Foreword
The non contact Infrared body thermometer operating Instructions intend to provide
Only body mode was reviewed and certi�ied by noti�ied body.
the necessary information for proper operation of HTD8813, thermometer model.
General knowledge of Infrared thermometer and an understanding of the features and
functions of the HTD8813 thermometer model are prerequisites for proper use.
The non contact infrared body thermometer is a medical device, and can be used
Please read the manual �irst before using it, if not fully understand the usages, please
repeatedly, which using life is 5 years.
stop using the thermometer.
Do not operate any of the models HTD8813 thermometer without completely
reading and understanding these instructions.
Notice
Purchase or possession of this device does not carry any express or implied license to
use with replacement parts which would, alone or in combination with this device, fall
within the scope of one of the relating patents.
For further information contact:
Room 801, 802, 803, 804,901,
2# Building Scienti�ic Research Center, Songhu
Hetaida Technology Co., Ltd.
Intelligent Valley, No.6 Minfu Road, Liaobu Town, Dongguan City, Guangdong Province,
P.R.China
Tel:+860769-83326886
Contact: Tom. Chen
E-mail: tomchen@hetaida.com.cn
Catalogue
Safety Information
Catálogo
5-Limpieza, cuidado y almacenamiento
Share Info Consultant Service LLC Repräsentanzbüro
Heerdter Lohweg 83, 40549 Düsseldorf
Tel: 0049 1767 0057022
Fax:0049 1767 0057022
Email: eu-rep@share-info.com; info@share-info.com
Safety Information
This device may only be used for the purposes described in these instructions. The
manufacturer cannot be held liable for damage caused by incorrect application.
The noncontactinfrared body thermometeris designed to minimize the possibility of
hazards from errors in the software program by following sound and lightengineering
design processes, Risk Analysis and Software Validation.
Warning
Warnings are identi�ied by the WARNING symbol shown above.
The NonContact Infrared Body Thermometer is to be operated by consumers in the
Directions for Use, all precautionary information, and speci�ications should be read
home setting and primary care setting as screening tool. This manual, accessories,
before use.
This product is designed to measure human body temperature on the forehead. Do
not use it for any other purpose.
This product is intended in the home setting and primary care setting as screening
tool.
3
5
10
14
15
16
16
17
18
22
26
28
33
37
38
39
39
40
41
45

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HTD8813 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hetaida HTD8813

  • Page 1: Table Of Contents

    General knowledge of Infrared thermometer and an understanding of the features and Email: eu-rep@share-info.com; info@share-info.com functions of the HTD8813 thermometer model are prerequisites for proper use. The non contact infrared body thermometer is a medical device, and can be used Safety Information Please read the manual �irst before using it, if not fully understand the usages, please...
  • Page 2: 1- Overview

    Intended Use The HeTaiDa Non Contact Infrared Body Thermometers are designed to be used for intermittent measurement and monitoring of human body temperature by consumers in the home setting and primary care setting as screening tool.
  • Page 3: 2- Operation

    Technical Speci�ications Dimension and Weighting Weight (without batteries) Size L:138mm X W:95mm X H:40mm Compliance Equipment classi�ication Item Compliant with Safety Standards: EN 60601-1: 2006+A1:2013, EN 60601-1-2: 2015 Type of protection Internally powered equipment (on battery power) Degree of protection Non Applied part Front panel and case labeling EN ISO15223-1:2016...
  • Page 4: 3-Troubleshooting

    Green means ready for next measurement. When 37.4℃-38.0℃, it's yellow ,means temperature is above 38.1℃, it's red , means high fever. Please take action to cool down HTD8813 as below step: slight fever warning. Please pay attention to body temperature. When the body 1)Unit Set-F1 or go for a doctor.
  • Page 5: 5-Cleaning, Care And Storage

    Enquire about the options for environment-friendly and appropriate disposal. Take local regulations into account. 2. Please report to HeTaiDa Technology Co., Ltd. if any unexpected operation or events occur. 3. The thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the use instructions, periodic re-adjustment is not required.
  • Page 6: 9-Body Temperature

    34.0~43.0℃. Full responsibility for the conformance of this product to the 901, 2# Building Scienti�ic Research Center, Songhu Intelligent Valley, No.6 Minfu standard is assumed by(Hetaida Technology Co., Ltd. Add: Room 801, 802, 803, 804, Road, Liaobu Town, Dongguan City, Guangdong Province, P.R.China...
  • Page 7: Información De Seguridad

    Lea primero el manual antes de usarlo, si no entiende completamente los usos, por Manual de usuario favor deje de utilizar el termómetro. No utilice ninguno de los modelos de termómetro HTD8813 sin haber leído y comprendido completamente estas instrucciones. AVISO La compra o posesión de este dispositivo no conlleva ninguna licencia expresa o...
  • Page 8: 1-Descripción General

    7. Modo super�icial 6. Carcasa de plástico 13. Fahrenheit/Celsius Los Termómetros de infrarrojos corporal sin contacto de Hetaida están diseñados 14. Número de memoria para ser utilizados para la medición intermitente y el control de la temperatura del 15. Indicador de memoria cuerpo humano por los consumidores en el entorno doméstico y en el entorno de...
  • Page 9: 2-Funcionamiento

    La última temperatura registrada antes de que el termómetro se apague se almacenará en la memoria. Hasta 50 para HTD8813. Para los modelos HTD8813 como se describe en los pasos siguientes: Con�iguración general y uso 1) En el estado de arranque o apagado, pulse brevemente el botón MEMO para ver el 2) Una celda de memoria vacía muestra "---°C"...
  • Page 10: 3-Solución De Problemas

    HTD8813 como se describe en los pasos siguientes: 3- Solución de problemas 1) Ajuste de la función-F1 En el modo de arranque . Pulse prolongadamente el botón SET para entrar en F1, y Fahrenheit, pulse el botón SET para con�irmar los ajustes de las unidades (el valor MENSAJE SITUACIÓN...
  • Page 11: 7-Garantía

    Hetaida Technology Co. No abra o repare el dispositivo por sí mismo. Emisiones de RF CISPR 11 Grupo 1 2. Informe a Hetaida Technology Co., Ltd. si se produce cualquier operación o evento Clase B Emisión de RF CISPR 11 inesperado.
  • Page 12: 9-Temperatura Corporal

    ASTM (E1965-98), excepto la cláusula 5.2.2. Muestra la temperatura del LTE Banda 7 5240 Dirección: Room 801, 802, 803, 804, 901, 2# Building Scienti�ic Research Center, 5100- este producto con la norma es asumida por (Hetaida Technology Co., Ltd.). WLAN 802.11 a/n Modulación de 5500 5800 pulso 217 Hz Songhu Intelligent Valley, No.6 Minfu Road, Liaobu Town, Dongguan City, Guangdong...

Table of Contents