ENDA E-200 INSTRUCTION MANUAL
Caution for UL/cUL requirements
- The ENDA E-200 inverter UL file number is E205705.
Confirmation of UL listing can be found on the UL website : www.ul.com
- Do not connect or disconnect wiring, or perform signal checks while the
power supply is turned ON.
- There are live parts inside the inverter. Never touch the printed wiring
board(PWB) while the power supply is turned ON.
- [Warning] The bus capacitor discharge time is 5minutes. Before starting
wiring or inspection, switch power off, wait for more than
5minutes, and check for residual voltage between terminal
P(+) and N(-) with a meter etc., to avoid hazard of electrical
shock.
- [Short circuit rating] This inverter is not suitable for use on a circuit
- [Over speed protection] This inverter does not provide over speed
- [Over load protection] This inverter provides motor over load protection.
- [Environment]
Ambient temperature
Ambient humidity
Storage temperature
Vibration
Altitude
Ambience
Pollution Degree
capable of delivering more than 5,000RMS
symmetrical amperes, 480volts for HF type and 240
volts for SFand LF type maximum.
protection.
Over load protection level is 20¡200% of full load
current. The protection level may be adjusted by
code b07. Refer to the E-200 user guide or
catalogue.
Maximum Surrounding Air Temperature 40¡
90% RH or less(no condensing)
- 0? 0?
2 6
5.9 or less
§
Altitude 1,000m or less
Indoors(No corrosive and flammable gases,
oil mist, dust and dirt)
0.4~3.7kW : Pollution Degree 3
5.5~7.5kW : Pollution Degree 2