Table of Contents

Advertisement

Quick Links

INSTALLATION, USE AND MAINTENANCE MANUAL
BLUE
LB 3202
USA
English
Manual
DOC. NO.
H 83554 00
EDITION 1
05 03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LB 3202 and is the answer not in the manual?

Questions and answers

Summary of Contents for Necta LB 3202

  • Page 1 INSTALLATION, USE AND MAINTENANCE MANUAL BLUE LB 3202 Manual English DOC. NO. H 83554 00 EDITION 1 05 03...
  • Page 3 DICHIARAZIONE DI CONFORMITA’ DECLARATION OF CONFORMITY DÉCLARATION DE CONFORMITÉ KONFORMITÄTSERKLÄRUNG DECLARACIÓN DE CONFORMIDAD DECLARAÇÃO DE CONFORMIDADE VERKLARING VAN OVEREENSTEMMING INTYG OM ÖVERENSSTÄMMELSE OVERENSSTEMMELSESERKLÆRING YHDENMUKAISUUSTODISTUS Valbrembo, 03/05/2001 Dichiara che la macchina descritta nella targhetta di identificazione, è conforme alle disposizioni legislative delle direttive: 89/392, 89/336, 73/23 CEE e successive modifiche ed integrazioni.
  • Page 5: Table Of Contents

    PAGE 16 DISPLAYING THE TEMPERATURE PAGE 16 FILLING THE CHANGE TUBES PAGE 17 DISPLAYING THE STATISTICS PAGE 17 PRINTING THE STATISTICS PAGE 17 RESETTING THE STATISTICS PAGE 17 GENERAL COUNTER PAGE 17 © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 6: Introduction

    It also assists in spare parts management. Product code Serial number Model Frequency Operating voltage Current Absorbed power Water mains characteristics Boiler data Fig. 1 © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 7: Positioning The Vending Machine

    - adequately dispose of all containers of the products used for loading and cleaning the machine; - switch the machine off during periods of inactivity, thus achieving considerable energy savings. Power supply voltage Power supply frequency Installed power © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 8: Power Consumption

    - Pump with timer protection tions. - Overheating protection for: Doser units Pump Mixers Capsule release magnet - Fuse protection for: Main electrical circuit Board power supply transformer © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 9: Changeable Combination Lock

    Generally, only the use key (silver) is used, while the combination change keys (gold) can be kept as spares. Do not use the change key for normal opening, as it may damage the lock. Fig. 3 © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 10: Loading And Cleaning

    At installation the hydraulic circuits and the parts in contact with foodstuff should be fully sanitised to remove any bacteria which might have formed during storage. © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 11: Controls And Information

    Press selection buttons No. 3 and No. 6 in a short se- quence to automatically start filling the machine hydraulic system. NOISE LEVEL The continuous, weighted equivalent acoustic pressure level is below 70 dB. © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 12: Mixer Cleaning

    THE COFFEE UNIT Every time coffee is refilled, or at least once a week, any powder residue should be removed from the external parts of the coffee unit, especially from the capsule loading zone. © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 13: Installation

    It is good practice to install the water supply tap outside the machine in an easily accessible position. Fig. 8 1 - Door lock bolt 2 - Door lock 3 - Door switch 4 - Container bracket © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 14: Overflow Device

    Fig. 10 1 - Water inlet union (3/4" gas) 2 - Water supply hose 3 - Overflow hose Fig.11 1 - Lift cover 2 - Cable clamp 3 - Power supply cable © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 15: Installing The Payment System

    Versions with internal tank For models with an internal tank, when the machine is first switched on, the installation procedure MUST BE carried out manually (see relevant chapter). © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 16: Operation

    If the 11 - Release control lever capsule is still detected, the coffee-based selections are 12 - Release magnet blocked with a “Coffee release” failure. 13 - Capsule release tube © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 17: Coffee Dispensing Cycle

    Fig. 15 ing the ground coffee inside the capsule. 1 - Hydraulic piston 2 - Brewing piston 3 - Capsule ejector levers 4 - Ejector piston stem © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 18: Checking And Adjusting The Machine Settings

    The boiler temperature is controlled by the software (92°C perature are directly controlled by the microprocessor. by default) and can be adjusted directly from a menu. To adjust them it is therefore necessary to follow the programming procedures. © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 19: Operating Modes

    “Insert capsule” Selection made before the message “Sel. disabled”, indicating a disabled inserting a capsule selection, will be displayed. © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 20: Special Functions

    - the push-button panel is checked; the machine dis- plays the number of the button which must be pressed and waits for this to be done before going to the next button (number 9 corresponds to the cleaning button). © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 21: Filling The Change Tubes

    4 - counters by coin type MDB statistics Total cash Inserted coins Returned coins Inserted bills Amount of total sales Amount of total cash Amount of cashless sales Money charge Amount of discounts © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 22: Programming

    "Config. selections" defining the accessories to be dispensed by each single button “Special sales” Free Vend and Jug Facilities “Set date/time” setting date and time “Set wash” setting the wash time © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 23: Programming The Water And Powder Doses

    If the capsule is still detected after two release attempts, the coffee-based selections are blocked with a “Coffee re- lease” failure. © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 24: Programming The Prices And The Push-Button Status

    It is possible to set a limit to the total amount of change returned by the coin mechanism when pressing the coin return button or after a single product selection. Any credit exceeding the amount programmed with this function will be cashed. © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 25: Initialising

    Type of doses to be used for the selections - the “post-whipping” time is eliminated. “Layout” Layout of containers and selection menu from the available ones “Tank” Water supply from the mains or from a tank © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 26: Selection Counter

    After these functions are enabled, do as follows: Fig 21 - while in normal operating mode, press button “8” for a few seconds; - enter the password that was just set; - make a selection within 10 seconds. © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 27: Setting The Clock

    (0 to 99) (dispensed at less than 2 minutes intervals) after which the machine will not dispense other selections until the boiler reaches the correct temperature. With the value set to 0 (default) the function is disabled. © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 28: Introduction

    9 - Ratiomotor handle 10 - Reference notches 11 - Piercing filter 12 - Slide 13 - Capsule ejector lever 14 - Rod 15 - Rod snap rings 16 - Hydraulic piston quick coupling © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 29: Sanitising The Mixers And Foodstuff Circuits

    Fig. 23 1 - Powder feeder 2 - Powder funnel 3 - Powder deposit box 4 - Water funnel 5 - Feeder 6 - Mixer impeller © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 30: Regeneration Of The Softener Unit

    2 - Cap - clean all parts in a solution of hot water and sanitising 3 - To the machine products and dry thoroughly. 4 - Softener unit 5 - To the drain © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 31 2 - Release control lever 3 - Release device 4 - Capsule dispensing lever 5 - Capsule chute 6 - Capsule chute cover 7 - Capsule release lever 8 - Device fastening tabs © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 32: Printed Board Functions And Indicator Lamps

    - Board power supply - Red LED - Boiler heating element triac - To boiler heating element - 120 V~ users - Relays K1÷K15 - C.P.U. board - Transformer fuses - Mains fuse Fig. 26 © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 33: Push-Button Board

    = MDB PUSH-BUTTON BOARD This board controls the alphanumeric display, the selec- tion buttons and the programming button (see Fig 28). It supports the coin mechanism connectors as well as the printer port. © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 34: Hydraulic System

    HYDRAULIC SYSTEM Water inlet solenoid valve Activation solenoid valve and piston purge Air-break Dispensing spouts Volumetric counter Boiler Vibration pump Instant drink mixer 9 bar brewing bypass valve 10 - Brewer unit © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 35: Programming Menu Summary

    Statistic N. 2 Previous function / Increase data unit (+1) Exit function / Cancel change Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item 0503 84554-00 © by NECTA VENDING SOLUTIONS SpA...
  • Page 36 Statistic N. 3 Previous function / Increase data unit (+1) Exit function / Cancel change Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 37 Display counters Previous function / Increase data unit (+1) Exit function / Cancel change Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item 0503 84554-00 © by NECTA VENDING SOLUTIONS SpA...
  • Page 38 Empty air-break Unit functions Previous function / Increase data unit (+1) Exit function / Cancel change Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 39 Exit function Statistics Previous function / Increase data unit (+1) Exit function / Cancel change Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item 0503 84554-00 © by NECTA VENDING SOLUTIONS SpA...
  • Page 40 Previous function / Increase data unit (+1) Exit function / Cancel change Machine installation Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item Reset failures 0503 84554-00 © by NECTA VENDING SOLUTIONS SpA...
  • Page 41 Previous function / Increase data unit (+1) Exit function / Cancel change Machine installation Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item Reset failures 0503 84554-00 © by NECTA VENDING SOLUTIONS SpA...
  • Page 42 Previous function / Increase data unit (+1) Exit function / Cancel change Machine installation Codice Macchina Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item Reset failures © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 43 Previous function / Increase data unit (+1) Exit function / Cancel change Machine installation Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item Reset failures 0503 84554-00 © by NECTA VENDING SOLUTIONS SpA...
  • Page 44 Previous function / Increase data unit (+1) Exit function / Cancel change Machine installation Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item Reset failures © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 45 Previous function / Increase data unit (+1) Exit function / Cancel change Machine installation Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item Reset failures 0503 84554-00 © by NECTA VENDING SOLUTIONS SpA...
  • Page 46 Previous function / Increase data unit (+1) Exit function / Cancel change Machine installation Next function / Decrease data unit (- 1) Confirm function / Confirm data unit Change data item Reset failures © by NECTA VENDING SOLUTIONS SpA 0503 84554-00...
  • Page 47: Wiring Diagram

    WASTE CONTAINER OVERFLOW SWIT TRANSFORMER OPEN DISP COMPT FLAP SWITCH TRANSFORMER 230 V 24 V EMPTY BOILER MICRO-SWITCH TX..DELAYED FUSE (X=COURRENT) KC1-.. COFFEE BOILER CUTOUT VARISTOR KS1-.. SAFETY CUTOUT VENT LIQUID CRYSTAL DISPLAY © by NECTA VENDING SOLUTIONS SpA 0503 83554-00...
  • Page 48 sx42200...
  • Page 49 LB 3202 120 V UL...
  • Page 50 © by NECTA VENDING SOLUTIONS SpA NOTE...
  • Page 51 The Manufacturer reserves the right to modify, without prior notice, the characteristics of the equipment described in this publication; and further declines to accept any responsibility for any inaccuracies contained in this publication which can be ascribed to printing and/or transcription errors. All instructions, drawings, tables and information contained in this publication are confidential and can neither be repro- duced completely or in part, nor be transmitted to third parties without the written permit of the Manufacturer, who has the sole ownership.

Table of Contents