Portable altimeter and vsi combo instrument with analog and digital representation, support for metric operation, with settable altitude alarm

Advertisement

Quick Links

Portable Altimeter and VSI Combo instrument with analog and digital
representation, support for Metric operation, with settable altitude
alarm. Dial and altitude change to red when altitude exceeded. Also
RADIANT Technology's GEN2 instruments include SafeAlt, which is a
complete altimeter and VSI combo, along with a settable alarm.
General technical specifications:
Sunlight readable.
Dimmable for night operation.
Battery Life of 5+ hours; USB rechargeable.
Configurable altitude alarm changes the dial
to red and produces aural alarm.
Altimeter range: 0 to 20K feet (will not show
below zero altitudes). (Metric format also
supported.)
VSI range: +/- 1999 feet per minute. (Metric format also supported.)
Altimeter display type: analog dual needle representation
supplemented by digital value. Digital value may be either feet or
meters, user selectable.
VSI display type: analog single needle supplemented by digital value.
Feet or meters, user selectable.
Kollsman window: digital, either inches mercury or KPa mercury. (EG:
29.92 or 1013)
SafeAlt
has aural alarm which may be muted.
Technical Specifications / Operation
Last updated March 13, 2025
TM
SafeAlt

Advertisement

loading
Need help?

Need help?

Do you have a question about the SafeAlt and is the answer not in the manual?

Questions and answers

Summary of Contents for Radiant SafeAlt

  • Page 1 Dial and altitude change to red when altitude exceeded. Also has aural alarm which may be muted. Technical Specifications / Operation Last updated March 13, 2025 RADIANT Technology’s GEN2 instruments include SafeAlt, which is a complete altimeter and VSI combo, along with a settable alarm. General technical specifications: •...
  • Page 2 Operation: Charge for 4 hours before use. • • Turn the unit on. The brightness may be dimmed to night mode by pressing either • button for more than 5 seconds. To adjust for local pressure, touch the UP or DOWN buttons briefly. •...
  • Page 3 • Press either button to mute the aural alarm. It will remain muted until the unit is power cycled. When the display starts to dim or cutout, it’s time to charge the • battery, or attach a USB power source. A red LED is visible through a small hole, very close to the USB port.
  • Page 4 DISCLAIMERS: Products from Radiant Technology are not designed to be used in applications where their failure would endanger safe flight or human life in any way. They are intended solely for use in VFR conditions. They are not certified to meet any Technical Standard Order and are not produced under a Parts Manufacturing Authority (TSO / PMA).