AVTECH ELECTROSYSTEMS AVO-5C-C Instructions Manual

Pulsed laser diode driver

Advertisement

Quick Links

P.O. BOX 265
OGDENSBURG, NY
U.S.A. 13669-0265
A V T E C H
TEL: 888-670-8729 (USA & Canada) or +1-613-226-5772 (Intl)
FAX: 800-561-1970 (USA & Canada) or +1-613-226-2802 (Intl)
info@avtechpulse.com
INSTRUCTIONS
MODEL AVO-5C-C
0 TO 8 AMPS, 5 MHz
5 – 50 ns PULSE WIDTH
PULSED LASER DIODE DRIVER
SERIAL NUMBER: ____________
E L E C T R O S Y S T E M S
N A N O S E C O N D
W A V E F O R M
S I N C E
-
http://www.avtechpulse.com/
E L E C T R O N I C S
1 9 7 5
BOX 5120, LCD MERIVALE
X
OTTAWA, ONTARIO
CANADA
L T D .
K2C 3H4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AVO-5C-C and is the answer not in the manual?

Questions and answers

Summary of Contents for AVTECH ELECTROSYSTEMS AVO-5C-C

  • Page 1 OGDENSBURG, NY FAX: 800-561-1970 (USA & Canada) or +1-613-226-2802 (Intl) OTTAWA, ONTARIO U.S.A. 13669-0265 CANADA K2C 3H4 info@avtechpulse.com http://www.avtechpulse.com/ INSTRUCTIONS MODEL AVO-5C-C 0 TO 8 AMPS, 5 MHz 5 – 50 ns PULSE WIDTH PULSED LASER DIODE DRIVER SERIAL NUMBER: ____________...
  • Page 2: Warranty

    WARRANTY Avtech Electrosystems Ltd. warrants products of its manufacture to be free from defects in material and workmanship under conditions of normal use. If, within one year after delivery to the original owner, and after prepaid return by the original owner, this Avtech product is found to be defective, Avtech shall at its option repair or replace said defective item.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS WARRANTY........................2 TECHNICAL SUPPORT....................2 TABLE OF CONTENTS....................3 INTRODUCTION.......................5 AVAILABLE OPTIONS......................5 SPECIFICATIONS......................7 EUROPEAN REGULATORY NOTES................8 EC DECLARATION OF CONFORMITY.................. 8 DIRECTIVE 2002/95/EC (RoHS)..................... 8 DIRECTIVE 2002/96/EC (WEEE).................... 8 INSTALLATION......................10 VISUAL CHECK........................10 POWER RATINGS........................ 10 CONNECTION TO THE POWER SUPPLY................10 PROTECTION FROM ELECTRIC SHOCK................
  • Page 4 PCB 168B - HIGH VOLTAGE DC POWER SUPPLY............29 PCB 126B - OSCILLATOR AND TRIGGER CIRCUIT............30 MAIN WIRING........................31 PERFORMANCE CHECK SHEET.................32 Manual Reference: Z:\officefiles\instructword\avo-5c\avo-5c-c,edition_i.odt. Last modified March 29, 2007. Copyright © 2007 Avtech Electrosystems Ltd, All Rights Reserved.
  • Page 5: Introduction

    INTRODUCTION The AVO-5C-C is a high performance instrument capable of generating up to 8 Amps into low impedance loads at repetition rates up to 5 MHz. The output pulse width is variable from 5 to 50 ns, and the sync delay is variable up to 200 ns. The rise and fall times are less than 3 ns typically.
  • Page 6 -M Option: a monitor output is provided.
  • Page 7: Specifications

    SPECIFICATIONS Model: AVO-5C-C Amplitude 0 to 8 A Required load 1.5 Ω impedance: Pulse width (FWHM): 5 to 50 ns Maximum duty cycle: Rise and fall times: ≤ 3 ns (with AVO-5C-TA) (20%-80%) ≤ 6 ns (with AVO-5C-TB) PRF: 0 to 5 MHz Output impedance: ≈...
  • Page 8: European Regulatory Notes

    EUROPEAN REGULATORY NOTES EC DECLARATION OF CONFORMITY Avtech Electrosystems Ltd. P.O. Box 5120, LCD Merivale Ottawa, Ontario Canada K2C 3H4 declare that this pulse generator meets the intent of Directive 89/336/EEC for Electromagnetic Compatibility. Compliance pertains to the following specifications as...
  • Page 9 WEEE compliance (as mandated in Directive 2002/96/EC of the European Union and local laws) on behalf of the customer, as provided for under Article 9 of Directive 2002/96/EC. Customers who have purchased Avtech equipment through local representatives should consult with the representative to determine who has responsibility for WEEE compliance.
  • Page 10: Installation

    INSTALLATION VISUAL CHECK After unpacking the instrument mainframe and the transformer module, examine to ensure that they have not been damaged in shipment. Visually inspect all connectors, knobs, and handles. Confirm that a power cord and an instrumentation manual (this manual), are with the instrument.
  • Page 11: Protection From Electric Shock

    Destination Region Description Manufacturer Part Number European CEE 7/7 Continental Europe Qualtek (http://www.qualtekusa.com) 319004-T01 “Schuko” 230V, 50Hz BS 1363, United Kingdom Qualtek (http://www.qualtekusa.com) 370001-E01 230V, 50Hz SEV 1011, 2 Switzerland Volex (http://www.volex.com) 2102H-C3-10 30V, 50Hz SI 32, Israel Volex (http://www.volex.com) 2115H-C3-10 220V, 50Hz North America,...
  • Page 12 4. maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly to 50 % relative humidity at 40 °C; 5. Mains supply voltage fluctuations up to ±10 % of the nominal voltage; 6. no pollution or only dry, non-conductive pollution.
  • Page 13: Fuses

    FUSES This instrument contains four fuses. All are accessible from the rear-panel. Two protect the AC prime power input, and two protect the internal DC power supplies. The locations of the fuses on the rear panel are shown in the figure below: Fuses #1 and #2 Fuse #4 Fuse #3...
  • Page 14: Dc Fuse Replacement

    DC FUSE REPLACEMENT The DC fuses may be replaced by inserting the tip of a flat-head screwdriver into the fuse holder slot, and rotating the slot counter-clockwise. The fuse and its carrier will then pop out. FUSE RATINGS The following table lists the required fuses: Recommended Replacement Part Nominal Fuses...
  • Page 15: Front Panel Controls

    FRONT PANEL CONTROLS 1) POWER Switch . This is the main power switch. When turning the instrument on, there may be a delay of several seconds before the instrument appears to respond. 2) OVERLOAD Indicator . When the instrument is powered, this indicator is normally green, indicating normal operation.
  • Page 16 connector is an output, which supplies a 2V, 50 ns wide pulse for each trigger event. This output may be used to trigger oscilloscopes or other equipment. 5) Delay Controls . When the PRF Range Switch is set to one of the four internal oscillator ranges, the main output is advanced or delayed relative to the TRIG output pulse (item 3).
  • Page 17: Rear Panel Controls

    REAR PANEL CONTROLS SMOOTH 1. AC POWER INPUT . An IEC-320 C14 three-pronged recessed male socket is provided on the back panel for AC power connection to the instrument. One end of the detachable power cord that is supplied with the instrument plugs into this socket. 2.
  • Page 18: General Information

    GENERAL INFORMATION BASIC TEST ARRANGEMENT The AVO-5C-C should be tested with a sampling oscilloscope with a bandwidth of at least 1 GHz to properly observe the high-speed waveform. A typical test arrangement is shown below: A Tektronix CT-2 or Integrated Sensor...
  • Page 19: Waveform Distortions

    where V is the voltage drop across the diode, R is the parasitic resistance of DIODE DIODE the diode, and R is the resistance of the series resistor. R should be SERIES SERIES DIODE equal to 6.2 Ohms for the AVO-5C-TA, and 1.5 Ohms for the AVO-5C-TB. Aside from providing the required termination, the added series resistance may also be used to monitor the output current waveform.
  • Page 20: Basic Pulse Control

    BASIC PULSE CONTROL This instrument can be triggered by its own internal clock or by an external TTL trigger signal. When triggered internally, two mainframe output channels respond to the trigger: OUT and SYNC. • OUT. This is the main output. •...
  • Page 21: Parameter Interaction

    PARAMETER INTERACTION The pulse width, amplitude, and frequency controls may all interact to some extent. If you change the PRF by switching ranges, the output pulse may “disappear” because the pulse width has shifted. Simply adjust the pulse width control until the pulse re-appears.
  • Page 22: Minimizing Waveform Distortions

    In particular, wire-wound resistors should be avoided. PREVENTING DAMAGE The AVO-5C-C may fail if triggered at a PRF greater than 5 MHz, or if the duty cycle exceeds 10%. The lifetime of the switching elements in the pulse generator module is proportional to the running time of the instrument.
  • Page 23: Mechanical Information

    MECHANICAL INFORMATION TOP COVER REMOVAL If necessary, the interior of the instrument may be accessed by removing the four Phillips screws on the top panel. With the four screws removed, the top cover may be slid back (and off). Always disconnect the power cord and allow the instrument to sit unpowered for 10 minutes before opening the instrument.
  • Page 24: Maintenance

    MAINTENANCE REGULAR MAINTENANCE This instrument does not require any regular maintenance. On occasion, one or more of the four rear-panel fuses may require replacement. All fuses can be accessed from the rear panel. See the “FUSES” section for details. CLEANING If desired, the interior of the instrument may be cleaned using compressed air to dislodge any accumulated dust.
  • Page 25: Wiring Diagrams

    WIRING DIAGRAMS WIRING OF AC POWER Mains circuits - hazardous liv e. D o n o t attem pt any repa irs o n thi s i nstrum ent Mount w ith M2.5-0.4 5X12. bey ond the fus e rep l ace m en t proce dures d escri bed in the m a nual .
  • Page 26: Pcb 158K - Low Voltage Power Supply, 1/3

    PCB 158K - LOW VOLTAGE POWER SUPPLY, 1/3 p cb 1 58 k _ ov p p cb 1 58 k _ ov p .sch +1 5V +1 5V +1 5V GN D GN D P-OU T # 1 P-OU T # 1 -1 5 V -1 5 V -1 5 V...
  • Page 27: Pcb 158K - Low Voltage Power Supply, 2/3

    PCB 158K - LOW VOLTAGE POWER SUPPLY, 2/3 8 3 08 3 5 FUSEHO LDER 6 4 04 4 5 -6 TEST-LOO P TEST-LOO P S1 A S1 B, OR D C S2 A, O R DC S2 B 4 3 4- 13 -1 0 0 M C2 0 C1 9 C2 1...
  • Page 28: Pcb 158K - Low Voltage Power Supply, 3/3

    PCB 158K - LOW VOLTAGE POWER SUPPLY, 3/3 R2 1 1 .5 K O Y CAPBANK C2 3 1 N5 3 0 5 1 0 00 u F,3 5 V (P5 16 9 -ND ) L6 27 1 1 HV WA RN ING R1 7 SHO RTS OU T B ASE WHEN C HAR GING.
  • Page 29: Pcb 168B - High Voltage Dc Power Supply

    PCB 168B - HIGH VOLTAGE DC POWER SUPPLY HV WA RN ING HV WA RN ING 1 N4 9 3 7 1 N4 9 3 7 6 4 04 4 5 -2 6 4 04 4 5 -2 1 N4 9 3 7 1 N4 9 3 7 1 0 0 OY R1 0...
  • Page 30: Pcb 126B - Oscillator And Trigger Circuit

    PCB 126B - OSCILLATOR AND TRIGGER CIRCUIT (OPTIONAL FEATURE) U1 D MTA -8 10 6 D-WW C1 2 C1 0 C1 6 6 .8 u F 4 .7 K 0 .1 u F 0 .1 u F GN D U2 A SN7 4 LS1 4 U2 B +1 5V...
  • Page 31: Main Wiring

    OUT A C ONN3 OUT B -1 5V +15 V AVO-5C-C-P Printed Revision 29-Mar-2007 C L 4 Z:\m jc f i le s \c irc u its \ AV O\a vo .D d b - A VO-5 C -C -P\5 C -P V1 .S C H...
  • Page 32: Performance Check Sheet

    PERFORMANCE CHECK SHEET...

Table of Contents