.with.cover Dimension 1.=.inside.frame.edge Dimension 2.=.inside.frame.edge as.far.as.centre.of.sash.join.edge as.far.as.centre.of.sash.join.edge Cableoutlet Cable outlet (can.be.selected)
  • Page 35: Vertical.positioning.and.fixing.of.the.slide.drive.sa. 13.2. -.Scheme.c

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.9.2 Vertcal.positoning.and.fixing.of.the.slide.drive.SA.-.scheme.C Drilling.holes.on.two.screw.levels.(A.or.B).are.provided.to.fix.the.slide.drive.SA.to.the.top.of.the.HS.frame.profile.. The.slide.drive.is.positioned.and.screwed.on.as.appropriate.for.the.installation.location.of.the.HS.profile.system. concerned..You.will.find.specific.steps.for.installation.of.the.DRIVE axxent HSA smart.on.our.download.portal: downloads.siegenia.com/en/00007/index.html 1. Fixing.the.slide.drives.SA.to.the.mounting.angle.at.screw.level.A.or.B. 2. Position.the.catch.on.the.catch.base.and.screw.on.with.suitable.screws. 3. Connect.the.sash.cable.(flat.ribbon.cable,.6-wire).and.cable.energy.supply.chain.with.the.plug.socket..Do.not. crush the cable Screw.levels Plug.connections Profile.connector H47.MOTS0007EN 12.2021 35/64...
  • Page 36 DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 4. Attach.the.cover.cap.for.the.catch. 5. Connect.the.plug.to.the.5-pin.socket.and.plug.the.connection.cable.(4-pin).into.the.circuit.board. 6. Use.cable.binders.to.fix.the.cable.to.the.power.supply.housing 7. Attach.the.cover.profile.SA.to.the.mounting.angle.. 8. Use.profile.connectors.to.connect.the.cover.profiles.on.the.left.and.right.at.and.above.total.length.of.7000.mm. Press.down.on.the.cover.profiles.so.that.they.snap.in.on.the.mounting.angle. 9. Push.the.RH.and.LH.cover.caps.SA.onto.the.cover.profile.SA HS sash edge HS sash edge Connection.cable. circuit board Plug 5-pin.socket 36/64 12.2021 H47.MOTS0007EN...
  • Page 37 DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.10 Concealed.mains.cable.running.and.connecton.–.scheme.C Concealed.routng.and.connecton.in.the.power.supply.for.slide.drive.SA.–.scheme.C Important.note:.if.the.customer.is.responsible.for.routing.the.flexible.mains.cable.(5.x.1.5.mm ) for the slide drive.SA.and.the.connection.in.the.power.supply.of.the.slide.drive.SA,.this.work.must.be.carried.out.by.a.qualified. electrician. Risk.of.overheatng! Danger.of.electrical.shock! • Prior.to.installation,.you.must.disconnect.the.mains.cable.from.the.AC.mains.power.supply.or.disconnect. the mains fuses. With.concealed.mains.cable.running.and.for.control.using.a.wall.or.key.switch.(not.included.in.scope.of.delivery),. the.cable.must.be.connected.in.the.5-pin.socket.of.the.slide.drive.SA. 1. Unscrew.the.fixing.screws.on.the.5-pin.socket.and.pull.out.the.plug. 2. Unplug.and.remove.the.2-wire.mains.plug.cable.that.comes.as.standard.in.the.power.supply. 3. Route.the.concealed.mains.cable.through.the.open.cable.duct.(clips.open.and.shut).and.cable.duct.recess.into. the.5-pin.socket..The.isolated.part.of.the.mains.cable.must.be.located.inside.the.5-pin.socket: Plug.to.5-pin.socket unplug.and.remove Concealed mains cable 5-pin.socket Plug connect.and.fix...
  • Page 38: Assembly.of.light.curtain.-.Scheme.c

    DRIVE axxent HSA smart DRIVE Assembly PORTAL HS 7.11 Assembly.of.light.curtain.–.scheme.C Alteratons.must.be.made.to.the.DRIVE axxent HSA smart.in.order.to.operate.it.with.a.light.curtain The suitable light curtain can be ordered Light curtain from:. CEDES GmbH Elektronische Systeme Elzmatten.6 D-79365.Reinhausen Light curtain Terminal.board.for.connectng.light.curtain.(plugs.or.terminals) Recipient Recipient Transmitter Transmitter inside outside inside...
  • Page 39: Finalising The Assembly

    Checking.the.functionality.of.the.HS.element.manually.with.the.DRIVE axxent HSA smart system installed So.that.friction.and.resistance.can.be.identified.during.manual.operation.of.the.lift.&.slide.sash,.the.slide.drive. should.be.decoupled.from.the.sash..To.do.this,.simply.release.the.catch.on.the.slide.drive.SA.from.the.catch.base. on.the.lift.&.slide.sash.and.pull.out.the.plug.of.the.connection.cable.for.the.lift.drive.HA.in.the.slide.drive.SA. Possible.causes.of.malfunctons.affectng.the.DRIVE axxent HSA smart • Changes to the HS element following assembly of the DRIVE axxent HSA smart.(e.g..changes.to.stoppers,. end.pieces,.etc.) • Seals.on.HS.element.too.stiff.or.not.fitted.correctly • Seal lip is rubbing against the guiding rail • During.travel,.the.cable.holders.in.the.sash.groove.at.the.top.are.rubbing.against.the.guiding.rail •...
  • Page 40: Commissioning.-.Scheme.a

    DRIVE axxent HSA smart DRIVE Commissioning.–.scheme.A PORTAL HS Commissioning.–.scheme.A 8.1 General.notes.for.commissioning • Following.installation.of.the.DRIVE axxent HSA smart.(initial.commissioning),.you.must.carry.out.a.reference. run.as.well.as.a.calibration.and.teach-in.run. • The.reference.run,.as.well.as.the.calibration.and.teach-in.run.help.to.determine.the.size.of.the.lift.and.slide. element and the displacement force. • The.reference.run.must.be.performed.again.in.the.event.of.a.power.failure..The.calibration.and.teach-in.run. only.has.to.be.performed.when.commissioning.the.equipment. • Any.tasks.relating.to.commissioning.may.only.be.completed.by.qualified.professionals. 8.2 Reference.run 1. Press.reset.button.(a).or.break.the.electric.circuit.and.then.reconnect.the.power.supply.(b) 2. Move.lift.&.slide.sash.into.“Close”.position.(manually.if.necessary) 3. Press.button.on.the.lift.drive.(c) 4. The.lift.&.slide.sash.is.automatically.lowered,.lifted.and.lowered/locked.during.the.reference.run.(d). Note:.the.LED.flashes.red.during.the.reference.run.(e).
  • Page 41: Calibration.and.teach-In.run

    DRIVE axxent HSA smart DRIVE Commissioning.–.scheme.A PORTAL HS 8.3 Calibraton.and.teach-in.run Risk.of.injury!.Hands,.arms,.legs.and.feet.can.get.trapped.and/or.crushed!.There.is.no. safety.cut-off.functon! • During.the.calibration.and.teach-in.run,.maintain.a.safe.distance.from.the.moving.elements. Risk.due.to.incorrect.measured.values! • To.prevent.incorrect.measured.values,.never.interrupt.or.interfere.with.the.calibration.and.teach-in.run.of. the DRIVE axxent HSA smart.system! 1. Move.lift.&.slide.sash.into.“Close”.position.(manually.if.necessary) 2. Press.the.“PROG”.button.(a) Note:.the.LED.flashes.green.(b). 3. Press.the.button.on.the.lift.drive.for.11.seconds.(c) Note:.while.the.button.is.pressed,.the.following.tones.sound.in.succession: 1.short.alarm.signal,.2.short.alarm.signals,.3.short.alarm.signals,.4.short.alarm.signals..Then.release.the.button. 4. Press.the.button.on.the.lift.drive.for.2.seconds.(d) Note:.while.the.button.is.pressed,.1.short.alarm.signal.is.sounded..Then.release.the.button. 11 sec. 2 sec. Positons.of.the.calibraton.and.teach-in.run 1. The.lift.&.slide.sash.unlocks.and.moves.as.far.as.the.end.position.stop.
  • Page 42: Teaching.in.the.intermediate.stop

    DRIVE axxent HSA smart DRIVE Teaching.in.the.intermediate.stop.–.scheme.A PORTAL HS Teaching.in.the.intermediate.stop.–.scheme.A Press.and.hold.down.button.for.8.seconds Press."PROG". LED.flashes. button green ..Press.button.to.the.required..lift.&.slide.sash.stops.and. position.is.saved..Press.position.1.x.briefly..lift.&.slide.sash.unlocks. and.starts.to.move... 42/64 12.2021 H47.MOTS0007EN...
  • Page 43: Operation.-.Scheme.a

    DRIVE axxent HSA smart DRIVE Operaton.–.scheme.A PORTAL HS 10 Operaton.–.scheme.A 10.1 “Open”.-.“Stop”.-.“Lock”.operaton Every.time.the.button.is.pressed,.the.function.switches.between.“Open”.-.“Stop”.-.“Lock”. Note:.the LED lights up green when opening. The LED lights up red when closing and locking. Press.1.x.briefly Press.1.x.briefly Press.1.x.briefly Lift.&.slide.sash.stops. Lift.&.slide.sash.closes. Lift.&.slide.sash. and locks. opens ... 10.2 10-min..night.vent.positon The.lift.&.slide.sash.moves.to.the.night.vent.position.and.lowers..After.10.minutes,.the.lift.&.slide.sash.
  • Page 44 DRIVE axxent HSA smart DRIVE Operaton.–.scheme.A PORTAL HS 10.4 Special.functon.“Opening.as.far.as.the.end.positon”.(stop) For.safety.reasons,.the.lift.&.slide.sash.does.not.open.fully.in.normal.motor-powered.operation. To.move.the.lift.&.slide.sash.to.its.absolute.end.position.(as.far.as.the.stop),.it.can.be.pushed.open.manually.or. moved.to.the.end.position.by.pressing.the.button.on.the.lift.drive..The.lift.&.slide.sash.must.be.in.the.“Open”. position. Press.1.x.briefly Press.button.and.hold.down..Lift.&.slide.sash.opens.further... Lift.&.slide.sash.opens..release.the.button.when.the.lift.&.slide..Lift.&.slide.sash.stops. sash.reaches.the.end.position..immediately Note:.not.required.for.version.with.optional.terminal.board.for.light.curtain..On.the.version.with.light.curtain,.the. lift.&.slide.sash.is.always.opened.as.far.as.the.end.position. 44/64 12.2021 H47.MOTS0007EN...
  • Page 45: Commissioning.-.Scheme.c

    DRIVE axxent HSA smart DRIVE Commissioning.–.scheme.C PORTAL HS 11 Commissioning.–.scheme.C 11.1 General.notes.for.commissioning • Following.installation.of.the.DRIVE axxent HSA smart.(initial.commissioning),.you.must.carry.out.a.reference. run.as.well.as.a.calibration.and.teach-in.run. • The.reference.run,.as.well.as.the.calibration.and.teach-in.run.help.to.determine.the.size.of.the.lift.and.slide. element and the displacement force. • The.reference.run.must.be.performed.again.in.the.event.of.a.power.failure..The.calibration.and.teach-in.run. only.has.to.be.performed.when.commissioning.the.equipment.. • Any.tasks.relating.to.commissioning.may.only.be.completed.by.qualified.professionals. 11.2 Reference.run With.scheme.C,.a.distinction.is.made.between.the.primary.sash. .(initial.opening.sash).and.the.secondary.sash. (locking.bolt.or.hook.bolt.on.locking.side).. 1. Press.both.reset.buttons.(a).or.break.the.electric.circuit.and.then.reconnect.the.power.supply.(b) 2. Move.both.lift.&.slide.sashes.into.“Close”.position.(manually.if.necessary) 3. Press.button.on.the.lift.drive.of.the.secondary.sash. .(c) 4.
  • Page 46: Calibration.and.teach-In.run

    DRIVE axxent HSA smart DRIVE Commissioning.–.scheme.C PORTAL HS 11.3 Calibraton.and.teach-in.run Risk.of.injury!.Hands,.arms,.legs.and.feet.can.get.trapped.and/or.crushed!.There.is.no. safety.cut-off.functon! • During.the.calibration.and.teach-in.run,.maintain.a.safe.distance.from.the.moving.elements. Risk.due.to.incorrect.measured.values! • To.prevent.incorrect.measured.values,.never.interrupt.or.interfere.with.the.calibration.and.teach-in.run.of. the DRIVE axxent HSA smart.system! 1. Move.lift.&.slide.sash.into.“Close”.position.(manually.if.necessary) 2. Press.the.“PROG”.button.(a) Note:.the.LED.flashes.green.(b). 3. Press.the.button.on.the.lift.drive.of.the.secondary.sash. .for.11.seconds.(c) Note:.while.the.button.is.pressed,.the.following.tones.sound.in.succession: 1.short.alarm.signal,.2.short.alarm.signals,.3.short.alarm.signals,.4.short.alarm.signals..Then.release.the.button. 4. Press.the.button.on.the.lift.drive.of.the.secondary.sash. .for.2.seconds.(d) Note:.while.the.button.is.pressed,.1.short.alarm.signal.is.sounded..Then.release.the.button. 11 sec. 2 sec.
  • Page 47: Positions.of.the.calibration.and.teach-In.run

    DRIVE axxent HSA smart DRIVE Commissioning.–.scheme.C PORTAL HS 11.3.1 .Positons.of.the.calibraton.and.teach-in.run The.descriptions.of.the.operating.sequences.on.the.following.pages.are.based.on.the.example.of.a.primary.sash.. The.following.positions.are.approached.after.starting: 1. both.lift.&.slide.sashes. release and the primary sash .opens.slightly.(moves.to.the.waiting.position). 2. The secondary sash .opens.as.far.as.the.end.position.stop.then.moves.back.to.the.“Close”.position. 3. The secondary sash .opens.again.as.far.as.the.end.position.stop,.moves.back.to.the.“Close”.position.and. locks. 4. The primary sash .opens.as.far.as.the.end.position.stop.again,.moves.back.to.the.waiting.position,.stops. briefly.and.then.moves.on.as.far.as.the.“Close”.position. 5. The primary sash .opens.as.far.as.the.end.position.stop.again,.moves.back.to.the.waiting.position,.stops.
  • Page 48: Teaching.in.the.intermediate.stop

    DRIVE axxent HSA smart DRIVE Teaching.in.the.intermediate.stop.–.scheme.C PORTAL HS 12 Teaching.in.the.intermediate.stop.–.scheme.C • Primary sash and secondary sash .must.be.taught.in.individually.for.the.required.intermediate.stop. • Usually,.it.is.sufficient.to.teach.in.the.intermediate.stop.for.the.primary.sash.only. 12.1 Teaching.in.the.primary.sash Press.„PROG“. LED.flashes. green button Press and hold down ..3.x.short.alarm.signal,. 1.x.brief.acoustic.signal 2.x.brief.acoustic.signal primary.sash.button8.seconds... then.release.the.button..Press.and.release.the.primary.sash.button.once ..Primary.sash.stops.and.position.is.saved ..Primary.sash.unlocks.and.starts.to.move... Press.position.1x.briefly... 12.2 Teaching.in.the.secondary.sash Press.„PROG“.
  • Page 49: Operation.-.Scheme.c

    DRIVE axxent HSA smart DRIVE Operaton.–.scheme.C PORTAL HS 13 Operaton.–.scheme.C Scheme.C.lift.and.slide.elements.have.two.controllable.lift.&.slide.sashes.(primary.sash. and secondary sash )..The.primary.sash.is.the.initial.opening.sash.and.the.secondary.sash.opens.next..The.primary.sash.and.secondary. sash.positions.(right.or.left.lift.&.slide.sash).must.be.specified.when.placing.your.order..In.the.examples.in.these. instructions,.the.left-hand.lift.&.slide.sash.is.the.primary.sash.and.the.right-hand.lift.&.slide.sash.is.the.secondary. sash. Note:.the.button.for.the.primary.sash.controls.the.corresponding.lift.&.slide.sash.individually. The.button.for.the.secondary.sash.controls.both.lift.&.slide.sashes.at.the.same.time. 13.1 “Open”.-.“Stop”.-.“Lock”.operaton Every.time.the.button.is.pressed,.the.function.switches.between.“Open”.-.“Stop”.-.“Lock”. Note:.the LED lights up green when opening. The LED lights up red when closing and locking Primary.sash.button.
  • Page 50: Intermediate.stop.(Limited.opening.width)

    DRIVE axxent HSA smart DRIVE Operaton.–.scheme.C PORTAL HS 13.3 Intermediate.stop.(limited.opening.width) The.primary.and.secondary.sashes.are.controlled.individually.and.then.move.to.the.taught.in.intermediate.stop. Primary.sash.button. (primary.sash.is.controlled) Press and hold down the.button.for.2.seconds... Primary sash in “intermediate stop” Primary sash opens ... 1.x.brief.acoustic.signal Secondary.sash.button. (primary.sash.and.secondary.sash.are.controlled) Press and hold down the.button.for.2.seconds... Primary.sash.moves.into.waiting.position Secondary sash opens ...
  • Page 51 DRIVE axxent HSA smart DRIVE Operaton.–.scheme.C PORTAL HS 13.4 Special.functon.“Opening.as.far.as.the.end.positon”.(stop) For.safety.reasons,.both.lift.&.slide.sashes.do.not.open.fully.in.normal.motor-powered.operation..To.open.the.lift. &.slide.sashes.fully.(i.e..to.move.them.to.their.absolute.end.position.(as.far.as.the.stop)),.they.can.be.manually. pushed.open.individually.or.moved.to.the.end.position.by.pressing.the.button.on.the.corresponding.lift.drive.HA.. The.lift.&.slide.sashes.must.be.in.the.“OPEN”.position.before.they.can.be.moved.to.their.absolute.end.position. Secondary.sash.button. (primary.sash.and.secondary.sash.are.controlled) Press.1x.briefly ..both.lift.&.slide.sashes.open..Press and hold down the.button..Lift.&.slide.sash.opens.further... Operate primary and secondary sashes individually ..release.the.button.when.the.lift.&. slide.sash.reaches.the.end.position..Lift.&.slide.sash.stops.immediately Note:.this.special.function.can.only.be.executed.for.the.primary.and.secondary.sashes.separately. Note:.not.required.for.version.with.optional.terminal.board.for.light.curtain..On.the.version.with.light.curtain,.the. lift.&.slide.sash.is.always.opened.as.far.as.the.end.position. H47.MOTS0007EN 12.2021 51/64...
  • Page 52: Manual Emergency Operation

    DRIVE axxent HSA smart DRIVE Manual.emergency.operaton PORTAL HS 14 Manual.emergency.operaton If.the.lift.drive.HA.fails,.the.lift.&.slide.sash.can.be.lifted/lowered.manually.with.the.emergency.operating.key.that. is.included.in.the.scope.of.delivery..Once.it.has.been.lifted/lowered,.the.lift.&.slide.sash.can.be.moved.manually.. The.manual.sliding.speed.must.not.exceed.150.mm/second,.otherwise,.this.could.result.in.malfunctions Note:.the.emergency.operating.key.is.designed.solely.for.manual.operation.in.the.event.of.a.malfunction..It. should.therefore.be.kept.in.the.vicinity.of.the.lift.and.slide.element. Injury.hazard.due.to.emergency.operatng.key.snapping.back! • During.manual.operation.with.the.emergency.operating.key,.hold.it.sufficiently.firmly..When.the.unit.is. unlocked,.the.emergency.operating.key.takes.the.weight.of.the.lift.&.slide.sash. Emergency.operating.key 52/64 12.2021 H47.MOTS0007EN...
  • Page 53: Retrofit Of Radio Remote Control

    DRIVE axxent HSA smart DRIVE Retrofit.of.radio.remote.control PORTAL HS 15 Retrofit.of.radio.remote.control The.radio.receiver.and.the.radio.remote.control.must.be.purchased.separately..They.are.not.produced.by.SIEGE- NIA. The.producer.of.the.radio.receiver.and.the.radio.remote.control.is.the.the.company.Erone.CDVI.WIRELESS.SPA,.Via. Piave.No..23,.I-31020.San.Pietro.di.Feletto.-.Treviso. www.erone.com 15.1 Original.assembly.and.operatng.instructons You.can.find.the.original.assembly.and.operating.instructions.for.the.radio.receiver.and.the.radio.remote.control. here: original.instructions.for.the.radio.receiver original.instructions.for.the.radio.remote.control 15.2 EU.Declaratons.of.conformity You.can.find.the.declaration.of.conformity.for.the.radio.receiver.and.the.radio.remote.control.here: declaration.of.conformity.for.the.radio.receiver declaration.of.conformity.for.the.radio.remote.control H47.MOTS0007EN 12.2021 53/64...
  • Page 54: Installation.of.radio.receiver

    DRIVE axxent HSA smart DRIVE Retrofit.of.radio.remote.control PORTAL HS 15.3 Installaton.of.radio.receiver 15.3.1 .Removal.of.cover.for.slide.drive 15.3.2 .Installaton.of.radio.receiver. The.radio.receiver.is.fixed.on.the.cover.supportng. piece.behind.the.deflecton.roller. 3.5x13 54/64 12.2021 H47.MOTS0007EN...
  • Page 55: Electrical.connection.for.radio.receiver

    DRIVE axxent HSA smart DRIVE Retrofit.of.radio.remote.control PORTAL HS 15.3.3 .Electrical.connecton.for.radio.receiver + = red = to pos. 8 -.=.black.=.to.pos..7 C.=.green.=.to.pos..5 NA.=.yellow.=.to.pos..6 15.3.4 .Technical.specificatons.of.the.radio.receiver Receiver.type Superhet.(heterodyne.receiver) Carrier.frequency 433.92 MHz AM/ASK Demodulation Intermediate.frequency 10.7 MHz Input.sensitivity -103.dBm Interference.frequency <.-57.dBm Input resistance 50.Ω Mains.voltage 12.-.24.V...
  • Page 56: Operation.with.the.radio.remote.control

    DRIVE axxent HSA smart DRIVE Retrofit.of.radio.remote.control PORTAL HS 15.4 Operaton.with.the.radio.remote.control ATTENTION Blue LED The.remote.control.in.taught-in.in.the.factory. Operating.button The.following.steps.for.the.teach-in.of.the.remote. Battery.tray control.only.refer.to.a.change.in.the.adjustments.or. to.the.teach-in.of.a.further.remote.control. front rear • Teach-in.steps.for.the.first.remote.control.are. ≥1.sec. 1.sec. not necessary • BOTH.sashes.are.always.moved.synchronously.in. Key.tab the.„scheme.C“.version 15.4.1 .Seat.of.the.radio.receiver RH.stop.is.demonstrated..The.steps.are.laterally.reversed.for.LH.stop. The.programming.button.of.the.radio.receiver.is.accessible.through.an. opening.on.the.bottom.side.of.the.cover 15.4.2 .Teach-in.remote.control 5.sec. hold...
  • Page 57: Deleting.individual.windows.from.remote.control

    DRIVE axxent HSA smart DRIVE Retrofit.of.radio.remote.control PORTAL HS 15.4.3 .Deletng.individual.windows.from.remote.control hold hold 15.4.4 .Deletng.complete.memory e..g..if.the.remote.control.is.lost hold hold The.remaining.remote.control/S.must.be.taught-in.again 15.4.5 .Battery.replacement.and.technical.specificatons.of.radio.remote.control Technical.data.of.the.radio.remote.control Number.of.functions Supply.voltage 2.piece.Lithium.battery.CR2016 12.-.18.months.(depending.on.user) Ø.Service.life.of.the.batteries 2x CR2016 Power.consumption 15 mA Radio.frequency 433.92 MHz Number.of.code.combinations Modulation AM/ASK Rated power E.R.P.
  • Page 58: Maintenance

    16 Maintenance Electrically.operated.unit. Risk.of.fatal.injury.from.electric.shock.or.fire. To.prevent.personal.injury.or.damage.to.property,.always.comply.with.the.following.instructons: • pull.the.mains.plug.out.of.the.socket.prior.to.every.cleaning.process.or.maintenance.work..Never.pull.at.the. cable.to.disconnect.the.device.from.the.electricity.grid. • for.all.devices.with.a.fixed.connection.to.the.230.V.AC.mains.power.supply,.switch.off.all.poles.of.the.feeder.. The.safety.devices.must.be.removed.if.necessary. 16.1 Cleaning Important:.when cleaning the DRIVE axxent HSA smart,.do.not.allow.any.liquids.to.get.inside.the.device. • Never.use.cleaning.agents.that.are.aggressive.or.contain.solvents,.or.sharp-edged.objects,.as.these.may.damage. the surfaces of the casing. • Never.clean.the.unit.with.a.high-pressure.cleaner.or.steam-jet.cleaner. • Clean the DRIVE axxent HSA smart.with.a.cloth.moistened.with.a.mild.soap.solution.or.cleaning.agent. • Comply.with.the.safety.regulations.for.operating.electrical.equipment.and,.if.necessary,.for.ladders,.steps.and. work.overhead.or.at.certain.heights. 58/64 12.2021...
  • Page 59 DRIVE axxent HSA smart DRIVE Rectficaton.of.malfunctons PORTAL HS 17 Rectficaton.of.malfunctons In.case.of.a.malfunction,.do.not.open.the.unit.or.try.to.repair.it.under.any.circumstances.. If.the.problem.is.not.listed.in.the.table.below,.please.contact.your.window.specialist.or.SIEGENIA.directly:.Tel..+49. 271.3931-0 17.1 Faults./.causes./.descripton.of.soluton.DRIVE axxent HSA smart Descripton.of.fault Possible.cause Proposed.soluton No power supply Check power supply Infrared remote control not See.operating.instructions.–. taught in infrared remote control DRIVE axxent HSA smart not Perform reference run flashes.red...
  • Page 60: Technical.specificatons

    DRIVE axxent HSA smart DRIVE Technical.specificatons PORTAL HS 17.2 SI Comfort app You.will.find.detailed.operating.information.and.information.on.how.to.rectify.malfunctions.on.the.SIEGENIA Smarthome Internet page. https//smarthome.siegenia.com 18 Technical.specificatons Specificatons.for.DRIVE axxent HSA smart Supply.voltage 120.-.230.V,.22.W Operating.voltage.for.device 24 V (power.supply.integrated.in.slide.drive) Max..displacement.force.during.slide.operation approx. 60 N Max..torque.of.the.emergency.operating.key approx. 2 Nm Traverse.speed approx. 150 mm/sec.
  • Page 61 DRIVE axxent HSA smart DRIVE .Accessories PORTAL HS 19 .Accessories Jig.catch GABB0010-0E501_ Jig.through.hole GABB0020-0E501_ Jig.lift.drive.HA PAFB0020-00001_ Radio.receiver GZFB0040-00001_ Smart.module.retrofit.set GZFM1100-00001_ Radio.remote.control GZFB0050-00001_ Available.from.company. CEDES.GmbH Light.curtain.(inside/outside) Elzmatten.6. D-79365.Reinhausen H47.MOTS0007EN 12.2021 61/64...
  • Page 62 DRIVE axxent HSA smart DRIVE EC.declaraton.of.incorporaton PORTAL HS 20 EC.declaraton.of.incorporaton Producer SIEGENIA-AUBI.KG Hardware.and.ventilation. technology Duisburger Straße 8 57234 Wilnsdorf HS.drive declares.that.the.product: device.type: DRIVE axxent HSA smart type.designation meets.the.following.fundamental.requirements: EC.Machinery.Directive 2006/42/EC EMC.Directive 2014/30/EU EN.301.489-1 EN.301.489-17 Low.voltage.directive 2014/35/EU EN.60335-1:2012 EN.60335-2-103:2010 RoHS.Directive 2011/65/EU This.declaration.is.based.on.test.reports.from:...
  • Page 64 www.siegenia.com...

Table of Contents