U.S. Solid USS-FX00030 Manual

Ultrasonic cleaner dual frequency

Advertisement

Quick Links

Ultrasonic Cleaner
USS-FX00030 USS-FX00031 USS-FX00032
USS-FX00033 USS-FX00033 USS-FX00035
This manual shall be made available to all users of ultrasonic cleaners. To ensure
the best results and maximum durability of this U.S. SOLID LLC (hereafter U.S.
SOLID or The Company) product, read and follow all instructions carefully. Failure
to do so may lead to serious bodily injury and catastrophic damage to the cleaner,
supplies, or surrounding area. All safety suggestions must be followed closely, and
precautions must be taken to guarantee this ultrasonic cleaner is only used by
qualified personnel who have understood this guide.
Version 1.0 ©202406 U.S. SOLID LLC. All rights reserved.
For questions or concerns, email: service@ussolid.com
Dual Frequency
Manual NO. 9133

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the USS-FX00030 and is the answer not in the manual?

Questions and answers

Summary of Contents for U.S. Solid USS-FX00030

  • Page 1 USS-FX00033 USS-FX00033 USS-FX00035 This manual shall be made available to all users of ultrasonic cleaners. To ensure the best results and maximum durability of this U.S. SOLID LLC (hereafter U.S. SOLID or The Company) product, read and follow all instructions carefully. Failure to do so may lead to serious bodily injury and catastrophic damage to the cleaner, supplies, or surrounding area.
  • Page 2: Table Of Contents

    Contents I.Operating Principles ............1 II. Getting Started ..............2 III. Safety Instructions ............3 IV. Applications ..............7 V. Packing List ..............10 VI. Specifications ..............11 VI. Specifications ..............12 VII. Structure ...............13 VIII. Operation ..............16 For questions or concerns, email: service@ussolid.com...
  • Page 3: I.operating Principles

    I.Operating Principles Transducers at the bottom of the ultrasonic cleaner generate intense high-frequency sound through the solution in the tank inducing cavitation in liquid. As the cavitation bubbles collapse, high shearing energies work in all directions, attacking every surface and invading all recesses and openings to remove stains or debris on objects.
  • Page 4: Getting Started

    Changes in technology happen often and rapidly, which is why our team at U.S. SOLID reserves the right to modify the specifications and procedures for this ultrasonic cleaner immediately and without notice. The Company will not assume responsibility for equipment damage or malfunction due to improper operation, incorrect repairs, or use of unauthorized parts.
  • Page 5: Safety Instructions

    majeure (e.g., natural disasters such as hurricanes, floods, or earthquakes). This manual includes basic safety precautions, installation, operation, and maintenance instructions. III. Safety Instructions Before using your Ultrasonic Cleaner, please read and understand these safety precautions thoroughly. Failure to follow them may result in serious personal injury or property damage.
  • Page 6 are high voltages inside that could be dangerous.  Never immerse the cleaner or power cord in water or other liquid. DO NOT touch the unit if the machine has fallen into the water during operation. Remove the power plug from the socket first. ...
  • Page 7 irritation. Avoid contact with solutions and provide adequate ventilation.  Please cover the tank with the lid to reduce noise and take care to avoid the hot water and steam to prevent burning your skin while removing the lid.  Do NOT use the machine where the following conditions exist: A.
  • Page 8 be blocked.  Do NOT ever use mineral acids as these could damage the tank.  Do NOT run the machine CONTINUOUSLY for longer than 60 min. Running the cleaner for an extended time will cause temperature increases and damage the tank and transducers. ...
  • Page 9: Applications

    IV. Applications Ultrasonic cleaning machines can be applied in various fields such as 3D printing, electronics, electrical appliances, hardware, machinery, communications, biology, medical, eyewear, optics, jewelry, watches, chemicals, textiles, automotive, shipbuilding, aviation, industrial and mining, food inspection, biopharmaceuticals, laboratories, and universities.
  • Page 10 motors/rollers/fixing pieces on water pumps, LCD glass, magnetic core iron components, computer floppy disks, video tape components, iron ring components, magnetic heads, photo masks, etc.  Contaminants to be Removed: Fingerprints, powders, cutting oil, stamping shafts, iron filings, polishing materials, walnut powder, polishing wax, sticky residues, resins, dust, etc.
  • Page 11 cylinder parts, burners, compressors, spray guns, ultracentrifuges, faucets, filters, filter elements, etc.  Contaminants to be Removed: Cutting oil, iron filings, grease, polishing powder, fingerprints, etc. Medical Instruments  Workpieces, Products, and Materials to be Cleaned: Medical instruments, dentures, filter titanium rods, laboratory equipment, etc.
  • Page 12: Packing List

    Chemical Fiber  Workpieces, Products, and Materials to be Cleaned: Chemical fiber or artificial fiber nozzles, filter protectors, chemical fiber texture  Contaminants to be Removed: Chemical colloids, glue, other solid materials, dust, etc. V. Packing List Ultrasonic Cleaning Machine 1 unit Soundproof Cover 1 piece...
  • Page 13: Specifications

    VI. Specifications Model USS-FX30 USS-FX31 USS-FX32 Capacity 10 L Frequency 28/40 kHz 28/40 kHz 28/40 kHz Transducer 2 pcs 3 pcs 4 pcs Heating Power 200 W 300 W 300 W Ultrasonic Power 120 W 180 W 180 W Working Time 0-99 min 0-99 min 0-99 min...
  • Page 14: Specifications

    VI. Specifications Model USS-FX33 USS-FX34 USS-FX35 Capacity 15 L 22 L 30 L Frequency 28/40 kHz 28/40 kHz 28/40 kHz Transducer 6 pcs 8 pcs 10 pcs Heating Power 300 W 500 W 500 W Ultrasonic Power 360 W 480 W 600 W Working Time 0-99 min...
  • Page 15: Structure

    VII. Structure Temperature display window shows both the set temperature and the real-time temperature. Countdown display window. Temperature adjustment button.  Factory default setting for temperature is set to 50℃.  Adjusting the operational temperature  Pressing the "+" key increments the temperature by one degree For questions or concerns, email: service@ussolid.com...
  • Page 16  Holding "+" enables continuous temperature increase.  Pressing the "-" key decrements the temperature by one degree  Holding "-" enables continuous temperature decrease.  Pressing the button or key continuously to cycle the temperature setting between 0 and 99. Release the button when the desired temperature is displayed.
  • Page 17  Each press of the key "+" increases the time by one minute.  Holding down the key "+" continuously increases the time.  Each press of the key "-" decreases the time by one minute.  Holding down the key "-" continuously decreases the time. ...
  • Page 18: Operation

    Sweep, also known as Degas, functions in a frequency sweeping mode where the machine alternates continuously between 28kHz and 40kHz. This mode is suitable for objects requiring high cleanliness standards, challenging-to-clean items with blind holes (e.g., screw holes), high sterilization rates, and high-standard laboratory applications such as deaeration, defoaming, solubilization aid, alcohol extraction, emulsification, and extraction.
  • Page 19 Put items to be cleaned inside the basket and gently place the basket inside the tank. DO NOT PLACE THE ITEMS directly on the bottom of the tank. 3. Add solution according to the object to be cleaned. Ensure that the volume of the solution is over 2/3 when the heating is on.
  • Page 20 Set Working Time The default factory time setting is 5 minutes (factory preset time: 0500). You can also adjust the Ultrasonic Working Time on you own.  Each press of the key "+" increases the time by one minute.  Holding down the key "+" continuously increases the time.
  • Page 21 Set Working Temperature Factory default setting for temperature is set to 50℃. You can also adjust the operational temperature on you own.  Pressing the "+" key increments the temperature by one degree.  Holding "+" enables continuous temperature increase. ...
  • Page 22 If the set temperature is lower than the current temperature, the operation will be ineffective, and the heating function will not activate. The heating function must always be manually activated. Note that the ultrasonic function also produces energy, which may cause the liquid temperature to continue rising even after the set temperature is reached.
  • Page 23 Notes: 1. When the timer shows 0000, only the AUTO mode can be activated. Upon activation, the timer automatically resets to 1000 and starts counting down. When the timer shows 0000 again, the AUTO mode operation is completed. For other modes (SWEEP, 20kHz, 30kHz), the ultrasonic function cannot be activated unless the timer shows a value higher than 0000.
  • Page 24 Contact Information U.S. Solid 4560 Johnston Parkway, Cleveland, Ohio 44128 service@ussolid.com For questions or concerns, email: service@ussolid.com...

This manual is also suitable for:

Uss-fx00031Uss-fx00032Uss-fx00033Uss-fx00035

Table of Contents