Installation, use and maintenance guide PVERTICAL INDEX 1 – INTRODUCTION..........................5 2 – TECHNICAL CHARACTERISTICS...................... 7 3 – GENERAL DESCRIPTION ........................8 4 - INSTALLATION ..........................10 5 – DESCRIPTION OF THE CONTROLS ....................13 6 - OPERATION OF THE HANDHELD CONTROL THERMOCOMFORT (OPTIONAL) ......20 7 –...
Page 4
DECLARATION OF PERFORMANCE ACCORDING TO REGULATION (EU) 305/2011 Codice di identificazione unico del prodotto-tipo: PVERTICAL Modello, lotto, serie ai sensi dell'articolo 11, paragrafo 4: PVERTICAL Unique identification code of the product type: Model, batch or serial number required under Article 11(4):...
Page 5
Installation, use and maintenance guide PVERTICAL IT – SCHEDA PRODOTTO (UE 2015/1186) IT – MARCHIO EN – PRODUCT FICHE (EU 2015/1186) EN – BRAND FR – FICHE PRODUIT (UE 2015/1186) FR – MARQUE THERMOROSSI S.P.A. NL – PRODUCTGEGEVENSBLAD (EU 2015/1186) NL –...
Furthermore, Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
Installation, use and maintenance guide PVERTICAL ATTENTION: Before every use make sure that the brazier is clean and positioned correctly in its seat, check that the ash pan is clean and that the firebox door is firmly closed and tight.
2 – Thus the top door will open. Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
Page 10
FIGURA 6 FIGURA 9 Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. FIGURA 7...
CANNA FUMARIA FLUE OUTLET Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto Descrizione...
ATTENTION: the control panel must be placed in an area where the operating temperature remains below 40°C Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
Page 13
Moreover, a suitable windbreak fitting must be installed in the duct’s terminal. Il presente disegno è di proprietà esclusiva di THERMOROSSI S. p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto...
Installation, use and maintenance guide PVERTICAL 5 – DESCRIPTION OF THE CONTROLS The appliance, when operating, could be hot to the touch, particularly the door of the combustion chamber: take care when handling the appliance components. Your appliance has obtained the CE marking and has been made to run for at least one hour to check that it functions correctly.
Installation, use and maintenance guide PVERTICAL Display The following information can appear on the display: Displays the preset combustion power, and consequently the pellet consumption, by the number of bars that are lit up around the flame symbol, using this logic:...
Installation, use and maintenance guide PVERTICAL After a few seconds the following screen will appear on the display: 2) Now press the Scroll Buttons to change the day of the week; each dot corresponds to one day of the week (e.g. 1 corresponds to Monday, 2 correspond to Tuesday, etc...).
Page 17
Installation, use and maintenance guide PVERTICAL 3) Now press the Scroll Buttons to select the hour at which you wish the appliance to start up automatically (ON1). Once the hour has been set, confirm the value by pressing the Flame Button.
Installation, use and maintenance guide PVERTICAL I press the Ventilation button once again to copy all the cycles programmed for Tuesday to Wednesday. The following screen will appear: Using the same logic we can copy the programmed cycles to the other days.
Page 19
Installation, use and maintenance guide PVERTICAL Press the Menu Button three times quickly and the following box will appear: After a few seconds the following screen will appear on the display: To change the operating level, hold down a Scroll Button while simultaneously pressing the other Scroll Button.
Page 20
Installation, use and maintenance guide PVERTICAL The Thermocomfort function is automatically disabled when the appliance is OFF. It automatically reactivates at the next START To disable the THERMOCOMFORT function simply repeat operations 1 and 2, but this time select the OFF command. The function will be disabled immediately.
Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore.
Page 22
Installation, use and maintenance guide PVERTICAL Flick the main switch upwards (11): Connect the radio control to the mains power supply by means of the supplied battery charger. The radio control must be recharged for at least 24 hours, as the rechargeable batteries could be partially or completely empty. Repeat the same procedure every time the radio control batteries discharge.
Page 23
Installation, use and maintenance guide PVERTICAL Attention: it is possible that, due to radio interference, the commands sent to the generator will not be implemented. When using this program the infrared remote control supplied cannot be used. Attention: the power and the ventilation depend on the preset target temperature, if the required temperature is too high or not reachable the appliance could operate at maximum power for long periods of time.
Page 24
Devices or parts returned for replacement become the property of Thermorossi S.p.A. The presence of any irregular black-blue lines on the display, also present when de-energised and/or battery flat or missing, indicate that the glass screen of the display is damaged following a fall or impact: in this case the breakage is not covered by the warranty.
Installation, use and maintenance guide PVERTICAL 7 – USE OF THE APPLIANCE 7.1 DESCRIPTION OF THE OPERATING STAGES START: has a duration of approx. 20 minutes, during this phase the appliance is programmed to light the flame. The appliance will not accept power variations in the firebox.
Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto...
Installation, use and maintenance guide PVERTICAL 8 - ADDITIONAL ROOM TEMPERATURE THERMOSTAT / ADDITIONAL CHRONOTHERMOSTAT The appliance can be connected to an additional room temperature thermostat or to an additional chronothermostat: For the additional room thermostat connect the cables directly to terminals 7-8 of the terminal block CN7 on the board.
Page 28
ATTENTION: Use N.O. (normally open) contacts for the connection to the chronothermostat. ATTENTION: In the event of connections to the chronothermostat Thermorossi S.p.a. shall not be held responsible for the appliance not starting up, smoke leaks or breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
Installation, use and maintenance guide PVERTICAL 9 - CLEANING AND MAINTENANCE 9.1 FOREWORD Before commencing any operation switch off the appliance and disconnect it from the electric power outlet. Your pellet appliance needs maintenance; it requires a few simple, basic but frequent control and general cleaning operations. This will guarantee consistently safe and smooth operation and optimal efficiency of the appliance.
Page 30
Installation, use and maintenance guide PVERTICAL FIGURE 1 FIGURE 2 Page 29...
Page 31
Installation, use and maintenance guide PVERTICAL FIGURE 3 FIGURE 4 Page 30...
Page 32
Installation, use and maintenance guide PVERTICAL FIGURE 5 FIGURE 6 FIGURE 7 Page 31...
Page 33
Installation, use and maintenance guide PVERTICAL FIGURE 8 Page 32...
The batteries are guaranteed for 6 months. Attention: Use only the battery charger provided by Thermorossi S.p.a. The use of any other type of battery charger will invalidate the product warranty. Flat batteries must be removed and safely disposed of. Use rechargeable AAA 1.2 V min.
Installation, use and maintenance guide PVERTICAL 10 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 10.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
Installation, use and maintenance guide PVERTICAL 10.3.2 FLUE OUTLET / FLUE SYSTEM COMPONENTS Components and accessories of a chimney Every chimney must have minimum number of components as laid down by standard UNI EN 10683 which are also indicated in the figure on the left.
Page 37
Installation, use and maintenance guide PVERTICAL The flue outlet must be built in compliance with UNI 10683. The smoke exhaust shown in the following figures is the best solution to ensure the discharge of smoke even when the fan is not operational, such as for example if there is an electrical power failure.
ATTENTION: The appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance.
Ventilatore ambiente Room fan Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito secondo i termini di legge in vigore. Prodotto Descrizione...
Installation, use and maintenance guide PVERTICAL 13 - INFORMATION FOR THE SKILLED TECHNICIAN 13.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
Page 41
Installation, use and maintenance guide PVERTICAL 13.3 TROUBLESHOOTING CAUSES-SOLUTION PROBLEM POSSIBLE CAUSE SOLUTION CLEAN THE BRAZIER AS INDICATED IN THIS USE AND PELLET TANK IS EMPTY MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH THE FOLLOWING ALARM IS SHOWN ON THE DISPLAY “NO PELLET”...
Page 42
Installation, use and maintenance guide PVERTICAL PROBLEM POSSIBLE CAUSE SOLUTION ROOM TEMPERATURE THERMOSTAT SET TOO LOW, APPLIANCE OPERATES THE APPLIANCE NEEDS TO RUN FOR MORE HOURS AT A INTERMITTENTLY HIGHER POWER; SET A HIGHER ROOM TEMPERATURE THE APPLIANCE SHOULD OPERATE FOR MORE TIME AND...
Page 43
Installation, use and maintenance guide PVERTICAL F ire L o v e rs Via Grumolo, 4 (Z.I.) 36011 Arsiero (VI) - ITALY Fax 0445.741657 - www.thermorossi.com - info@thermorossi.it Page 42...
Need help?
Do you have a question about the PVERTICAL and is the answer not in the manual?
Questions and answers