POWER ENTRY MODULE EMI FILTERS
INTRODUCTIONS
1. AR series is designed as a high performance, two-stage filter for
low impedance load with better noise attenuation than AK series
in low frequency applications such as switching power supplies.
2. Fuse holder designed for one IEC 5x20mm fuse. Safety interlock
prevents fuse removal with line plug inserted (Use only with 250V
fuse).
3. All part numbers are UL recognized, CSA certified and VDE
approved.
COMPONENTS
PART NO.
C1 (uF) L1 (mH) L2 (mH) Cy (pF)
03AR1/2/3
0.1
1.5
03AR2D/3D
0.033
06AR1/2/3
0.1
0.7
06AR2D/3D
0.015
2.5
06AR4
0.1
0.7
ELECTRICAL SCHEMATIC
AR1/4 WITHOUT POWER SW
L
F
L
SW1
C1
I
L1
N
E
N
G
FIG. A
C2:0.1uF
TYPE & RATED CURRENT
DELTA PART NO.
RATED CURRENT
115VAC
250VAC
IEC CONNECTOR
FUSE HOLDER
POWER SWITCH
VOLTAGE SELECTOR SW
ELECTRICAL SCHEMATIC
1. Single-pole UL, CSA & VDE approved, VDE-6A at 250VAC.
Electrical lifetime: 50,000 cycles.
Maximum inrush current: 50A.
2. Double-pole UL, CSA & VDE approved, VDE-4A at 250VAC.
Electrical lifetime: 10,000 cycles.
Maximum inrush current: 50A.
3. Voltage selector SW -UL, CSA & VDE approved
Current rating: 10A at 125VAC; 5A at 250VAC.
R ( )
9
2200
1M
9
1.5
2.5
0.7
3300
2.2M
2.5
AR3/4 ONLY
L'
Cy
L
R C2
C3
O
L2
A
N' D
Cy
G'
C3:0.1uF
AR1
AR2
AR2D
6A
6A
6A
6A
6A
4A
1
SP
DP
FIG. A
FIG. A
FIG. B
SPECIFICATIONS
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
MINIMUM INSERTION LOSS IN dB
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
RATING
.15
03AR
40
06AR
34
06AR2D,3D
34
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
03AR
6
06AR
5
06AR2D,3D
10
L
F
L
SW1
C1
I
N
E
N
G
AR3
AR3D
6A
6A
5A
4A
2
1
2
SP
DP
3
3
REAR
REAR
REAR
FIG. A
FIG. B
FIG. A
4-3
FREQUENCY-MHz
.50
1.0
5.0
10
60
60
45
40
55
56
40
35
60
60
45
40
45
55
50
45
25
60
50
45
10
50
50
45
AR3D ONLY
L'
Cy
L
R
C2
C3
O
L1
L2
A
D
N'
Cy
FIG. B
AR4
6A
6A
3
V
D
E
30
30
25
30
40
35
40
G'

Advertisement

loading
Need help?

Need help?

Do you have a question about the Network Adapter AR and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta Electronics Network Adapter AR

  • Page 1 SERIES POWER ENTRY MODULE EMI FILTERS INTRODUCTIONS 1. AR series is designed as a high performance, two-stage filter for low impedance load with better noise attenuation than AK series in low frequency applications such as switching power supplies. 2. Fuse holder designed for one IEC 5x20mm fuse. Safety interlock prevents fuse removal with line plug inserted (Use only with 250V fuse).
  • Page 2 MECHANICAL CONSTRUCTION AR2, AR2D AR3, AR3D AR4(without power switch) Suggested thickness of mounting panel is from 0.04 to 0.07 inch suggest mounting cutout 2.65 67.3 2.57 65.3 2.65 67.3 2.65 67.3 2.57 65.3 R0.04Max. 2.6 0.003 66.0 1.059 26.9 1.059 26.9 INCH UNIT:...

This manual is also suitable for:

Ar series