Approved Copy TABLE OF CONTENTS INTRODUCTION STANDARD FEATURES DISCHARGE OPTION IMPORTANT NOTICE SAFEGUARDS GROUNDING/EARTHING FUSE TYPE/REPLACEMENT OPERATION Self-test Charging Applications Three Stage Charging Methodology LCD Indications LED Indications Priority Battery Functions DDM (DIAGNOSTIC/DISCHARGE MODULE) TO OPERATE THE POWERCHARGER WITH DDM ® “AUTOCAL” Feature OPERATION AS DC CAMERA SUPPLY FROM MAINS POWER LOSS MEMORY MODE FCC NOTICE WARRANTY...
Approved Copy INTRODUCTION DISCHARGE AND LCD OPTIONS The Diagnostic/Discharge module (DDM) features automatic This Anton/Bauer InterActive 2000™ PowerCharger represents ® ® ® calibration of DIGITAL batteries. This also allows periodic diagnostic over 25 years of Anton/Bauer technology and experience in a totally testing of any Logic Series battery. This optional module is a new portable power system. The technology advancements of ® standard feature of the DUAL 2702 and QUAD 2702. See the “DDM” this new combination, charger/camera power supply, delivers the section in this manual for further details. features and performance of several essential power products in one economical package. An LCD is also available, but is a standard feature on DUAL 2702 and QUAD 2702. Each LCD will display the status of each battery, as well Fully compatible with all current and future Anton/Bauer Logic Series ® as important PowerCharger operating indications. See the “LCD Gold Mount batteries, the InterActive 2000 system is a totally new ® ® ® Indication” section in this manual for further details. modular platform. PowerChargers deliver all the advancements and ®...
Approved Copy OPERATION CONTINUED GROUNDING/EARTHING IMPORTANT WARNING: THIS APPARATUS MUST APPLICATIONS BE EARTHED. All PowerCharger models will charge any combination of Anton/Bauer ® Logic Series Gold Mount batteries including models: ProPac 14, ® ® To ensure safe operation, the three pin plug supplied must be inserted Trimpac 14, Digital ProPac 14, Digital Trimpac 14, InterActive 2000 ® ® ® ® only into a standard three-pin power point which is effectively grounded HyTRON , and DIONIC batteries.
Approved Copy OPERATION CONTINUED THREE STAGE CHARGING METHODOLOGY will deliver a three stage charge routine to each battery. In general, the PowerCharger ® 1. STAGE ONE will deliver a high rate charge matched to the capabilities of the battery (typically a one or two hour rate, depending on battery type and charger power module rating). During this stage, six separate cutoff methods are in operation, simultaneously, ensuring the fastest, safest charge for that battery. Stage One is indicated by the LCD displaying “Charging (Primary)”.: TCO - Temperature cutoff which stops the Stage one charge precisely when a temperature indicative of full charge is reached; Dt/dT - A microprocessor based algorithm which measures a rise in temperature over a specific time, very accurately indicating full charge. This method is also the recommended method for charging Ni-MH technology; ∆V - A method to determine the end of stage one charging by identifying a characteristic “reverse slope” of a Ni-Cd cell. Since this characteristic can be disguised by the age, temperature and the number of the cells in a battery, it can never be employed alone; CCO - This method requires the identification of the particular battery size (capacity) and chemistry, an exclusive Anton/Bauer Logic ® Series feature. The charger determines the maximum charge time for the particular battery and uses this information to ensure that overcharge conditions are avoided. FUL - This determination is made when a fully charged DIGITAL battery is returned to a PowerCharger within specified parameters of time, temperature, and battery voltage. The DIGITAL battery communicates its fully charged condition and the charger confirms the parameters and immediately indicates a fully charged condition, without additional verification. TEMPERATURE COMPENSATED VCO – For HyTRON series of batteries. Similar to a VCO, however, only operates within certain ™...
Approved Copy OPERATION CONTINUED LCD INDICATIONS Each PowerCharger’s liquid crystal display (LCD) will display the status of each battery, as well as, important PowerCharger operating ® ® indications. The following information explains the indications which appear in the LCD. The levels of the LCD display on each PowerCharger can be obtained by pressing the DISPLAY, or in some cases TEST, button on the ® PowerCharger front panel. ® The Main Display shows the general status of each battery mounted to the PowerCharger . This display is immediately returned to following ® self test and after viewing any other screen. Both the two position (above) and four position Main Displays will show a series of dashes when a battery has not been mounted to the PowerCharger ® The Main Display of the PowerCharger will show the abbreviated ®...
Approved Copy OPERATION CONTINUED LED INDICATIONS Each charge position of a PowerCharger has a pair of LEDs (one red, one green) which indicate the status of the battery attached to that ® position. The following table identifies all of the PowerCharger LED indications and their meaning: ® LED INDICATION MEANING Alternating Indicates that the PowerCharger is evaluating the battery and/or communicating with ®...
Approved Copy DDM (DIAGNOSTIC/DISCHARGE MODULE) (standard on Model DUAL 2702 and QUAD 2702) The DDM is a modular addition which will upgrade any InterActive 2000 ® PowerCharger to a complete battery management system. A standard 3. Hold the TEST button as the unit beeps 3 times. Release the button ® feature with the DUAL 2702 and QUAD 2702, the DDM can be easily added and the unit will indicate that the test mode has been selected. to any model PowerCharger , at any time. With this module installed, This Standard test will charge-discharge-charge the battery. Testing ®...
Approved Copy “AUTOCAL” Feature During camera operation, with batteries on the PowerCharger , the unit ® will indicate a flashing GREEN LED for any battery position which is When a DDM is installed in the PowerCharger , a special InterActive ® ® more than 50% charged. Batteries less the 50% charged will have no mode is automatically enabled for DIGITAL batteries placed on the indication. PowerCharger at any time. The PowerCharger will interrogate the ®...
Approved Copy FCC NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This equipment has been approved by one or more agenies. All changes and/or modifications not expressly approved by Anton Bauer, Inc. could void the users’ warranty and authority to operate this equipment. There are no serviceable parts in this equipment.
Approved Copy LIMITED WARRANTY This one (1) year limited warranty for the product specified in this be brought by any person under this Warranty, such action shall be document (“Product”) is given by Anton/Bauer, Inc. (“Anton/Bauer”), brought only in the United States District Court for the District of 14 Progress Drive, Shelton, Connecticut 06484. If you (the purchaser Connecticut, or in any Superior Court in Fairfield County, Connecticut, of the Product from Anton/Bauer, or the person for whom the Product USA. Some states do not allow limitations on how long a warranty was purchased, if it was a gift) have any questions regarding Product lasts, so the time period limitation herein may not apply to you. applications, Product specification, or to obtain warranty service on Some states do not allow the exclusion or limitation of incidental or this or any Anton/Bauer product, contact the company at the address consequential damages, so the above limitation or exclusion may not above. apply to you. This warranty gives you specific legal rights and you may have other legal rights which may vary from state to state. THIS PRODUCT MUST BE REGISTERED WITH ANTON/BAUER WITHIN 30 DAYS OF PURCHASE TO ASSURE WARRANTY Use of unauthorized equipment in conjunction with Anton/Bauer COVERAGE. TO REGISTER YOU MAY EITHER: products constitutes misuse under our warranties and may limit or void those warranties. Anton/Bauer does not authorize, condone, 1. MAIL WARRANTY REGISTRATION CARD or recommend, or otherwise assume any liability or responsibility resulting 2. REGISTER ON LINE AT www.antonbauer.com from the use of any battery, charger, or accessory made by Anton/ Bauer with any battery, charger or accessory not manufactured, The liability of Anton/Bauer hereunder is expressly limited to a claim produced or sold by Anton/Bauer. Anton/Bauer only authorizes the use for repair or replacement of the Product or as otherwise stated of original Anton/Bauer products with this Product. Use only original herein at Anton/Bauer’s sole discretion. Notice of any claim under Anton/Bauer equipment with this Product. this warranty shall be delivered to Anton/Bauer during the period of the warranty and the Product shall be returned with its packaging promptly, at your expense, to an Anton/Bauer Customer Support...
Page 12
Approved Copy The following are trademarks of Anton/Bauer, Inc.: Anton/Bauer, Anton/Bauer logo and parallelogram design, Aspekt, Automatique, DataTap, DIONIC, Elipz, Egripz, Elightz, Essentialz, Gold Mount, HubZ, HyTRON, Impac, Interactive and design, LifeSaver, Logic Series, Logic Series Logo, Maxx man logo design, Nexus, PowerStrap, Proformer, Probe, ProPac, RealTime, Satellight, Snap-On, Stasis, Stasis Flex, Tandem, TrimPac, Ultrakit, Ultralight, “One World.
Need help?
Do you have a question about the Anton Bauer POWERCHARGER DUAL 2702 and is the answer not in the manual?
Questions and answers