pivotal HY2002 HYLO IAT User Manual

Advertisement

Quick Links

HY2002 HYLO IAT Elevating
Table
User Manual
Applies to the following Models:
HY2002
Important! This User Manual contains important information for the user of the product. All who
use this product should review and completely understand its contents. Remember to keep this manual
in a place where it is always available to those using the product.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HY2002 HYLO IAT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for pivotal HY2002 HYLO IAT

  • Page 1 HY2002 HYLO IAT Elevating Table User Manual Applies to the following Models: HY2002 Important! This User Manual contains important information for the user of the product. All who use this product should review and completely understand its contents. Remember to keep this manual...
  • Page 2: Table Of Contents

    Table of Contents: Introduction: ................................... 2 Safety Precautions & Definitions: ............................3 Symbols: ....................................4 Installation & Unpacking: ................................ 5 Technical Specifications: ................................. 6 Operation: ....................................7 Preventative Maintenance:..............................9 Upholstery Cleaning & Care: ..............................9 Service: ....................................10 Troubleshooting: ................................... 10 Replacement Parts: ................................
  • Page 3: Safety Precautions & Definitions

    • Follow preventative maintenance instructions provided in this manual. • Ensure all components have been inspected for damage and are fully functional. • Inspect cables and connectors before each use. • If you need service assistance contact Pivotal Health Solutions at 1-800-743-7738. HYLO IAT Elevating Table...
  • Page 4: Symbols

    Indicates the device manufacturer. WARNING: Under no circumstances should the table be modified from its original design. Contact Pivotal Health Solutions if you need help with service. DANGER: Possible explosion hazard if used in the presence of flammable anesthetics. HYLO IAT Elevating Table...
  • Page 5: Installation & Unpacking

    If freight was arranged by Pivotal Health Solutions, note any damage on the Bill of Lading before signing acceptance of product and notify Pivotal Health Solutions right away. Failure to inspect for shipping damage prior to signing for the product may affect your warranty.
  • Page 6: Technical Specifications

    Expected Life: This product has an approximate expected life time of 10 years when correctly handled, serviced, and inspected in accordance with these instructions. Design and Quality: Pivotal Health Solutions is certified in accordance with ISO 13485, the standard for the medical device industry.
  • Page 7: Operation

    Operation: WARNING: Use of accessories and cables other than those specified or provided by Pivotal Health Solutions could result in increased electromagnetic emissions or decreased electromagnetic immunity and result in improper operation. WARNING: Not for patient transport. CRUSH HAZARD: Powered components used to elevate and lower this table present a potential crush hazard.
  • Page 8 3) Once treatment is finished to remove patient lower the table to its lowest horizontal position. Lower the table by pressing and holding the down arrow under the raise/ lower icon. 4) You can now safely remove the patient from the table, or you may choose tilt the table vertical so patient can step of the table in the vertical position.
  • Page 9: Preventative Maintenance

    • Ensure all locking components lock properly. • Note: This table requires no lubrication. • Contact Pivotal Health Solutions with questions or concerns. Upholstery Cleaning & Care: CAUTION: Read carefully, improper cleaning will void the warranty. Never use alcohol-based cleaning agents.
  • Page 10: Service

    A therapy table is considered a medical device by the Food and Drug Administration. Therefore, it is necessary that Pivotal Health Solutions, Inc. be notified if the table is sold, destroyed, or otherwise disposed of. Please notify in writing providing your name and the serial number of your table to:...
  • Page 11: Replacement Parts

    Replacement Parts: (NOT ALL COMPONENTS ARE SHOWN) DROP ASSEMBLY S2778 HYLO IAT Elevating Table...
  • Page 12: Warranty

    Pivotal Health Solutions reserves the right to inspect claimed defective products. No returns, replacements or repairs may be made without prior written consent. Please do not return any product to Pivotal Health Solutions or its service center without first contacting Customer Service for a Return Authorization number. Products returned without a Return Authorization number will be refused back to the customer at their expense.
  • Page 13: Manufacturer Information

    Manufacturer Information: (in US) 800-743-7738 (international) 011-1-605-753-0110 Pivotal Health Solutions, Inc. 3003 9 Ave SW, Fax: 605-882-8398 Watertown, SD 57201 Email: service@pivotalhealthsolutions.com World Wide Web: www.pivotalhealthsolutions.com Rev B 03/10/21 HYLO IAT Elevating Table...