Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
W&H Med Manuals
Dental equipment
RIS-311
Instructions for use manual
W&H Med Lara XL Instructions For Use Manual
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
page
of
110
Go
/
110
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Conformity
Symbols and Messages
Safety Symbols Used in this Manual
Property Damage Messages
Introduction
About this Manual
Manual Content
Copyright Notice
Use Restrictions
Intended Use
User Qualification
Safety Information
Safety Warnings
Responsibility
User Responsibility
Manufacturer Responsibility
Getting Started
Unpacking
Contents of the Packaging
Handling
Product Description
Front View
Rear View
Installing the Sterilizer
Location Requirements
Electrical Connections
Water Connections
Filling the Clean Water Tank
Lan Connection
Operating the Sterilizer
Homepage Description
User Interface Menu
Main Menu Functions
Maintenance Menu Functions
Sterilizer Setup
Guided Configuration
Connect to a Network
User Authentication
Pin Management
Change Your Pin
Elitrace (Optional)
USB Pen Drive
Standby Mode
Administrator
User Management
Add a User
Delete a User
Traceability Options
Hide/Unhide a Cycle
Managing Printers
Printer Selection (Optional)
Label Printer Selection (Optional)
Label Printer Usage (Optional)
Label Content Description
Sterilizer Tests
Sterilizer Performance Tests
Bowie and Dick Test
Purpose of the Test
Helix Test
What to Do Next
Vacuum Test
Sterilization Cycles
Load Maintenance and Preparation
Prepare the Sterilizer
General Recommendations
Sterilization Cycle Description
Sterilization Cycle Management
Unloading
Sterilization Cycle Report
Maintenance
Warnings for Maintenance Operations
Ordinary Maintenance
Monthly or 50-Cycle Maintenance
400-Cycle Maintenance
800-Cycle or Biannual Maintenance
Clean the Water Tank
800-Cycle Maintenance
Replacing the Door Gasket
4000 Cycle or Five-Year Maintenance
Extraordinary Maintenance
Disposal
Diagnostics
Errors
Messages and Alerts
Troubleshooting
Reset the Safety Thermostat
Troubleshooting Table
Emergency Door Opening
Technical Data
Sterilization Cycles
Sterilization Cycle Phases
Technical Data
Installation Requirements
Recommendations for Validation
Diagrams
Connection Diagrams
Water Quality
Accessories, Spare Parts, Consumables
List of Accessories and Spare Parts
Activation Codes
Authorized W&H Service Partners
Documentation Forms
W&H Installation Check-List
Installation Information
Advertisement
Quick Links
Download this manual
Instructions for Use
RIS-311
RIS-311 Med - ENG - Rev02
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Troubleshooting
Troubleshooting
83
TROUBLESHOOTING TABLE
85
Need help?
Do you have a question about the Lara XL and is the answer not in the manual?
Ask a question
Questions and answers
Subscribe to Our Youtube Channel
Related Manuals for W&H Med Lara XL
Laboratory Equipment W&H Med Lexa Plus Instructions For Use Manual
(106 pages)
Summary of Contents for W&H Med Lara XL
Page 1
Instructions for Use RIS-311 RIS-311 Med - ENG - Rev02...
Page 3: Table Of Contents
USB pen drive Maintenance Standby mode Warnings for maintenance operations Administrator Ordinary maintenance User management Monthly or 50-cycle maintenance Traceability options 400-cycle maintenance Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 4
Sterilization cycle phases Technical data Recommendations for validation Diagrams Water quality Accessories, spare parts, consumables Authorized W&H service partners Documentation forms W&H installation check-list Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 5: Conformity
Waste Electrical and Electronic Equipment Directive (WEEE). Small steam sterilizers. EN 13060 IEC 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use, general requirements. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 6: Symbols And Messages
PROPERTY DAMAGE MESSAGES Notice: Indicates information considered important, but not hazard-related. Typically to avoid damage to the product. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 7
Manufacturing date (YYYY- MM-DD). The sterilizer must be transported authorized technicians due Country of manufacture. to its heavy weight. ON (supply) IEC 60417- 5007. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 8: Introduction
Even partial duplication of drawings, decommissioning. For this reason, it should always be accessible to images or text is prohibited. operators both online and offline. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 9: Use Restrictions
The devices are intended for professional use by trained people only. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 10: Safety Information
(see "Run a sterilization cycle" on page 53). Do not drink any water that has been inside the sterilizer. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 11: Responsibility
It is recommended not to leave the machine unattended. Note: a list of security information is mentioned in the MDS2 document, which is available on request. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 12: Getting Started
Weight: 60.7 kg (133.8 lbs) Operating the sterilizer User interface menu Sterilizer setup User authentication EliTrace (optional) USB pen drive Standby mode Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 13: Contents Of The Packaging
Note: The packaging of the product is environmentally friendly and can be disposed of by industrial recycling companies. Sterilizer Trays (four + two) Chamber rack Tray holder Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 14
LAN cable for connecting the sterilizer to a network (optional) Emergency door opening tool Tube for drain connection See "Accessories, spare parts, consumables" for a full list of optional accessories. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 15: Handling
Allow the sterilization chamber to cool down Use original packaging when shipping or transporting the sterilizer. Replacement packaging materials are available from Service W&H Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 16: Product Description
Service door Sterilization chamber Safety thermostat reset Bacteriological filter Door gasket Clean tank cover-cap Clean water tank Tank internal filter with metal cartridges Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 17
Identification label Used water drain connection (grey) Clean water drain connection (blue) Drain tube release buttons Port for emergency door opening tool Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 18: Rear View
LAN port USB ports Pressure safety valve cover Used water drain Water supply inlet Condenser grid Power cord guides Power cord socket Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 19
Getting started CHAMBER ACCESSORIES Part Description Tray Chamber rack. It can host trays or cassettes inserted horizontally or vertically. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 20: Installing The Sterilizer
The installation of the sterilizer shall be performed by two authorized technicians using PPE (Personal Protective Equipment) according to applicable standards. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 21: Water Connections
: the clean water tank and the used water tank. sounds; stop filling. For this reason is necessary to periodically fill the clean water tank and draining the used water tank. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 22
Use left connector (blue, 1) for the clean water and the right connector (grey, 2) for the used water. Let the water flow from the tank completely. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 23: Lan Connection
Insert the Wi-Fi dongle key in the USB port. Read the Instructions for Use provided with the Wi-Fi dongle key. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 24: Operating The Sterilizer
Note: at the first start-up of the sterilizer, the Guided Configuration procedure automatically appears; see "Sterilizer setup" on page 31 . The homepage appears with the enabled sterilization cycles. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 25: User Interface Menu
Ethernet Manages the Ethernet network. Accessories Opens the pages to accessories management. Maintenance Carries out the maintenance procedure. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 26
Prints a test label. Test Chooses if the sterilizer is master or slave. Traceability Settings Special Codes Allows to enter a special code. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 27: Maintenance Menu Functions
Accesses and checks the water conductivity. Protects with a password the cycle start, the cycle stop and the load release. Service Opens the Service menu. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 28
Getting started Icon Label Function Software Update Installs and upload the software. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 29
Copy the error log/reports to the changed and appears by clicking on USB pen drive. Confirms the active option and saves a setting or a parameter. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 30
Increases/decreases the value. Indicates that the option is active/not active. Indicates that the option is enabled/disabled. Show an animation about the replacement procedure. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 31: Sterilizer Setup
To change the display brightness: On the homepage, tap > > to change the value. to confirm. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 32: Connect To A Network
Configuration and in the DNS Configuration fields. Tap on each entry field and enter the IP addresses (ask your IT manager for details). Then tap to confirm. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 33: Elitrace (Optional)
If the sterilizer is not Note: for more information see the dedicated documentation. used for a certain period of time, it automatically switches to Standby mode. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 34
CHANGING STANDBY MODE DELAY TIME On the homepage, tap > > to change the delay time. to confirm. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 35: Administrator
Tap the user name you want to delete. Enter the PIN and tap to confirm. to confirm. Tap the text box: a keyboard appears. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 36: Traceability Options
Only a user with administrator rights can hide a cycle or make it Only a user with administrator rights can set the traceability options. available to users on the homepage. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 37
to unhide a cycle from the homepage. to confirm and go back to the previous page. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 38: Managing Printers
> > > Tap the model of the printer to use. to confirm and go back to the previous page. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 39: Label Printer Usage (Optional)
The automatic printing option permits to automatically print a preset complete. number of labels after a successful sterilization cycle. The labels are Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 40
On the homepage, tap > > > Activate Manual printing. to confirm and go back to the previous page. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 41: Label Content Description
Date and time of cycle start Expiry date of the bag/package. Expiry The cycle outcome if a storage time is not set. date Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 42: Sterilizer Tests
tightness of the pneumatic circuit Bowie and Dick test CAUTION! Follow local/national guidelines on the frequency of testing. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 43: Purpose Of The Test
Place the Bowie and Dick test pack in the center of a tray in the lowest rack position and close the chamber door. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 44
Remove the indicator sheet from the center of the test pack and check the change in colour. See "Interpret the test result" on the next page Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 45
Certain areas of the indicator sheet have not changed colour since there was an Repeat the test. If it fails air pocket during the cycle due to sterilizer malfunction. repeatedly, call technical service. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 46: Helix Test
Unscrew the tube capsule and place inside it an indicator strip according to the instructions of the test manufacturer. Screw the capsule. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 47
Unscrew the tube capsule and remove the indicator strip. Check the change in colour. See "Interpret the test result" on the next page Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 48: What To Do Next
It consists of a vacuum phase, followed by a stabilization period of 5 minutes and a testing period of 10 minutes. The internal pressure is monitored during the testing period. The pressure rise must be less than 0.013 bar (0.19 psi). Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 49
Clean the chamber face side and the chamber filters. Repeat the Vacuum test. See "Carry out the test" above. If the test fails repeatedly, call technical service. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 50: Sterilization Cycles
Risk of burns. Before touching, ensure the sterilization sterilizer. The manufacturer’s warranty is void in case of damage chamber is cold. caused by chemicals. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 51
Ensure that packs do not touch the walls of the chamber. Place sterilization pouched items with the paper side facing up. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 52: Prepare The Sterilizer
Insert cassettes horizontally or vertically, or insert trays. See "Load maintenance and preparation" on page 50 for load requirements and "Chamber accessories" on page 19. Close the door. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 53: Sterilization Cycle Management
25% of additional drying duration. ECO DRY The drying time is adjusted to the total amount of load with +50% a 50% of additional drying duration. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 54
See "View the cycle parameters" on page 56. Tap OPEN: the door unlocks and the homepage appears. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 55
Maximum two cycles can be programmed. to confirm and go back to the previous page. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 56
Current cycle phase Stop button to go back to the homepage. Button to open the cycle information page Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 57
Reprocess the load if necessary. Remove the load and stock it. CAUTION! Hot steam. Wait the steam to dissipate before opening the door. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 58: Unloading
LAN . to print the report, or tap to save the report on the USB pen drive. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 59
To check if the parameters entered are valid, see "Test the data stored in the USB. storage " on the next page. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 60
On the homepage, tap > > > to start the remote saving. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 61
MIN, MAX temperature MIN, MAX pressure Plateau/Sterilization phase end Drying phase start Drying phase end Pressure leveling phase Cycle end conditions Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 62
Description Cycle time Cycle time Date (below) Cycle end date and time "Cycle completed" Cycle outcome Trk. Tracking code for traceability management Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 63: Maintenance
Notice: Follow the instructions in this chapter when carrying out any maintenance on the sterilizer. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 64: Ordinary Maintenance
: even if the maximum cycle number is not reached, it is recommended to replace the consumable parts every year, or if they appear worn or damaged, or if the filters are clogged or discolored. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 65
When you have replaced the consumable tap to confirm: the executed cycle counter is reset. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 66: Monthly Or 50-Cycle Maintenance
Rinse with clean water. Note: when the seal is new it might be necessary to hold the door gently closed at the sterilization start. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 67
Reposition all pieces of the chamber accessories properly. Note: The trays and the tray holder may also be cleaned in a washer disinfector. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 68
Notice: never use any other disinfectant, detergent or abrasive product, as they might result aggressive for the external covers and damage them. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 69: 400-Cycle Maintenance
Open the service door. Unscrew the bacteriological filter by hand (counter-clockwise). Screw on the new bacteriological filter (clockwise) and tighten it snug. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 70: 800-Cycle Or Biannual Maintenance
To drain the detergent solution during the subsequent cleaning, leave the drain tube attached to the drain connection of the tank you want to clean. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 71
Maintenance ACCESS TO THE WATER TANK Proceed as follows: Lift the water tank cover. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 72: Clean The Water Tank
Clean the metal cartridge of the internal filter with tap water. Reposition the internal filter. Detach the drain tube. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 73: 800-Cycle Maintenance
Carefully clean the seal seat and the chamber face side with a damp, lint-free cloth. Moisten the new seal with water to facilitate its placement. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 74
Wipe any residual water and run a Vacuum and Helix test to check for perfect tightness of the seal. See "Vacuum test" on page 48 and "Helix test" on page 46. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 75: 4000 Cycle Or Five-Year Maintenance
For each element, the actions to carried out are the following: Element Replace Clean Check Electro valves Vacuum pump internal parts Sterilization chamber and external surfaces Chamber filters Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 76: Extraordinary Maintenance
When the water has been completely drained, press the release button to remove the drain tube and close the service door. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 77: Disposal
The same instructions apply to disposal of all used consumable parts. MATERIALS The sterilizer is mainly built from fiber-reinforced polymers, metals and electric / electronic components. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 78: Diagnostics
Check the dust filter and ensure that the sterilizer fan is not blocked. See error "13x to 16x" on the next page. Repeat the cycle. If the problem persists, call service. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 79
If the problem persists, call service. Wait for the chamber to cool down. Reset the safety thermostat (see "Extraordinary maintenance" on page 76). Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 80
Check if the door can move freely without touching the trays or the load when closing. Switch the sterilizer OFF and ON. The cycle has been aborted by the user. Re-process the load. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 81: Messages And Alerts
... cycles. is to be scheduled. Have you already booked the 4000 cycle service? Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 82
- Door gasket If the problem persists, contact your Technical Service. - Dust filter If the problem persists contact the service. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 83: Troubleshooting
During the sterilization cycle, the sterilizer is continuously monitored by a control system. If an anomaly is detected, the cycle is aborted automatically, and the sterilizer starts a reset phase. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 84: Reset The Safety Thermostat
Note: If the thermostat operates repeatedly, call technical service. Wait for the sterilizer to finish the error reset phase and follow the instructions on the display. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 85: Troubleshooting Table
One or more chamber filter caps not well-positioned. Mount the chamber filter caps properly (see "Ordinary maintenance" on page 64). Load incorrectly placed. See "Load maintenance and preparation" on page 50 Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 86
Remove any objects interfering with the chamber door. Check the door does not force message appears. itself. against the load or the chamber furniture. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 87
Call service to order the requested component (door gasket, dust filter, bacteriological maintenance. maintenance of the sterilizer. filter…). See "Ordinary maintenance" on page 64 Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 88: Emergency Door Opening
The door locking system is electrically activated. In case the door remains locked due to a black-out or an electric fault, an auxiliary unlocking procedure is available. OPEN THE DOOR IN EMERGENCY Unplug the sterilizer and wait at least three hours. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 89
Extract the opening tool placed behind the service door. Remove the cap. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 90
Insert the opening tool into the hole and then turn it counterclockwise until the door is unlocked (proceed slowly until it stops). Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 91: Technical Data
Processing bagged items with the S Naked cycle will result in wet bags/pouches at the end of the cycle, exposing the items to contamination due to improper storage. The display reminds the maximum permitted load before starting a cycle. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 92
The instruments sterilized with this cycle cannot be stored: they must be used immediately after being sterilized. *: cycle name might be different, depending on country requirements. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 93
: the liquids are excluded. : "medical load" is intended as a load up to steam penetration grade 7 according to EN ISO 17665-3. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 94
B Prion / Extended 134 B Universal 121 S Naked 134 30'30'' 49'30'' Note: values and cycle names could be different depending on country requirements. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 95
9.0 kg (19.8 lbs) B Prion / Extended 134 9.0 kg (19.8 lbs) B Universal 121 9.0 kg (19.8 lbs) S Naked 134 not suitable Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 96: Sterilization Cycle Phases
Short phase to clean the circuit from used water. Leveling. Pressure inside the sterilization chamber is leveled to the atmospheric pressure. End of the cycle. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 97
All type B sterilization cycles feature the same basic pressure profile as shown in the graph below. The duration and the temperature of the sterilization phase differ between the various cycles. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 98
The S Fast 134 cycle is specifically designed to sterilize unwrapped instruments, for immediate use on patients, not requiring a complete drying. Thus, the drying phase of this cycle is short, making this cycle the fastest available. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 99: Technical Data
Max. RH 80% up to 31 °C (88 °F), linearly decreasing to 50% at 40 °C (104 °F) STEAM GENERATOR Pressure safety valve 5 bar (72.51 psi) Safety thermostats 230 °C (446 °F) Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 100: Recommendations For Validation
*: usable space with standard rack and trays. With optional racks and trays, Hottest points see Accessories, spare parts, consumables. : the unit of measurement used is U.S. liquid gallons. Coldest points Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 101: Diagrams
(*): The water filtration system must be fitted with a backflow preventing device complying to IEC 61770 and to national and local regulations. For water requirements see "Technical data" on page 99. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 102: Water Quality
< 2 mg/l Phosphate < 0.5 mg/l Conductivity (at 20°C) < 15 µS/cm pH value 5–7 Appearance colorless, clean, free from sediment Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 103: Accessories, Spare Parts, Consumables
Aluminium tray (22 l) USB pen drive V000004X 19721108 Serial printer Large aluminium tray F523211X A801503X USB adapter for serial printer Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 104: Activation Codes
Osmo water demineralizer (220 V) ACTIVATION CODES Activation code Description Part number 19721136 Wi-Fi dongle key EliTrace Activates the EliTrace function. 19730059 Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 105: Authorized W&H Service Partners
Technical data Authorized W&H service partners A list and a map with your nearest W&H service partner are available at med.wh.com. Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 106: Documentation Forms
Have you removed all the protection covers from the Have you shown the Head of the clinic/practice what the sterilizer and from all the ship-with? messages and alarms mean? Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 107: Installation Information
Have you shown and explained to the head of the clinic/practice the safety advise section? Check Have you executed a Vacuum test? Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 108
Send a copy of the installation check-list duly filled-in to both of the following addresses: +43 6274 6236-55 Fax: Ignaz-Glaser-Straße 53, Postfach 1 Mail 5111 Bürmoos Austria Lara XL | Instructions for Use | RIS-311 Med ENG Rev02 | 01/06/2022 | © W&H Sterilization Srl...
Page 110
RIS-311 Med W&H Sterilization Srl Instructions for Use via Bolgara, 2 Brusaporto (BG) Rev02 Italy 01/06/2022 +39 035 66 63 000 Subject to changes ...
This manual is also suitable for:
Ris-311
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the Lara XL and is the answer not in the manual?
Questions and answers