Maestro timers contain Advanced Programming Mode (APM) features that allow the user to
customize their control to meet their specific needs.
This document serves as a supplement to the instruction sheet. Before entering APM, it is
important to have a good understanding of the features included. For a summary of these features
and further instructions, see the pages corresponding to your product.
Timer Switch (MA-T51MNB)
Timer Indicator
Lights (TIL) 1–5
TIL5
TIL1
Tap Button
B
Raise Rocker
Lower Rocker
FASS Switch
(Front Accesible Service Switch)
Pull tab out for bulb replacement.
1
Application Note #848
Technical Support — 800.523.9466
Revision B
April 2025

Advertisement

loading
Need help?

Need help?

Do you have a question about the MA-T51MNB and is the answer not in the manual?

Questions and answers

Summary of Contents for Lutron Electronics MA-T51MNB

  • Page 1 Application Note #848 Revision B April 2025 Maestro Timer Advanced Programming Mode Maestro Timer Switch Model: MA-T51MNB Overview Maestro timers contain Advanced Programming Mode (APM) features that allow the user to customize their control to meet their specific needs. This document serves as a supplement to the instruction sheet. Before entering APM, it is important to have a good understanding of the features included.
  • Page 2 Application Note #848 Glossary Advanced Programming Mode: Explanation of Advanced Timer Features Programming Mode: Entering Main Menu Mode Entering Selection Menu Mode Timer APM Programming Settings Setting 1: Selecting a Preset Option Setting 2: Selecting a Bypass Mode Option Setting 3: Selecting the Load Flash Option Exiting Main Menu Mode Timer Step-by-Step Example Shortcuts and Additional Features...
  • Page 3: Advanced Programming Mode

    Application Note #848 Advanced Programming Mode Explanation of Advanced Timer Features Preset Options: The user has two options for the preset time setting on the timer: locked preset and unlocked preset. Locked Preset: When programmed for a locked preset, the timer will always return to the predetermined “locked” •...
  • Page 4 Application Note #848 Using Timer Advanced Programming Mode Advanced programming mode consists of two modes of operation that the user can interact with. The main menu mode allows the user to select which feature they would like to modify. The selection mode allows the user to change the setting of the feature they selected in the main menu mode.
  • Page 5 Application Note #848 Timer APM Programming Settings Setting 1: Selecting a Preset Option What Does It Do? Preset option determines what timeout setting the timer turns on to when the Tap button is pressed The user has two options for the preset time setting on the timer: Locked Preset and Unlocked Preset Locked Preset: When programmed for a Locked Preset, the timer will always return to the predetermined “locked”...
  • Page 6 Application Note #848 Timer APM Programming Settings (continued) Setting 2: Selecting a Bypass Mode Option What Does It Do? This setting sets the timer level you go to on a button double tap The user has two options for the maximum level of the timer: the “On”...
  • Page 7 Application Note #848 Timer APM Programming Settings (continued) Setting 3: Selecting the Load Flash Option What Does It Do? When enabled, this makes the load do a one second flash when the timer counts down to the one minute mark Default setting: Disabled What Do I Want? If the timer is connected to a lighting load, this provides a more visible indication (connected lighting load will flash) that the...
  • Page 8 Application Note #848 Timer APM Programming Settings (continued) Exiting Main Menu Mode 1. Press and hold the tap button for 4 seconds to exit the main menu. Alternatively, wait 1 minute or pull the FASS and the timer will automatically exit from advanced programming mode. Notes: •...
  • Page 9 Application Note #848 Timer Step-by-Step Example Enter Programming Mode 1. Pull the FASS toward you. 2. Press and hold the button of the product you are programming. 3. Push the FASS back in while continuing to hold the button for about 5 seconds until TIL1 blinks quickly. Continue programming: 4.
  • Page 10: Restoring Default Settings

    Application Note #848 Shortcuts and Additional Features Restoring Default Settings The timer switch can be returned to its original factory settings. This allows the programmer a risk-free experience to try different settings. Default settings Load Flash Disabled Bypass Enabled Preset Option Unlocked (no TILs blinking) To Restore Factory Defaults 1 Pull the FASS into the OFF position...