  • Page 1 Icetro America...
  • Page 2 ▣ Key specification Item Specification Requirement Electricity 208~230V/60Hz/3phase 250VAC, 3-Phase, 30A, 3 -Pole, 4Wire, NEMA L15- 30P plug is required Max. 35A, Operation: 20 Minimum 30Amp circuit ~23A breaker is required. Power consum 7400W ption Main(Freezer) 5089 Btu/h per 1 compr compressor BT essor Refrigerant...
  • Page 3 ▣ Measurement of supplying voltage Explanation Picture Remove the cover of the control box. 1) Remove the cover of the control box. 2) Connect the power cord and turn on the machine. 3) Measure the voltage power lines at the terminal block. (Use clamp meter or multi-tester) Measure the supplied...
  • Page 4 ▣ Adjust the voltage between the number of real supplied and machine recognize Explanation Picture 1) If the measured value is different with the value of “1-3”, then need to Variable Resistor adjust the value with the variable resistor on the control PCB.
  • Page 5 ▣ Adjust the voltage between the value of real supplied and machine recognized Explanation 1) Adjust the value of “4-13-1”. : Approximate value with the “1-3”. - “4-13-1” : Supply Voltage Criteria 2) Adjust method for “4-13-1”. - Press the “Set” and “Select” button at the same time for 3 seconds over. - Insert the password.
  • Page 6 ▣ No Load Amp Setting(Viscosity setting) Explanation 1) Please check the below items pressing lightly the “Set” button. ① 1-1 : Soft ice cream level setting value(Amps) → The displayed value indicates how much higher from the no load Amps(1-2) the soft ice cream level is.
  • Page 7: Making Ice Cream

    ▣ Making Ice Cream Explanation 1) Set the value of “3-1” properly after you check the no load amp of “1-2”. (Please leave factory setting as it. Please change it only if there is an issue with viscosity.) 2) Pour mix in the hopper and please wait until the mix flows into the cylinder sufficiently.