North Atlantic 65DL2 Manual

On-board programmable excitation supply

Advertisement

UP TO 12 CHANNELS of 3-WIRE LVDT/RVDT STIMULUS
F
EATURES
Programmable output voltage
On-board optional programmable excitation
Continuous background BIT testing
Extensive diagnostics
Wideband 360 Hz to 20 kHz
Optional Ratiometric or Self leveling conversion
Message based C size VXI card for with Mate CIIL
VISA Plug-and-Play Driver Library available.
Dynamic address configuration
VXIbus data rate of 2 megabytes/sec
Data is processed within 100 s
Occupies only a single slot
No adjustments or trimming
D
ESCRIPTION
This single slot, message based VXIbus instrument can be populated with either one or two daughtercards. Each
daughtercard can provide up to eight (8) LVDT/RVDT 3-wire with wraparound self test and an optional
programmable excitation supply. Currently, a total of sixteen (12) 3-wire channels and an excitation supply can be
provided within one single slot enclosure (see part number). An optional feature permits programming each output
for either ratiometric or self-leveling (fixed) mode. In the ratiometric mode, the output voltage will vary
directly/proportionately with the excitation voltage. In the self-leveling (or fixed) mode, the output voltage is
programmed and remains constant regardless of excitation voltage. Standard/default is ratiometric. This card is a
uniquely versatile instrument because each excitation input and output voltage is programmable. In addition, each
channel may be programmed to be controlled by an external DC voltage (see part number).
North Atlantic Industries, Inc.
110 Wilbur Place, Bohemia, NY 11716
ON-BOARD PROGRAMMABLE EXCITATION SUPPLY
631.567.1100/631.567.1823 (fax)
www.naii.com
Twelve (12) LVDT/RVDT STIMULUS Channels
VXIbus
09/11/12
Cage Code: 0VGU1
65DL2
Model
65DL2_A001_Rev_A3
Page 1 of 19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 65DL2 and is the answer not in the manual?

Questions and answers

Summary of Contents for North Atlantic 65DL2

  • Page 1 Standard/default is ratiometric. This card is a uniquely versatile instrument because each excitation input and output voltage is programmable. In addition, each channel may be programmed to be controlled by an external DC voltage (see part number). North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12...
  • Page 2: Specifications

    "C" size (13.386" x 9.187") with 1.2" pitch. (349mm x 234 mm) with 30 mm pitch Weight: 4.3 lbs. (1.95 Kg) Calibration intervals: No calibration is required. Connectors: Mating connectors are not supplied. North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com Cage Code: 0VGU1...
  • Page 3 Output LOADED – (adds per channel) 1.6 mA per 1 mA (load) Excitation Module 110 mA Excitation LOADED – (adds per channel) 275 mA per 1 VA (load) North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com...
  • Page 4 Va-Vb = -10V Va-Vb = Va-Vb = Va = Va = Va = Vb = Vb = Vb = North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com Cage Code: 0VGU1 Page 4 of 19...
  • Page 5: Front Panel Status Indicators

    128 (MSB) SW1, position 8=1 (OFF) SW1, position 8=0 (ON) SW2 SW1 Not Used Ready Access Failed Test Factory Use 65DL2 Bottom View RONT ANEL TATUS NDICATORS Status Indicators Function READY Indicates that unit is ready to accept commands ACCESS Indicator is lit when VXI bus controller sends or reads a message or status.
  • Page 6 CHN SET POSN DLN.A Out Gain DC Control DLN.B Out If <= 8 channels CHN POSN EXT/INT CLS/OPN :CHN North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com Cage Code: 0VGU1 Page 6 of 19...
  • Page 7 EXT Note: * SET<b>OUTM<b>FIXD sets to Self Leveling Output. RTIO is for Ratiometric output. ** SET<b>RSRC<b>INT sets ALL channels to internal reference source. Reference sources for individual channels cannot be set individually. North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com...
  • Page 8: Error Message

    Open Isolation Relays Input sequence of voltages to each cannel from internal source Perform measurements Compared with stored values Max Self-test time = 60 seconds North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com...
  • Page 9 IN_PHASE Native command added to support output phase programming where TRUE configures output for Va – Vb = K and FALSE configures output for Va + Vb = K North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com...
  • Page 10 See FNC Command Format <MODIFIER> VOLT or VRMS Output Voltage REFV Reference Voltage FREQ Frequency POSN Output Position, Center = 50% North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com Cage Code: 0VGU1 Page 10 of 19...
  • Page 11 IST <CR><LF> confidence CNF<CR><LF> Confidence test requires up to 60 seconds before results are available Optional field or structure field repeated as often as required North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com...
  • Page 12 10. “F07ACSnn (MOD): NO SPACE”; 11. “F07ACSnn (MOD): BIT FAIL”; 12. “F07ACSnn (MOD): MESSAGE OVERFLOW”; 13. “F07ACSnn (MOD): MESSAGE SYNTAX ERROR”; Where nn is the channel number North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com...
  • Page 13 Programming Examples Provided below are two programming examples. The 65DL2 is programmed using command strings of ASCII text, or command messages. These messages are displayed in quotes for convenience. Example to set channel 0 for full 10 Vrms reference external, 10 Volts Line-Line and Full Scale (FS) position (100%) SET RSRC EXT sets ALL channels to external references sources.
  • Page 14 PHASE ANGLE VOLTMETER NAI 2250 RELAY CARD REFERENCE SOURCE Serial NAI 5300 IEEE IBM Compatible VXI RACK W/SLOT 0 CARD North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com Cage Code: 0VGU1 Page 14 of 19...
  • Page 15 For 12 channels units, 8 channels are on J1 and 4 channels are on J2 (channels 9 thru 12 are referenced on J2 as respective Ch0 thru Ch3). DO NOT CONNECT TO ANY UNDESIGNATED PINS. North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12...
  • Page 16 3-WIRE OUTPUT R = One 5 VA Excitation supply PROGRAMMING M = Mate CIIL Notes: Option available on 8 channel configuration only North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com Cage Code: 0VGU1...
  • Page 17: Installation

    Contact your local Sales Representative for any technical assistance. Alternatively, contact the Factory at: North Atlantic Industries 110 Wilbur Place Bohemia, NY 11716 Telephone: (631) 567-1100 Fax: (631) 567-1823 Web: www.naii.com North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com Cage Code: 0VGU1 Page 17 of 19...
  • Page 18 ECLARATION OF ONFORMITY NORTH ATLANTIC INDUSTRIES, INC. 110 WILBUR PLACE, BOHEMIA, NY 11716-2416 declare under our sole responsibility that the following products 65 SERIES To which this declaration relates is in conformity with the following standard(s) or other normative document(s):...
  • Page 19: Revision Page

    Agile-format / Added self-leveling mode description / Removed SW2 addressing references 05/19/08 Release to Agile 05/29/08 Clarified available part number configuration option(s) / limited to 12 CH max. 09/11/12 North Atlantic Industries, Inc. 631.567.1100/631.567.1823 (fax) 09/11/12 65_DL2_A001_Rev_A3 110 Wilbur Place, Bohemia, NY 11716 www.naii.com...

Table of Contents