Liros GRAIN-WATCH GW200 Installation & User Manual

With hand instrument

Advertisement

Quick Links

®
GRAIN-WATCH SYSTEMS
with Hand Instrument
with Hand Instrument
INSTALLATION/USER MANUAL
AB LIROS ELECTRONIC
A719A01 GW200manualENG071115.cdr

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GRAIN-WATCH GW200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Liros GRAIN-WATCH GW200

  • Page 1 ® GRAIN-WATCH SYSTEMS with Hand Instrument with Hand Instrument INSTALLATION/USER MANUAL AB LIROS ELECTRONIC A719A01 GW200manualENG071115.cdr...
  • Page 2: Table Of Contents

    2.2 GW200 for use with sensor spears GWSS2000 2.3 ATEX 3 Operation and maintenance 3.1 Normal use 3.2 Batteries 3.3 Troubleshooting 4. Technical data AB Liros Electronic, Box 9124, S-200 39 Malmö, SWEDEN Tel: +46 40 14 20 80, Fax: +46 40 94 73 88 www.liros.se, mail@liros.se...
  • Page 3: Overview

    When the GW200 is used for silo distributed throughout the entire length of storages, it usually interfaces to the silo. GWSL1000/2000 sensorlines which are suspended in the ceiling of the silo and A719A01 GW200manualENG071115.cdr AB LIROS ELECTRONIC...
  • Page 4: Gw200 And Sensor Spears For Flat Storage

    32. grain is filled and emptied, short sensor- The maximum total cable length lines could also be used in flat storage between the spears and to the instead of sensor-spears. acquisition point, not including the A719A01 GW200manualENG071115.cdr AB LIROS ELECTRONIC...
  • Page 5: Electrical Installation

    The junction box should be placed on top of the silo, as close to the sensor-lines connected to it as possible. Sensor-Line Sensor-Line Sensor-Line JB-05 Signal (+) Jack Plug 0V (-) Junction Box JB-05 Junction Box JB-05 Jack plug at acquisition point Sensor Lines A719A01 GW200manualENG071115.cdr AB LIROS ELECTRONIC...
  • Page 6: Gw200 For Use With Sensor Spears Gwss2000

    ATEX approved. GWBA01 +5VNET 0V(-) to sensor-lines or junction boxes 3,5mm jack plug at DNET Signal (+) to sensor-lines or junction boxes acquisition point See also the installation manual for the GWBA01 for more details. A719A01 GW200manualENG071115.cdr AB LIROS ELECTRONIC...
  • Page 7: Operation And Maintenance

    A719A01 GW200manualENG071115.cdr AB LIROS ELECTRONIC...
  • Page 8: Batteries

    In case you need to contact LIROS regarding troubleshooting or service, make sure to have the version number of the internal software available - See 3.1 above. 4. TECHNICAL DATA Item...