Inkbird C236T User Manual
Inkbird C236T User Manual

Inkbird C236T User Manual

Smart plug-in thermostat timer

Advertisement

Quick Links

C236T
Smart Plug-in
Thermostat Timer
User Manual
(US/EU/UK/AU/FR/JP Plug Optional)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C236T and is the answer not in the manual?

Questions and answers

Summary of Contents for Inkbird C236T

  • Page 1 C236T Smart Plug-in Thermostat Timer User Manual (US/EU/UK/AU/FR/JP Plug Optional)
  • Page 2 Warm tips To quickly jump to a specific chapter page, click on the relevant text on the contents page. You can also use the thumbnail or document outline in the top left corner to quickly find a specific page.
  • Page 3: Table Of Contents

    CONTENTS Overview Cleaning and Maintenance Technical Specifications Important Notes/Warnings Product Diagram Troubleshooting Guide Operational Buttons & LCD Definitions FCC Requirement Operation Instructions Customer Service...
  • Page 4 Please keep this manual properly for reference. You can also scan the QR code to visit our official website for product usage videos. For any usage issues, please feel free to contact us at support@inkbird.com. Wenn Sie eine Bedienungsanleitung in deutscher Sprache benötigen, scannen Sie bitte den QR-Code und besuchen Sie unsere Website, um sie zu erhalten und ein Video über die Verwendung des Produkts zu sehen.
  • Page 5: Technical Specifications

    Overview INKBIRD C236T Smart Plug-in Thermostat Timer supports multiple operation modes—temperature control mode, timer control mode and timer with temperature control mode, and can be widely used for intelligent temperature control in heating, cultivation, seedling, wooden shed and home living, etc.
  • Page 6: Product Diagram

    -40℉~212℉/-40℃~100℃ Temperature Control Range Temperature Display Accuracy 0.1℉/℃ 00:01~99:59 Timer Setting Range Operating Environmental Temperature room temperature Temperature 32~140℉/0~60℃ Storage Environment Humidity 20~80%RH (non-condensing) Product Diagram LCD with white backlight Buttons Output (US/EU/UK/AU/FR/JP plug) Probe (Length: 2m, IP67 waterproof) Input (US/EU/UK/AU/FR/JP plug)
  • Page 8: Operational Buttons & Lcd Definitions

    Operational Buttons & LCD Definitions...
  • Page 9 4.1 Operational Buttons Definitions BUTTONS FUNCTIONS Shortly press to choose from ON/OFF, temperature mode, timer mode and timer with temperature control mode. (1) In temperature control mode, short press to set the START and STOP temperature; long press for 2 seconds to set the general parameters; (2) In modes P01 to P08, short press to start/restart the timer;...
  • Page 10 4.2 LCD Definitions CHARACTERS FUNCTIONS Heating /Cooling Temperature Control Mode: Set START temperature and STOP temperature; when the START temperature is higher than the STOP temperature, the plugged device runs in cooling mode, and when the START temperature is lower than the STOP temperature, it runs in heating mode. The thermostat will automatically switch between heating and cooling mode, and then control the plugged device to work as programmed..
  • Page 11 Countdown OFF Mode: Power off the plugged device at the end of the countdown. Countdown ON&OFF Mode: Power on the plugged device at the end of the START time countdown, and power off the plugged device permanently at the end of the STOP time countdown. Cycle Time with Temperature Control Mode: Power on the plugged device during the START time countdown based on the temperature settings, and then power off during the STOP time countdown.
  • Page 12 Countdown ON with Temperature Control Mode: Power on the plugged device based on the temperature settings at the end of the countdown. Countdown OFF with Temperature Control Mode: Power off the plugged device based on the temperature settings at the end of the countdown.
  • Page 13 Countdown ON&OFF with Temperature Control Mode: Power on the plugged device based on the temperature settings at the end of the START time countdown, and then power off the plugged device based on the temperature settings permanently at the end of the STOP time countdown. Heating function: Stays on when heating Cooling function: Stays on when cooling Child lock...
  • Page 14 Temperature unit: C (Celsius) or F (Fahrenheit). AH flashes when the buzzer sounds. Default: 100℃ Range: -40.0℃-100.0℃/-40.0℉-212.0℉ AL flashes when the buzzer sounds. Default: -40℃ Range: -40.0℃-100.0℃/-40.0℉-212.0℉ Refrigeration delay. Default: 00:00 Range: 00:00~00:10...
  • Page 15 Temperature calibration. Default: 0.0 Range: -4.9℃~4.9℃/-8.8℉~8.8℉ Backlight on/off. Default: OFF Buzzer on/off. Default: ON...
  • Page 16: Operation Instructions

    Operation Instructions 5.1 APP Connection Search for the INKBIRD app on the App Store or Google Play, or you can scan the QR code below to download and install it. Thereafter, open the app, complete the registration and login, and then follow the app's instructions to connect the device.
  • Page 17: Cleaning And Maintenance

    5.3 How to connect Open the INKBIRD app and click “+” on the top right corner to add a device. Then follow the app instructions to complete the connection. Make sure that the device is placed as close as possible to the smartphone and router during the connection process.
  • Page 18: Important Notes/Warnings

    Important Notes/Warnings 1. KEEP CHILDREN AWAY. 2. USE INDOORS ONLY TO REDUCE THE RISK OF ELECTRIC SHOCK. 3. DO NOT CONNECT TO OTHER RELOCATABLE POWER SOURCES OR EXTENSION CORDS. 4. USE IN A DRY PLACE ONLY. 5. DO NOT PLACE NEAR WATER TO REDUCE THE RISK OF ELECTRIC SHOCK. 6.
  • Page 19: Troubleshooting Guide

    Troubleshooting Guide Issues Possible Solutions 1. Check that the power socket is live. 2. Perform a power test: Connect the device into the AC socket, briefly press the button to switch to manual mode, and then briefly press the button to select No output of heating or cooling ON/OFF for testing.
  • Page 20: Fcc Requirement

    FCC Requirement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 21: Customer Service

    This item carries a 2-year warranty against defects in either components or workmanship. During this period, products that prove to be defective will, at the discretion of INKBIRD, be either repaired or replaced without charge. For any problems in use, please feel free to contact us at support@inkbird.com. We will do our best to help you.

Table of Contents