ALTUS Nexto NX2025 Manual

24vdc 8 do monitored module

Advertisement

Quick Links

24Vdc 8 DO Monitored Module
Nexto Series
Doc. Code: CE114409
Product Description
Nexto Series is a powerful and complete Programmable Logic Controller (PLC) Series with unique and innovative features.
Due to irs flexibility, smart design, enhanced diagnostics capabilities and modular architecture, Nexto is suitable for control
systems ranging from medium to high-end large applications. Finally, its compact syze, high density of points per module
and superior performance, allow Nexto Series to be applied in small automation systems with high performance
requirements, such as manufacturing applications and industrial machines.
The Series has a wide variety of CPUs, I/O and communication modules with feature to fit requirements in diferente kinds
of applications. The options available cover from standard automation systems, high-availability applications where
redundancy is major requirement, distributed applications to functional safety systems.
The NX2025 module offers 8 monitored digital outputs, occupying only one position in the rack. Finally, the Nexto Series
has some innovative features for diagnostics and maintenance such as Electronic Tag on Display, Easy Plug System and
One Touch Diag.
Ordering information
Included Items
The product package contains the following items:
NX2025 module
20-terminals conector with wire holder
Installation guide
Product Code
The following code should be used to purchase the product:
NX2025
Related Products
The following product must be purchased separately when necessary:
Altus S. A.
Its main features are:
08 outputs in a single width module
Drive device redundancy, ensuring the safe state of the outputs in case of failure
Possibility to use two outputs in parallel to drive the same field device, increasing availability, with
integrated diodes
Diagnosis of failure causes
Galvanic isolation between outputs and internal logic
Short circuit and overload protection
Protection against surge voltage
Open loop diagnostics
Display for module diagnostics and output state indication
Easy Plug System
One Touch Diag
Electronic Tag on Display
Code
Description
24Vdc 8 DO Monitored Module
NX2025
Revision: A
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Nexto NX2025 and is the answer not in the manual?

Questions and answers

Summary of Contents for ALTUS Nexto NX2025

  • Page 1 20-terminals conector with wire holder  Installation guide Product Code The following code should be used to purchase the product: Code Description NX2025 24Vdc 8 DO Monitored Module Related Products The following product must be purchased separately when necessary: Altus S. A.
  • Page 2: Innovative Features

    Product Design Award 2012: Nexto Series was the winner of iF Product Design Award 2012 in industry + skilled trades group. This award is recognized internationally as a seal of quality and excellence, considered the Oscars of the design in Europe. Altus S. A.
  • Page 3: Product Features

    Standards Module dimensions (W x H x D) 18,00 x 114,62 x 117,46 mm Package dimensions (W x H x D) 25,00 x 122,00 x 147,00 mm Weight 200 g Weight with package 250 g Conformal coating Altus S. A.
  • Page 4 Using the module under these conditions can cause irreversible damage. Minimum Limit Current: The minimum limit current is the current below which the module indicates open load. Altus S. A.
  • Page 5: Connector Pinout

    0 Vdc 24 Vdc 0 Vdc 24 Vdc Mechanical Assembly The mechanical and electrical mounting and the connector pin insertion and removing for single hardware width I/O modules are described at Nexto Series User Manual – MU214600. Altus S. A.
  • Page 6: Physical Dimensions

    24Vdc 8 DO Monitored Module NX2025 Nexto Series Doc. Code: CE114409 Revision: A Physical Dimensions Nexto Series User Manual - MU214600 should be consulted for general measurement of installation panel. Dimensions in mm. Altus S. A.
  • Page 7: Process Data

    Dark" Test: The "Dark" test generates a shutdown pulse on the connected outputs for a maximum user-specified time. Its purpose is to diagnose faults in the module output circuits and short circuits in the field wiring. The "Dark" Time, which Altus S. A.
  • Page 8: Maintenance

    Bus: I/O Mapping tab. Maintenance Altus recommends that all module connections be checked and that dust or any type of dirt on the outside of the module be removed every 6 months. The NX2025 module offers five important features to assist the user during maintenance: Electronic Tag on Display, One Touch Diag, Status and Diagnostics Indicators, Web Page with Complete List of Status and Diagnostics, and Diagnostics via Variables.
  • Page 9 CPU is and the CPU. in RUN mode. Blinking Reserved In this case the module Blinking Fatal hardware fault Hardware fault must be returned to the 1 (Higher) manufacturer. Altus S. A.
  • Page 10 There are two different ways to access diagnostics in the user application: using symbolic variables with AT directive or addressing memory. Altus recommends use symbolic variables for diagnostic accessing. The table below shows all available diagnostics for this module and their respective memory address, description, symbolic variable and string that will be shown on the CPU graphical display and web.
  • Page 11 TRUE – Module has switch failure FALSE – Diagnostics switch ok OTD SWITCH ERROR bOTDSwitchError FALSE – Calibrated module TRUE – External supply with voltage below 19 EXTERNAL SUPPLY bExternalPowerSupply FALSE – External supply with voltage above 19 6..7 Reserved Altus S. A.
  • Page 12 AT directive is used to map the symbolic variables in the addressing memory. The directive AT is a reserved word in the MasterTool IEC XE, that uses this directive to declares the diagnostics automatically on a symbolic variables. All symbolic variables declared automatically can be found inside of Diagnostics object. Altus S. A.
  • Page 13 Spanish MU214305 MU299609 MasterTool IEC XE User Manual English MU299048 Manual de Utilização MasterTool IEC XE Portuguese Manual Del Usuario MasterTool IEC XE Spanish MU299800 MU214603 Nexto Series HART Manual English Manual HART Série Nexto Portuguese MU214003 Altus S. A.

Table of Contents