Page 1
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) Content 1. 10HP Floor Standing Unit ......................2 1.1 Inverter 10HP Floor Standing Unit ................2 1.1.1 Appearance and Features ................... 2 1.1.2 Operating Conditions ................... 2 1.1.3 Specifications ......................
Page 2
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) 1. 10HP Floor Standing Unit 1.1 Inverter 10HP Floor Standing Unit 1.1.1 Appearance and Features Features • The inverter design of ODU ensures higher energy efficiency.
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) Note: If the above operating conditions cannot be met, the safety protection function may be triggered and the air conditioner may malfunction. When the unit operates in "Cool" mode in a relatively humid environment (relative humidity higher than 80%), condensation may occur on the surface of the IDU and water may drip.
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) temperature of 27°C/19°C and the outdoor dry bulb/wet bulb temperature of 35°C/24°C; the heating capacity of the air conditioner is measured under the indoor dry bulb/wet bulb temperature of 20°C/15°C and the outdoor dry bulb/wet bulb temperature of 7°C/6°C.
Page 5
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) 1. Terminal block functions of ODU ODU monitor Digital IDU centralized IDU and ODU multimeter controller communication Use a three-core shielded wire for communication line Note: The digital power meter and IDU centralized controller in the dotted wire frame are optional accessories.
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) 3. Electrical connection diagram Outdoor Power Supply On/Off switch Fuse ODU monitor power supply ODU monitor (optional) Power supply of IDU centralized controller IDU centralized controller (optional)
Page 7
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) 1.1.5 Names and External Dimensions of All Parts Air outlet Vertical louver Adjust horizontal Horizontal louver air flow (automatic) Adjust vertical air flow (manual) Remote control...
Page 8
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) ODU dimensions 1.1.6 Installation Instructions 1.1.6.1 IDU Installation 1. Selecting an installation site for IDU 1) Sufficient space for installation and maintenance. 2) The ceiling is level, and the structure is strong enough to support the weight of IDU;...
Page 9
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) 1.1.6.2 ODU Installation 1. Selecting an installation site for ODU 1) Sufficient space for installation and maintenance. 2) Unobstructed air flows in/out of the unit, and there is no strong breeze; the site should be dry and well-ventilated.
Page 10
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) 2) Do not hold the air outlet grille on the casing; otherwise, it will be deformed. Do not touch the air blades with your hands or other objects.
Page 11
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) Φ9.5 0.057 kg 1.1.7 Pipe Connection Methods 1. Connect the IDU as shown in the following figure 2. Allowable length and level difference for refrigerant pipe (liquid side pipes only)
Page 12
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive One Floor Standing Unit) Network matching wires...
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) 1. 10HP One-Driven-Two Unit 1.1 Inverter 10HP One-Driven-Two Unit 1.1.1 Appearance 1.1.2 Features Applicable to shops, restaurants, meeting rooms, etc. High energy efficiency: The ODU adopts the DC inverter compressor and the VRF core technology for highly adjustable air conditioning functions.
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) 1.1.3 Operating Conditions To maintain good performance, please operate the air conditioner under the following temperature conditions. Operating Mode Cool Heat Temperature Room temperature 17°C to 32°C 0°C to 30°C...
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) Protection against electric shock Class I Control mode Remote controller or key controller T5A 250VAC Main board fuse specification T10A 250VAC Notes: 1. The cooling capacity of the air conditioner is measured under the indoor dry bulb/wet bulb temperature of 27°C/19°C and the outdoor dry bulb/wet bulb temperature of 35°C/24°C;...
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) Air inlet Air inlet (both the left side and back) Air outlet (Hot air is blown out during cooling operation and cold air is blown out during heating...
Page 18
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) b. PQE is connected to a weak-current signal cable. Do not connect it to a strong-current cable. c. All the terminal blocks must be reliably fixed, and the grounding cables must be grounded as required.
Page 19
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) > 600 (Wall or obstacle) > 300 Air inlet surface Maintenance > 300 cable and pipeline surface Air inlet surface > 600 Fixed with a bolt > 3000 Air outlet surface >...
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) 1) Connect the IDU as shown in the following figure 2) Allowable length and level difference for refrigerant pipe (liquid pipes only) MOUB-96HD1N1-R Pipe length Level difference...
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) Equivalent length to the closest branch pipe of the connection Branch joint Equivalent length of the longest pipe of the IDU Notes: 1. Use the special-purpose branch joint provided by Midea.
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) Notes: 1. The cooling capacity of the air conditioner is measured under the indoor dry bulb/wet bulb temperature of 27°C/19°C and the outdoor dry bulb/wet bulb temperature of 35°C/24°C; the heating capacity of the air conditioner is measured under the indoor dry bulb/wet bulb temperature of 20°C/15°C and the outdoor dry bulb/wet bulb temperature of 7°C/6°C.
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) direction of the drain pan; otherwise, the float switch may malfunction and cause water leakages. 3. Electrical connection 1) Power supply specifications Refer to the following table for the power cable specifications. A capacity too small will cause wire overheating, and lead to accidents when the unit burns and becomes damaged.
Page 24
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) a. Use only shielded wires for the control wiring. Any other type of wires may produce a signal interference that will cause the units to malfunction. b. All the shielded wiring in the network are interconnected, and will eventually connect to earth at the same point "...
Page 25
MCAC-UTSM-201911 Midea 10HP DC Inverter Split Air Conditioner (One Drive Two Q4 Unit) 4. Space required for installation and maintenance Refrigerant Connect to pipe connector water pipe outlet (liquid side) Refrigerant pipe connector (gas side) Panel Ceiling Air outlet Air inlet...
Page 26
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 Content 1. 10HP Duct Unit ............................ 2 1.1 Inverter 10HP Duct Unit ......................2 1.1.1 Appearance and Features ....................2 1.1.2 Operating Conditions ......................2 1.1.3 Specifications ........................3 1.1.4 Electrical Connection ......................
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 1. 10HP Duct Unit 1.1 Inverter 10HP Duct Unit 1.1.1 Appearance and Features Features • The inverter design of ODU ensures higher energy efficiency. • The ODU inverter module adopts the refrigerant cooling technology to realize fast heat dissipation and improve stability and reliability.
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 may drip. In this case, turn the air guide to the maximum air outlet position and set the fan speed to "High". 1.1.3 Specifications IDU model MHA-96HWAN1...
Page 29
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 dry bulb/wet bulb temperature of 7°C/6°C. The actual cooling/heating capacity will vary with the indoor and outdoor ambient temperature and relative humidity. 2. The noise of the air conditioner is measured in the semi-anechoic noise laboratory according to the Chinese national standard.
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 specification T10A 250VAC Notes: 1. The cooling capacity of the air conditioner is measured under the indoor dry bulb/wet bulb temperature of 27°C/19°C and the outdoor dry bulb/wet bulb temperature of 35°C/24°C; the heating capacity of the air conditioner is measured under the indoor dry bulb/wet bulb temperature of 20°C/15°C and the outdoor...
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 1. Power supply specifications Input IDU and ODU Power capacity Grounding connection line cable Model Power supply main cable size dimension switch/fuse (weak-current signal cable) Single-phase220V MHA-96HWAN1 20/10 3×1.5...
Page 32
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 3. Electrical connection diagram Wired controller (optional) Power supply 220V 50Hz Power supply of IDU centralized controller IDU centralized controller (optional) Digital multimeter power supply Digital multimeter...
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 1.1.5 Names and Dimensions of All Parts Electric control box Sound attenuated enclosure (not provided with the unit, optional on the site) Air outlet pipe Drainage (not provided with the unit, optional on the site)
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 IDU dimensions Air outlet 3 4 5 Gas side connector of refrigerant pipe 35.5 Liquid side connector of 1 5 0 refrigerant pipe 1.1.6 Installation Instructions 1.1.1.1 IDU Installation 1.
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 2) Unobstructed air flows in/out of the unit; there is no strong breeze. 3) The site should be dry and well-ventilated. 4) The supporting surface should be flat and can bear the weight of the unit. The ODU should be able to be installed horizontally without increasing the vibration and noise.
Page 36
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 unit with a hoist cable. 2) Do not hold the air outlet grille on the casing; otherwise, it will be deformed. Do not touch the air blades with your hands or other objects.
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 No refrigerant needs to be charged when the length of the one-way pipe is less than 5 m (the unit has been charged with refrigerant before delivery).
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 3) Make sure to keep the connecting pipes dry during installation so that no water will enter the pipeline system. 4) Connecting copper pipes must be wrapped with insulation materials (thicker than 9 mm).
Page 39
Midea 10HP DC Inverter Split Air Conditioner (One Drive One Duct Unit) MCAC-UTSM-201911 Chassis waterproof Used for ODU cover Seal ring Used with water outlet pipe Used for ODU Drain pipe connector Connecting to the drain pipe Used for ODU...
Need help?
Do you have a question about the MFA-96HWAN1-R and is the answer not in the manual?
Questions and answers