Do you have a question about the BEV25WiNCC and is the answer not in the manual?
Questions and answers
Summary of Contents for BEVOi BEV25WiNCC
Page 1
Window Air Conditioner BEV25WiNCC Thank you for purchasing this Window Air Conditioner. Before operating this unit, please read these instructions completely and keep the manual ready for further reference.
CONTENTS Important Safety Instructions Electrical Requirements Packing List Installation & Assembly Instructions Using Your Air Conditioner Care and Cleaning Troubleshooting...
Important Safety Instructions Before installing and using your air conditioner, please read this owner's manual carefully. Store thismanual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this user manual.
Page 4
Introduction to Refrigerants R32 The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of erant is combustible and odorless. Moreover, it can burn and explode under certain condition. However, there will be no risk of burning and explosion if you comply with the following table to install your air conditioner in a room with an appropriate area and use it correctly.
Electrical Requirements Warning Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove the ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.
Page 6
LCDI Power Cord and Plug This air conditioner is equipped with an LCDI (Leakage Current Detection and Interrup- tion) power cord that is requiredby UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged and leakage occurs, power will be disconnected from the unit.
Packing List POWER COOL SLEEP SPEED TIMER DISPLAY AUTO MODE ONLY Window Air Conditioner *1 Remote Control *1 Top Rail *1 Lock Frame *2 Sash Lock Side retainers *2 Filler Panels *2 (Two holes) *1 (With "Left"&"Right"remark on the front face) 1/2"Screws *2 5/16"Screws *10 Window Sash Seal...
Installation & Assembly Instructions Some assembly is required for your new air conditioner. Please read and follow these instructions carefully. This air conditioner is designed to be installed in a standard double-hung window with a window width between 28" and 41" (712mm-1041 mm) for 18000btu. a window width between 30"...
Prepare Air Conditioner for Installation Warning Excessive Weight Hazard Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury. Unpack the Air Conditioner Remove Packaging Materials Gently handle the air conditioner while unpacking the unit.
Page 10
Remove control panel screw Remove the control panel two screws from the front panel. Remove side screws Remove six screws from the top side and left-right side of the cabinet. Remove chassis IMPORTANT: To avoid damage, do not pull or lift near the top of the unit. Hold the cabinet while pulling on the base handle to carefully remove the unit.
Page 11
Install Air Conditioner in Window Warning Excessive Weight Hazard Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury. Important Be sure your air conditioner does not fall out of the opening during installation or removal.
Install Support Brackets Note: Attach curtains to the air conditioner cabinet before placing the air conditioner in window. Mark bracket location Hold each support bracket flush against the outside of the window sill. Tighten each bracket to the bottom of the cabinet with 1/2” flathead bolt with locknut. With a pencil, mark the bracket where the top of the window sill meets the bracket.
Page 13
Install Air Conditioner in Window Warning Warning Install the Chassis into the Cabinet Excessive Weight Hazard Use two or mare people to mave and install air conditioner. Failure to do so can result in back or other injury. Reinsert air conditioner chassis Important: To prevent damage to the unit, do not push on the controls or finned coils.
How to Install NOTE: Top Rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of (5/16"). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels forany reason, this pitch to the rear must be maintained! Place unit on floor, a bench or a table.
Page 15
Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (Fig.5). Carefully close the window behindthe top rail of the unit. (Suggest to keep a down- ward oblique, to let accumulated rain water to drain out, from back side of the unit bottom.) Extend the side panels out against the window frame (Fig.6).
Page 16
Drive 1/2" (12.7mm) locking screws throughframe holes into window sash (Fig.9 Fig10). Fig.9 Fig.10 To secure lower sash in place, attach right angle sash lock with 3/4" (19 mm) screw as shown (Fig.11). Cut foam seal and insert in the space between the upper and lower sashes (Fig.12). Fig.11 Fig.12...
If AC is Blocked by Storm Window Add wood as shown in Fig.13, or remove stormwindow before air conditioner is installed. 19 '' MIN for 18 000btu 19 1/2'' MIN for 24 000btu SASH 1/2'' MIN Board thickness as required, for proper pitch to rear, along 1/2'' MIN entire sill.
Page 18
Assembly & Installation-thru-the-wall(Cont.) Carefully measure and cut an opening with the following dimensions depending on your model. WIDTH“X”= inside model plus twice the thickness of the framing material used. HELGHT “Y”= inside model height plus twice the thickness of framing material used. Model 22K/24K Inside Frame Height...
Page 19
Prepare and Install the Cabinet Slide the chassis from the cabinet. Refer back to the REMOVE CHASSIS instructions(Page 6 and 7) in the WINDOW MOUNTING SECTION. Place the cabinet into the opening with the bottom rail resting firmly on the bottom board of the wood frame.
Masonry Construction Cut or build a wall opening in the masonry wall similar to the frame construction (refer to the THRU-THE-WALL installation for a wall thickness greater than 8 1/2”). Secure the cabinet in place using masonry nails, or masonry anchor screws. Or, build a frame using the instructions found in the THRU-THE-WALL installation section.
Introduction to Refrigerants R32 Before installing the appliance, you must read the manual carefully to get the safety information and notes. When filling the combustible refrigerant, any of your rude operations may cause serious injury or injuries to human body or bodies and object or objects. A leak test must be done after the installation is completed.
Please note that: The installation site should be in a well-ventilated condition. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding, smoking, drying oven or any other heat source higher than 548°C which easily produces open fire.
AUTO AUTO SPEED MODE 1. Digital Display: Without timer setting, the operation mode is Cooling, Dry, Fan and Auto, and the set temperature will be displayed. Time will be displayed under timer setting. Button: Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer.
Page 24
Auto Mode: In AUTO mode the unit automatically chooses the mode of operation (COOL, or FAN). In this mode the temperature is set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit). 5.
10. Directional Louvers: To direct the airflow, use the horizontal wheel to control the horizontal direction, control the vertical direction. Air Deflector Horizontal Wheel Air Deflector REMOTE CONTROL POWER COOL SLEEP SPEED DISPLAY TIMER AUTO ONLY MODE 1. POWER Turn the air conditioner on and off. 2.
Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61°F ~88°F or 16°C ~31°C . 4. Sleep Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on.
9. ECO When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn off once the room is cooled to the user set temperature. The unit will turn back on when the room temperature rises above the user set temperature.
Wear and Tear To minimize wear and tear on the air conditioner, always wait at least 3 minutes before changing modes. This will help prevent the compressor from overheating and the circuit breaker from tripping. Cabinet Cleaning To clean the air conditioner cabinet: Unplug the air conditioner to prevent shock or a fire hazard.
Troubleshooting Problem Possible Causes Solutions Make sure the air condition- The air conditioner is unplugged er plug is pushed completely into the outlet. Check the house fuse/circuit The fuse is blown/circuit breaker breaker box and replace the is tripped fuse or reset the breaker. The unit will automatically re-start when power is restored.
Page 30
Problem Possible Causes Solutions Please allow time for the room The room may be too warm to cool down after turning on the air conditioner. The Air Conditioner does not cool as it Check for open furnace Cold air is escaping should registers and cold air returns.