0101-8240-2A Technical Manual for ® Simba 2 Power Supply For Serial Number 371 and above April 1997 Temescal, a division of Ferrotec (USA) Corporation 4569-C Las Positas Road, Livermore, CA 94551 Tel: 1-800-522-1215; Fax: 925-449-4096...
Page 2
Revision History 0101-8240 REV. VERSION/CHANGE DESCRIPTION APPLICATION/REASON FOR CHANGE DATE APPROVED Applies to SN 200 and above 9/26/91 Made changes throughout manual. Improved and corrected installation 7/21/93 Added Figure 2-14. instructions. No Engineering changes. Revised instructions for connecting to To cover hardware features added since 5/3/96 system EMO/EPO circuit (pages 2-14 Rev.
Gun Interface Front Panel 3-18 Front-Edge Components on Gun Control and Position PCBs 3-19 Initial Operation 3-22 Setting the Longitudinal Coil Current Limits 3-30 Setting the Filament Current Bias Level 3-33 Setting Up Current Ranges 3-35 0101-8240-2A Simba 2 Power Supply...
Page 4
Gun Interface Drawings 7-18 HV/Gun Control Unit Drawings 7-28 PARTS LISTS Parts Lists Listed by Page Number Power Module Parts Lists Gun Interface Parts Lists 8-17 HV/Gun Control Unit Parts Lists 8-29 Spare Parts Kits 8-35 Simba 2 Power Supply 0101-8240-2A...
Page 5
RF energy may be radiated outside the equipment. Monitor the equipment to assure that external RF radiation is below the levels prescribed by any and all applicable safety codes. 0101-8240-2A Simba 2 Power Supply...
Page 6
18(d) and 28 of the 1980 Regulations, as amended; and 2. The employer’s responsibility to set up suitable systems to safeguard the health and safety of employees, according to the Health & Safety at Work etc. Act (1974). Simba 2 Power Supply 0101-8240-2A...
Defective equipment shall not be used. Parts that are broken, missing, plainly worn, distorted, or contaminated, shall be replaced immediately. Should such repair or replacement become necessary, a telephone or written request for service should be made to Temescal, Livermore, CA, a division of Ferrotec (USA) Corp.
Use isopropyl alcohol (IPA), instead. Dispose of all IPA-exposed lint-free paper/cloth into a fireproof container, while ensuring all proper safety procedures and precautions are being followed. Simba 2 Power Supply 0101-8240-2A...