Summary of Contents for United Appliances UAWH09-AD3D1
Page 1
Owner's Manual Original Instructions Split Air Conditioner Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local agent or visit www.unitedappliances.com for the electronic version. NOTE:Actual product may be different from graphics, please refer to actual products.
CONTENTS Safety precautions Parts name Operation and introduction of remote controller WiFi remote controller app Clean and maintenance Checked items before maintenance Installation notice Installation of indoor unit Test and operation Configuration of connection pipe Manufacturer’s Limited Warranty...
Page 3
THIS MANUAL IS INTENDED FOR THE FOLLOWING MODELS: UAWH09-AD3D1 | UAWH09-DD3D1 UAWH12-AD3D1 | UAWH12-DD3D1 UAWH18-DD3D1 | UAWH24-DD3D1 UAWH30-DD3D1 | UAWH36-DD3D1...
Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION property. Indicates important but not hazard-related information, used to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons.
Page 5
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 6
This equipment complies with FCC’s and IC’s RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
Safety precautions WARNING Installation Installation or maintenance should comply with nation- must be performed by qua - al electric safety regula- ified professionals. tions. The appliance shall be in- Air Conditioner should be stalled in accordance with properly grounded. Inco - rect grounding may cause national wiring regulations.
Page 8
Safety precautions CAUTION Installation achable after finishing in- formed in accordance with stallation. the requirement of NEC and CEC by authorized For the air conditioner personnel only. with-out plug, a circuit Instructions for installation breaker must be installed and use of this product are in the line.
Page 9
Safety precautions WARNING Operation and Maintenance tioner to multi-purpose This appliance can be used socket. Otherwise, it may by children aged from 8 cause fire hazard. years and above and per- Do disconnect power sup- sons with reduced physi- ly when cleaning air cal, sensory or mental ca- condit ioner.
Safety precautions CAUTION Operation and Maintenance frequently. Do not spill water on the re- Air conditioner gives off mote controller, otherwise burning smell. the remote controller may Indoor unit is leaking. be broken. Do not use fire or hair dry- er to dry the filter to avoid deformation or fire hazard.
Parts name Indoor Unit If remote controller is lost or damaged, please use aux. button to turn on or turn off the air conditioner. The operation in details is as below: As shown in the figure, open panel and press aux. button to turn off the air conditioner. When the air conditioner is turned on, it will operate under auto mode.
Child lock Quiet WiFi remote controller app UA United Appliances smart air conditioner has a WiFi remote control system. It can be controlled by a smartphone with 2.4G WiFi, 2G, 3G, 4G network. Scan the following QR code with your cell phone camera to download the user´s...
Page 13
Introduction for buttons on When selecting heat mode, the air conditioner remote controller operates under heat mode. Press "+" or "-" button to adjust set temperature. Press "FAN" NOTE button to adjust fan speed. Press "SWING" button This is a general use remote controller . It could be to adjust fan blowing angle.
Page 14
temperature “88” will display the corresponding set temperature 1 ( ). Holding "+" or "-" button, 2s temperature of last setting sleep curve and blink later, set temperature on remote controller will (The first entering will display according to the change quickly.
Page 15
OFF setting. After each pressing "+" or "-" button 8℃-heating. When 8℃-heating is started up, " " TIMER OFF setting will increase or decrease 1min. will be shown on remote controller, and the air Hold "+" or "-" button, 2s later, the time will change conditioner keep the heating status at 8℃.
ditioner may blow cool or warm air, which is a NOTE normal phenomenon. During cleaning process, Press this button continuously for more than 2s, the please make sure the room is well ventilated to main unit will swing back and forth from up to down, avoid affecting the comfort.
Night mode Under cooling or heating mode, when turning on sleep mode and turn to low speed or quiet notch, the outdoor unit would enter into night mode. NOTE ● When you feel that the cooling and heating effect is poor, please press "FAN"...
Clean and maintenance WARNING ■ The filter should be cleaned every three months . If there is much dust in the operation environme- WARNING nt, clean frequency can be increased. ■ Turn off the air conditioner and disconnect the ■ After removing the filter, do not touch fins to power before cleaning the air conditioner to avoid injury.
Checked items before maintenance Phenomenon Solution Check items Whether there’s od- General phenomenon analysis Eliminate the odour Odours are our source, such as source. Clean the Please check below items before asking for furniture and cigare- emitted filter. maintenance. If the malfunction still can’t be tte, etc.
Installation notice WARNING sure that the unit is running in cooling mode. Then, fully close the valve at high pressure side (liquid valve). About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant recovery should not exceed 1 minute.
Selection of installation location Requirements for electric connection Basic requirement 7.If the supply cord is damaged, it must be repla- Installing the unit in the following places may cau- ced by the manufacturer, its service agent or se malfunction. If it is unavoidable, please consu- similarly qualified persons in order to avoid a lt the local dealer: hazard .
Installation of indoor unit Indoor outdoor Pay attention to dust prevention Step 1: sures when opening the hole. Choose installation location 5-10 Recommend the installation location to the client and then confirm it with the client. Step 2: Step 4: Install wall-mounting frame Outlet pipe 1.Hang the wall-mounting frame on the wall;...
Page 23
drain hose Hex nut diameter Tightening torque (N m) 15~20 30~40 45~55 insulating pipe NOTE 70~75 Add insulating pipe in the indoor drain hose in order Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it Step 7: with tape Connect wire of indoor unit...
Page 24
drain hose connection pipe 3. Remove the wire clip; connect the power conn- band ection wire to the wiring terminal according to the color; tighten the screw and then fix the po- wer connection wire with wire clip. indoor power cord Bind them evenly.
Test and operation Check after installation ● Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been The unit may drop, shake or installed firmly? emit noise. It may cause insufficient Have you done the refri- cooling(heating) capacity.
Configuration of connection pipe Additional refrigerant charging amount for R22, R407C, R410A and R134a Standard length of connection pipe: 5m, 7.5m, Min. length of connection pipe is 3m. Max. length of connection pipe is shown as below. Max. length of connection pipe Max.
B: Remove the burrs smooth surface Remove the burrs with shaper and prevent the ● burrs from getting into the pipe. improper expanding pipe shaper leaning damaged crack uneven surface thickness downwards the length is equal Working temperature range C: Put on suitable insulating pipe For some models: Indoor side Outdoor side...
MANUFACTURER’S LIMITED WARRANTY WARRANTOR. This Limited Warranty is offered by Dragon Trade International Corp , 1205 Highland Avenue, National City, California 91950, (“Manufacturer”) on the Products described below. PRODUCT. This Limited Warranty applies to the following products, residential and commercial air conditioner units manufactured by Manufacturer, collectively (“Product”). WHO MAY USE THIS WARRANTY .
Page 29
AUTHORIZED TO CHANGE THIS LIMITED WARRANTY IN ANY RESPECT OR CREATE ANY OTHER OBLIGATION OR LIABILITY FOR MANUFACTURER IN CONNECTION WITH THE PRODUCT OR ANY UNITED APPLIANCES EQUIPMENT. 5.07 UNDER NO CIRCUMSTANCES SHALL MANUFACTURER BE LIABLE FOR ANY INDIRECT, INCIDENTAL, SPECIAL, PUNITIVE OR CONSEQUENTIAL DAMAGES, INCLUDING,...
Page 30
5.10 In the event of a Product failure, the Product should be de-energized, but otherwise should remain as-is, where-is until inspected by an authorized technician, unless there is a life/safety threat or the likelihood of resultant physical damage to other property, in which case all appropriate safety precautions should be taken by qualified persons.
Page 31
COMPETENT JURISDICTION CONSUMER AND MANUFACTURER AGREE THAT ANY DISPUTE, CLAIM OR CONTROVERSY ARISING OUT OF THIS AGREEMENT OR THE USE OF THE PRODUCT, INCLUDING ISSUES OF ARBITRABILITY, SHALL, ("DISPUTE"), AT THE OPTION OF EITHER PARTY, BE RESOLVED BY BINDING ARBITRATION BEFORE A SINGLE NEUTRAL ARBITRATOR ADMINISTERED BY JUDICIAL ARBITRATION AND MEDIATION SERVICES ("JAMS") UNDER ITS APPLICABLE ARBITRATION RULES IN EFFECT AT THE TIME THE DISPUTE ARISES.
Page 32
8.03 Commencing the Arbitration. All claims in arbitration are subject to the same statues of limitations that would apply in court under applicable law. The Party bringing the claim must demand arbitration in writing and deliver the written demand by hand or first-class mail to the other party within the applicable statute of limitations period.
Page 33
RETURN AND EXCHANGE If you have any issues with your product or not entirely satisfied, please visit https://unitedappliances.com/us/returns-exchange/ or scan the QR code for all the steps.
Page 34
Imported by Dragon Trade International Corp. 614 5th Ave. Ste D, San Diego CA 92101-6964 Customer service: (800) 691-2050 unitedappliances.com...
Need help?
Do you have a question about the UAWH09-AD3D1 and is the answer not in the manual?
Questions and answers