SynQor MPC-3000 Series Operator's Manual

Military power conditioner
Table of Contents

Advertisement

Quick Links

M
P
C
ilitary
ower
onditioner
Operator's Guide
MPC-3000 Series
MPC-3000-2U
Made in USA
www.synqor.com
006-0006856 MPC-3000 Guide Rev J
|
SynQor 155 Swanson Road, Boxborough, MA 01719-1316 USA
|

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MPC-3000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SynQor MPC-3000 Series

  • Page 1 Operator’s Guide MPC-3000 Series MPC-3000-2U Made in USA www.synqor.com 006-0006856 MPC-3000 Guide Rev J SynQor 155 Swanson Road, Boxborough, MA 01719-1316 USA...
  • Page 2: Table Of Contents

    Section III Operation Set-Up ....................................18 Start-Up ..................................19 Shut-Down ..................................19 Power Cable Connections/Disconnections While Operating ..............20 Cooling System ................................21 Front Panel Indicators ..............................22 LEDs ..................................22 Audible alarm ..............................25 Operating Environment ............................26 006-0006856 MPC-3000 Operator Guide Rev J 2 of 48 04/01/2025 www.synqor.com...
  • Page 3 Remote On/Off Switch Connections ......................39 Digital Input/Output Control Signals ........................40 RS232 Serial Interface ...............................40 Ethernet Interface ...............................41 Section VI Maintenance Fans ....................................42 Cleaning..................................42 Section VII Trouble-Shooting Guide Fault Conditions ................................43 006-0006856 MPC-3000 Operator Guide Rev J 3 of 48 04/01/2025 www.synqor.com...
  • Page 4: Hazardous Voltages

    Warnings Hazardous Voltages The INPUT AND OUTPUT POWER connectors and cables of the SynQor MPC may have voltages that are unsafe. INJURY OR DEATH ON CONTACT may result. Appropriate safety precautions should be taken. All connections should be made in accordance with LOCAL ELECTRICAL CODES.
  • Page 5: Hazardous Energies

    MPC while the MPC is operating. No User Serviceable Parts The SynQor MPC has no user serviceable parts inside of it. DO NOT REMOVE the cover of the MPC or any of its connectors. Only factory trained personnel should perform repairs.
  • Page 6: General Product Information

    A communication/control port is available to permit monitoring and control by a host computer system. The MPC-3000 Series products can draw power from an AC input having a wide range of voltage and frequency levels, or from an optional 28 V nominal DC input. The AC input has priority over the DC input.
  • Page 7: Product Topology

    General Product Information Product Topology The SynQor MPC-3000 Series products use a true on-line double conversion topology that provides protection to the load from spikes, noise, surges, brownouts, blackouts, etc. in the input power sources. They also provide smoothing of load transients and nonlinear load profiles so that the input power sources are not subjected to these disturbances.
  • Page 8: Part Numbering Scheme

    MPC. There is a communication/control port that provides a digital interface to a host computer system. Part Numbering Scheme This table shows the part numbering scheme for the full line of SynQor MPC products: Base Model Model Number...
  • Page 9 Section II General Product Information The MPC-3000 Series of products provide up to 3000 VA and 2500 W of total output power (AC plus DC). • A 2U high, 49 lbs. rackmount unit. Various options can be specified according to the part numbering scheme shown in the table: •...
  • Page 10: Electrical Characteristics

    Air Flow 0.67(m /min) 23.7 CFM Four fans in system, above specs are for each fan separately. 100% rated power at 55C, 0% rated power at 70C. Derate linearly. 006-0006856 MPC-3000 Operator Guide Rev J 10 of 48 04/01/2025 www.synqor.com...
  • Page 11: 2U Mechanical Diagram

    [431.8] .750" [19.05] 18.700" [474.98] 22.22" [564.388] 9.750" [247.65] .750" [19.05] .750" [19.05] 1.50" [38.1] .313" [7.9502] UNIT .830" [21.082] MOUNTING 3.40" 1.750" HOLES [86.36] [44.45] .250" 8-32 [6.35] 006-0006856 MPC-3000 Operator Guide Rev J 11 of 48 04/01/2025 www.synqor.com...
  • Page 12: Mpc Efficiency

    Total Output Power that can be derived from the AC INPUT The total MPC output power (the AC OUTPUT power plus the optional DC OUTPUT power) for the MPC-3000 series is rated at 2500 W for an ambient temperature as high as 55 C (131 F).
  • Page 13 AC INPUT would be 2250 W at an AC INPUT voltage of 90 Vrms and an ambient temperature of 50 C (122 F). A higher output power than this would cause the MPC to switch over to its DC INPUT. 006-0006856 MPC-3000 Operator Guide Rev J 13 of 48 04/01/2025 www.synqor.com...
  • Page 14 15 seconds before the MPC will switch over to the DC INPUT. Also note that the MPC can drive it full rated power for a 2 second interval even if the AC INPUT voltage drops below 90 Vrms. 006-0006856 MPC-3000 Operator Guide Rev J 14 of 48 04/01/2025 www.synqor.com...
  • Page 15 250 W. Similarly, if the AC output is loaded to 2000 W and if either DC1A or DC1B is desired, it can only be loaded to 250 W. 006-0006856 MPC-3000 Operator Guide Rev J 15 of 48 04/01/2025 www.synqor.com...
  • Page 16: Power Cable Wiring Diagram

    Function Line Neutral 22-2 Ground DC1 OUTPUT Function +Vout1A +Vout1B VoutB Return 22-22 VoutA Return ITT-CANNON DC2 OUTPUT Function F, E, D +Vout A, B, C Vout Return 24-10 006-0006856 MPC-3000 Operator Guide Rev J 16 of 48 04/01/2025 www.synqor.com...
  • Page 17: Power Cable Wire Size

    While this is an issue for all of the power cables, it is particularly important for the DC Input, DC1 Output and DC2 Output cables because the current flowing through it is very high (as high as 130 A for the MPC-3000 Series) and the voltage across it is already relatively small (as low as 22 V).
  • Page 18: Operation

    Note: Be careful to not toggle the ON/OFF switch during the setup. Doing so could cause the MPC to turn on and present a hazardous voltage at its output. 006-0006856 MPC-3000 Operator Guide Rev J 18 of 48 04/01/2025 www.synqor.com...
  • Page 19: Start-Up

    • The MPC will disable its outputs and shut down. • It is not necessary to move the AC BREAKER on the rear panel of the MPC to the OFF position. 006-0006856 MPC-3000 Operator Guide Rev J 19 of 48 04/01/2025 www.synqor.com...
  • Page 20: Power Cable Connections/Disconnections While Operating

    MPC. However, the SynQor MPC is capable of having any of its input or output power cables connected at any time (if safely done), including when the MPC is turned on and delivering power to the load.
  • Page 21: Cooling System

    Operation Cooling System The SynQor MPC-3000 Series products are cooled by fans that draw air into the intake below the front panel and exhaust it out the four fan ports on the rear panel. Care should be taken to ensure there is no obstruction to this airflow, either at the front intake or the rear exhaust ports.
  • Page 22: Front Panel Indicators

    For example, it is conceivable that DCOUT1A and DCOUT1B load currents differ significantly, resulting in different reflected loads on the front panel, temperature, etc. 006-0006856 MPC-3000 Operator Guide Rev J 22 of 48 04/01/2025 www.synqor.com...
  • Page 23 MPC is On but the Output Voltage is Amber Out of Range MPC is Off and the Output Voltage is Within Range MPC is Off (Or the DC Output Option is not Installed) 006-0006856 MPC-3000 Operator Guide Rev J 23 of 48 04/01/2025 www.synqor.com...
  • Page 24 Green (Fans Running at 33%) Warm MPC Temperature Blinking Green (Fans Running at 67%) Elevated MPC Temperature Amber (Fans Running at 100%) Maximum MPC Temperature (Fans Running at 110%) 006-0006856 MPC-3000 Operator Guide Rev J 24 of 48 04/01/2025 www.synqor.com...
  • Page 25: Audible Alarm

    Indication Load Power is greater than or approaching 100% Rated Power Fault Appears on the AC Output Three MPC Must be Turned Off and Back On to Reset Fault 006-0006856 MPC-3000 Operator Guide Rev J 25 of 48 04/01/2025 www.synqor.com...
  • Page 26: Operating Environment

    Section III Operation Operating Environment The SynQor MPC-3000 Series is designed for the extreme environmental conditions of military and aerospace applications. All the electronic circuitry is contained in a sealed, weather-proof, shock-proof chamber constructed of die-cast aluminum. Only the redundant, water-proof cooling fans are exposed to the environment.
  • Page 27: Multiple Mpc Configurations

    MPC part numbers to be sure this is the case before ordering. Standard Paralleling -F Option With standard paralleling, up to three SynQor MPC units with identical model numbers can be combined in various ways to achieve: • Higher output power •...
  • Page 28: Expanded Paralleling -R Option

    See the following pages for details. These cables are unique to the –R paralleling option, and cannot be used with –F paralleling option units. Contact the SynQor factory for Single Phase systems larger than 3 MPC units, or for Split Phase and 3-Phase systems.
  • Page 29: Parallel Configurations Of The Ac Outputs: Up To Three Units

    Parallel Configurations of the AC OUTPUTS: Up to Three Units Multi-unit Configurations The chart below shows four possible ways the AC OUTPUTS of up to three SynQor MPC units can be connected together. Each configuration will be discussed in more detail in the following pages.
  • Page 30: Parallel Connection Of The Ac Outputs

    Parallel Connection of the AC OUTPUTS Two or three SynQor MPC units can have their AC OUTPUTS connected in parallel to deliver two or three time the output power and output current of a single unit. Units can also be connected to form 1+1 or 2+1 redundant systems.
  • Page 31: Three Mpc Units With Ac Outputs Paralleled

    Red Cable Section Minimum MPC AC Output Voltage Wire Size Wire Size 115 Vac #14 AWG (2.5 mm #10 AWG (6mm 230 Vac #16 AWG (1.5 mm #12 AWG (4mm 006-0006856 MPC-3000 Operator Guide Rev J 31 of 48 04/01/2025 www.synqor.com...
  • Page 32: Series Split Phase Connection Of Ac Outputs

    Phase”. When ordering, select the “F: Floating” option for MPC units configured in this manner. Contact the SynQor factory for N+1 redundant Split Phase systems. The wiring diagram for the AC OUTPUT cables and the CONFIGURATION cable for the Split Phase...
  • Page 33: 3-Phase Connection Of Ac Outputs

    Earth Ground (PEGND). When ordering, select the “F: Floating” option for MPC units configured in this manner. Contact the SynQor factory for N+1 redundant 3-Phase systems. Note: The three connectors of the SYN-9317 CONFIGURATION CABLE are labeled “Line 1”, “Line 2”...
  • Page 34: Parallel Configurations Of The Ac Outputs: Up To 32 Unit -R Option

    The figures below show the different system configurations that can be formed with “R” option units. Each system requires its own unique CONFIGURATION cable. Contact the SynQor factory to purchase system specific configuration cables. Note that configuration cables for two unit and three unit single phase systems are offered as standard products.
  • Page 35: Parallel Connection Of Dc Outputs

    • each MPC unit’s AC INPUT can be connected from one line of the AC source to another (i.e., L1 to L2, L2 to L3, or L3 to L1) 006-0006856 MPC-3000 Operator Guide Rev J 35 of 48 04/01/2025 www.synqor.com...
  • Page 36: Multi-Unit Ac Output On/Off Control - Standard Parallel (-F Option)

    (PEGND) in one spot. The size of the neutral-to-PEGND connecting conductor must be sized to match the largest combined AC output neutral conductor specified in the wiring diagrams above. 006-0006856 MPC-3000 Operator Guide Rev J 36 of 48 04/01/2025 www.synqor.com...
  • Page 37: Wiring Caution

    ALWAYS REMOVE INPUT POWER BEFORE MAKING MULTI-UNIT AC OUTPUT CONNECTIONS. ALL AC OUTPUT CABLE CONNECTORS MUST BE INSTALLED DURING OPERATION AS A DISCONNECTED CABLE CONNECTOR MAY HAVE EXPOSED VOLTAGE PRESENT FROM ANOTHER UNIT IN THE GROUP . 006-0006856 MPC-3000 Operator Guide Rev J 37 of 48 04/01/2025 www.synqor.com...
  • Page 38: Control Interface Details

    MPC and receive information regarding the status of the MPC. The Configuration male DB15 connector on the right is for a connection between one SynQor MPC and another when, for instance, they have their outputs connected in parallel and they therefore need to communicate and coordinate with each other.
  • Page 39: Internal User I/O Circuits

    Remote On/O Switch SHUTDOWN 1N4148 SPDT Momentary Input Pin (ON) OFF (ON) Note: A 2PDT or 3PDT switch may be substituted for single control of 2 or 3 MPC machines, respectively. 006-0006856 MPC-3000 Operator Guide Rev J 39 of 48 04/01/2025 www.synqor.com...
  • Page 40: Digital Input/Output Control Signals

    MPC’s operation. The port can be used from a standard terminal interface, or from a custom computer application. Terminal emulator should be set to send carriage returns with line feeds, and use local echo. 006-0006856 MPC-3000 Operator Guide Rev J 40 of 48 04/01/2025 www.synqor.com...
  • Page 41: Ethernet Interface

    MPC and a host computer by including a DHCP server internal to the MPC. For a detailed description of the Ethernet port and SNMP implementation see the SynQor website https://www.synqor.com/UPS/documents/UPS_Ethernet_SNMP_UG.pdf 006-0006856 MPC-3000 Operator Guide...
  • Page 42: Maintenance

    Cleaning should be done either with soap and water or with an Isopropyl alcohol and water mixture. A soft cloth should be used. Do not immerse the unit in water to clean it. 006-0006856 MPC-3000 Operator Guide Rev J 42 of 48 04/01/2025 www.synqor.com...
  • Page 43: Trouble-Shooting Guide

    Trouble-Shooting Guide Fault Conditions The SynQor MPC has no user-serviceable parts within it. If it has an internal malfunction only a factory trained personnel should attempt to repair it. There are, however, several external conditions that could cause the MPC to not operate as desired.
  • Page 44 MPC it is still running and providing an DC OUTPUT voltage. LED is RED • Some other source of voltage is connected to the DC OUTPUT and is powering it when the MPC is not 006-0006856 MPC-3000 Operator Guide Rev J 44 of 48 04/01/2025 www.synqor.com...
  • Page 45 The AC OUTPUT has therefore turned OFF. The DC output may 5 seconds) still be powered. • To reset, the MPC must be turned OFF and then ON. 006-0006856 MPC-3000 Operator Guide Rev J 45 of 48 04/01/2025 www.synqor.com...
  • Page 46 ▪ The MPC fails to start the load: The SynQor MPC is designed to try various start-up routines when it is first turned on to overcome the problem of surge currents with some loads. There are five such routines (or repetitions of a given routine) that are tried.
  • Page 47 The solution to this problem is to make sure that the cable has wires of sufficient diameter, or “gauge” for the length of the cable. The longer the cable, the bigger diameter the wire should have. See the section “Power Cable Wire Size” for recommended cable wire sizes. 006-0006856 MPC-3000 Operator Guide Rev J 47 of 48 04/01/2025 www.synqor.com...
  • Page 48 Operator’s Guide MPC-3000 Series 006-0006856 04/01/2025 Rev J Made in USA www.synqor.com 006-0006856 MPC-3000 Guide Rev J SynQor 155 Swanson Road, Boxborough, MA 01719-1316 USA...

This manual is also suitable for:

Mpc-3000-2u

Table of Contents