Kenton CR-80 Instruction Manual

Co2 incubator

Advertisement

Quick Links

CO2
Incubator
CR-80/160
(LCD display)
Instruction manual
Manufacturer: Kenton Apparatus Limited
Factory Add:
No.2 Hualong Road, Renhe Town Alley Baiyun District
Canton
China
Ph: 0086-020-36246586 36247961
Website:
www.kentonchina.com
Emial:
kenton@kentonchina.com
Official Accounts:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CR-80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kenton CR-80

  • Page 1 Incubator CR-80/160 (LCD display) Instruction manual Manufacturer: Kenton Apparatus Limited Factory Add: No.2 Hualong Road, Renhe Town Alley Baiyun District Canton China Ph: 0086-020-36246586 36247961 Website: www.kentonchina.com Emial: kenton@kentonchina.com Official Accounts:...
  • Page 2 Notices  In order to ensure safety to use this equipment, please read this manual carefully Make sure put this manual in convenient place for later use  Our company doesn’t provide a safe guarantee if not use according  to the instruction manual This manual only for user and authorized technician, please preserve...
  • Page 3: Safety Notices And Warnings

    Safety notices and warnings This manual has important use information , please comply. Make sure put this manual in convenient place for later use. The symbols appear to the equipment and the manual, in order to you can safely and correctly operate this equipment ,avoiding the possible harm ●...
  • Page 4 Safety operation and Preventive action warning Don’t place this equipment outdoors. if wet it in the rain, it will cause creepage and electric shock. Only professional person have qualification to install this equipment. If not,It will cause electric shock or fire. ought to place this equipment on the firm ground in case turn over.if not, it will cause injury because turn over or capsize Don’t place equipment in damp atmosphere .or it will cause creepage or electric shock...
  • Page 5 Safety operation and Preventive action warning Don’t touch any electric components or switch in wet hand ,or it will cause electric shock make sure not to suck any drug and airborne particle around the equipment when maintaining ,or it will be harmful for your health Don’t let water splash the equipment ,or it will cause electric shock or short circuit Don’t put container which is full of water on the top of equipment ,or it will...
  • Page 6 Safety operation and Preventive action notice equipment scrap disposal should be done by relevant person .ought to dismount door in case cause stifling Don’t put packing plastic bag in the place children can get ,or it will cause stifling please clean the dust on the power plug and then insert it into power socket tightly .or it will cause heating or strike sparks need to check temperature ,humidity ,segment and timing and other setting value when reopen equipment if happen to cut off power supply...
  • Page 7 Instruction(application ,working principle, technical parameters ) application CR series carbon dioxide incubator is an advanced instrument for cell, tissue and bacterial culture, which is a key equipment necessary for immunology, oncology, genetics and bioengineering. Used in microbiology, medicine, pharmaceutical, environmental protection, food, animal husbandry and other scientific fields of research and production.
  • Page 8 Main technical index Model CR-80 CR-160 argument Temperature control RT+5℃~60℃ range Temperature fluctuation ≤±0.5℃(37℃) Temperature uniformity ≤±0.8℃ Temperature recovery (When the door is restored to 37℃ for 30 seconds) ≤8min time CO2 control range 0~20% concentration (When the door is restored to 5% in 30 seconds) ≤1.2min...
  • Page 9 Structure Components 1 电器盒 2 电源开关 3 485接口 4 控制面板 5 进水口 6 搁板 7 放水口 8 溢水口 9 门磁封条 10 试验孔 11 挡水条 12 玻璃门钩 13 玻璃门 1.Power supply box 2.power switch 3.485 interface 4.Control panel 5.Water inlet 6.shelves 7.water outlet 8.overflow 9.Door seal magnetic strip 10.
  • Page 10: Equipment Installation

    Equipment installation Installation site For proper operation and optimal performance, install the equipment in a location that meets the following conditions: Note: Ambient temperature 10~30℃; Relative humidity below 70% ■ A location that is protected from direct sunlight. Do not install the device in direct sunlight. Installation in direct sunlight may cause the device to fail to achieve the expected performance.
  • Page 11: Preparation Before Operation

    Do not install the equipment in a place with flammable or volatile substances, or it may cause an explosion or fire. Or it may cause leakage, electric shock or damage to the equipment due to corrosion. Equipment installation installation 1.Take off packing materials Take off packing all materials ,open the door for ventilation .
  • Page 12 2. Turn the knob of the inner glass door clockwise by hand, and then turn it to the right to open the inner door; 3. Take out the shelf accessories inside the equipment, wipe the shelf and the inner wall of the box with gauze for cleaning;...
  • Page 13: Operation

    Operation 1. Main interface 2.1 Key Description I co n Na m e De s c r i p t i o n Cl i c k th e po p - u p di a l o g bo x to m a k e th e [ St a r t ] s y s t e m ru n ;...
  • Page 14 2.2 .1 Res er v a t io n At th e [p a r am e ter set ] - > [ t im e pa r am et er ] in te r f ac e, th e us e r ca n set th e res e r v ati o n tim e , if th e res er v at io n tim e is gr eat er th an th e cu r r en t tim e , in th e [m o n it o r in ter f ace ] , cli ck th e [r u n ] ke y, th e sy s t em wil l fir s t en ter th e [r es er v at io n wai ti n g ] st at e;...
  • Page 15: Alarm Function

    ste r il iz ati o n par a m et er s ] . Th er e ar e th r ee ste r il iz ati o n meth o d s : ul tr a v io l et ste r il iz ati o n , hu m i d he at ste r il iz ati o n an d hi g h tem p er a tu r e st er i li zat io n .
  • Page 16 Al a r m ty p e Al a r m De s c r i p t i o n W h e n th e te m p e r a t u r e of th e m a i n te m p e r a t u r e s e n s o r fa i l s , Ma i n th e m a i n te m p e r a t u r e ov e r f l o w al a r m is ge n e r a t e d , th e te m p e r a t u r e...
  • Page 17: Menu Interface

    2.5 Real-time curves Th e us e r can cli ck on [cu r v e] or sli d e th e sc r een to th e lef t to en t er th e [r e al- t im e cu r v e] in te r f ac e.
  • Page 18: Operational Examples

    4.2 Procedure model In pr o g r am mo d e, mu l ti p le tem p e r at u r e, co n cen t r at io n co n tr o l st ep s an d co n tr o l tim e of ea ch ste p can be se t;...
  • Page 19: History Data

    Wh e n th e tem p e r at u r e ris es to 25 . 0 ± 0.5 ℃ fo r 1 ho u r an d 30 mi n u te s, th en to 35 .0 ℃ fo r 1 ho u r, se t as fo ll o ws : Se t Nu m b e r of Se t...
  • Page 20 No . Co n t e n t De s c r i p t i o n [R e t u r n ] Ke y Cl i c k to re t u r n to [D i r e c t o r y In t e r f a c e ] ; [H i s t o r y Cu r v e ] Cl i c k to en t e r th e hi s t o r y cu r v e in t e r f a c e ;...
  • Page 21: Parameter Set

    Z o o m in an d Cl i c k on th e zo o m or zo o m na r r o w th e cu r v e cu r v e Le f t s h i f t , ri g h t Cl i c k th e le f t or ri g h t cu r v e sh i f t 6.Parameter set...
  • Page 22: Time Parameters

    It is us u a l l y us e d to co r r e c t th e er r o r Ma i n te m p e r a t u r e ca u s e d by hi g h te m p e r a t u r e s l o p e m e a s u r e m e n t .
  • Page 23: Other Parameters

    E n d of op e r a t i o n Bu z z i n g pr o m p t ti m e af t e r ru n n i n g . (0 ~ 3 0 0 s) 6 0 Pr o m p t ti m e No t e :0 m e a n s co n t i n u o u s ca l l .
  • Page 24 Na m e Fu n c t i o n I n i t i a l va l u e (s e t ra n g e ) s t e r i l i z a t i o n Ti m e ra t i o re g u l a t i o n .
  • Page 25 Na m e F u n c t i o n I n i t i a l va l u e (s e t ra n g e ) W h e n [c o n c e n t r a t i o n me a s u r e m e n t va l u e In f l a t a b l e Tu r n o ff ≥...
  • Page 26 Op e n do o r he a t i n g an d cl o s i n g : th e do o r al a r m is m o n i t o r e d op e r a t i o n , th e co n t r o l l e r s t o p s he a t i n g ou t p u t ;...
  • Page 27 Alarm and security features ● Temperature sensor fault alarm: The screen displays: -- words, indicating that the temperature sensor or controller itself is faulty. ● Temperature upper limit alarm: When the measuring temperature exceeds the set temperature by 1 degree, the heating will stop working, and the instrument alarm lamp will light up and the alarm sound will ring continuously.
  • Page 28 heating temperature will cause damage. Do not lean against the glass door or put incorrect pressure on it, which may cause injury to personnel. Do not lean on the equipment to prevent injury or equipment damage caused by equipment tipping over or door damage. If the equipment fails, it should be repaired by professional personnel or contact the sales department of the factory.
  • Page 29: Troubleshooting

    ■ Data is missing or incorrect Please check if data communication equipment rate and format is accordance. Trouble shooting handling Trouble shooting Sensor fault ·The temperature sensor is abnormal. Check whether the indication temperature sensor is in good condition. Model PT100。 (-...
  • Page 30: Specification

    Specification Name CR series C02 incubator Model CR-80 CR-160 Exterior Dimension 755×550×547 905×610×687 (H * W * D) Interior Dimension 500×400×400 650×460×540 (H * W * D) Effective volume 160L Input power 500W 650W Shell Cold-roll steel sheets with powder coat treatment...
  • Page 31: Wiring Diagram

    Wiring diagram...
  • Page 32: Packing List

    Packing List Name Quantity Note Finish product instruction manual Certificate of conformity 80L/2 pieces 、 shelf 160L/3 pieces Feed water tray Gas pipe 2 meters Charging pipe Power cord 300mm long water water tank pipe relief valve...

This manual is also suitable for:

Cr-160

Table of Contents