PLEASE READ ENTIRE INSTRUCTIONS CAREFULLY BEFORE PROCEEDING
Four Easy Steps:
If you need additional assistance: E-mail us at info@feherguard.com or call Monday to Friday 905-876-4766 during business hours 8:30 a.m.
to 5:00 p.m. Eastern Time.
REEL SYSTEM COMPONENTS AND PREPARATION:
Ensure your system has the quantity of cartons shown below, consisting of one
end set and one tube set. 2 people make assembly easier.
Tools required for assembly:
Electric drill
Safety Glasses
Tape measure, Pencil & Scissors
Adjustable Wrench
1 Hex Key
STEP 1: SOLAR REEL PLACEMENT:
A.
Determine the best location for the Reel(s) on the pool (see Fig. 2). The end of the pool is often the preferred
location. On some pools, a mid-point location may be required to prevent dragging the blanket over the deck or
avoid diving boards and ladders. Small blanket extensions may be folded in. Wall mounting is possible by
removing the casters.
B.
Trim blanket to clear inside edges of pool. Upon completion of reel assembly and installation, give blanket a
final trim so that blanket does not touch sides of pool when rolling up.
Fig. 1
STEP 2: TUBE ASSEMBLY
A.
At the determined location, measure the maximum width of cover and add
Insert the End Tubes an equal distance into the Center Tube(s) (see Fig. 3). Always ensure Minimum Insertion of End
Tubes inside the Center Tubes(s) (see Fig. 4). Less than minimum insertion will cause screws to loosen and/or tubes to split.
End Tube
CT20 tube
(16' to 21') (1 carton)
CT24 tube
(20' to 24') (1 carton)
46" Min. Insertion
116" end tube
** CT30 tube
(28' to 31') (2 cartons)
** Extra assembly hardware is included in tubeset carton.
Reel System Carton check list:
FGC/CT20 - 1 end carton and 1 tube carton
FGC/CT24 - 1 end carton and 1 tube carton
FGC/CT30 - 1 end carton and 2 tube cartons
FGC/CT20 - Maximum cover size - 20' x 90' (Max. Cover Weight 125 #)
FGC/CT24 - Maximum cover size - 24' x 80' (Max. Cover Weight 125 #)
FGC/CT30 - Maximum cover size - 30' x 60' (Max. Cover Weight 125 #)
Ensure the minimum of each end tube is inside center tube.
Center Tube
Insert both end tubes equal distance into center tube
and MARK on center tube where inner tubes end
Min. Insertion 18"
96" end tube
Min. Insertion 24"
116" end tube
116" center tube
ASSEMBLY INSTRUCTIONS
COMMERCIAL REEL SYSTEMS
FGC/CT20'
12".
End Tube
Min. Insertion 18"
96" center tube
Min. Insertion 24"
116" center tube
Butt Center Tubes Together
116" center tube
116" Joiner tube
FGC/CT24'
FGC/CT30'
End Carton Parts List:
2 'T' Ends
2 Metal Tube Plugs
4 Casters (4") & 4 Washers & 4 Nuts
Hardware Kit:
(Extra Hardware is included)
15 - 40" Straps
15 Strap plates
15 Plastic Screws
42 #12 tek screws
2 Bolts with nuts
24'
24'
Fig. 2
(Do NOT count pieces which may be folded in).
Fig. 3
96" end tube
116" end tube
46" Min. Insertion
116" end tube
Fig. 4
1 Axle c/w Collar
1 Handle
30'
60'
80'
Plugged tube end
Max. Tube
Length
is 21'
Max. Tube
Length
is 25'
Max. Tube
Length
is 31'