Product Information Thank you for choosing Amoul Man. For the correct use of the product, please read and understand this Operator’s Manual carefully before use. After reading, please keep this Manual in an easily accessible place. This Manual introduces the product according to the most complete configuration, and some of the content may not be applicable to the model you bought.
Unless otherwise specified, the terms "Ambulanc" and "the Company" in this Operator’s Manual refer to AMBULANC (SHENZHEN) TECH. CO., LTD. Unless otherwise specified, the term "patient simulator" in this Manual refers to the Amoul Man. The product pictures in this Operator’s Manual are for reference only and are not identical to the actual product, all subject to the actual product.
Page 4
Before starting actual training, the trainer should inform the students how to use the defibrillator correctly and remind them of the potential dangers of not following safety rules. Amoul Man is very sensitive to moisture, so please ensure that it is not wetted, or it may cause internal short circuits.
1. CPR Introduction Cardiac pulmonary resuscitation (CPR) is a series of actions established by the American Heart Association (AHA) in its "Chain of Survival" to make emergency response to cardiac arrest, which includes five links. Figure 1-1 1. Early recognition and call for emergency assistance If a patient suddenly falls to the ground, rescuers should quickly check if the patient has no response and breath, immediately dial the emergency call, loudly call for help, and activate the emergency medical service system (EMSS) and request to bring an automated external defibrillator (AED).
Page 7
Wait for the results of heart rhythm analysis. If a defibrillation indication is issued, press the "Shock" button, or the defibrillator automatically initiates the shock. 4. Effective advanced life support Start nursing work of advanced life support to restore natural cycle. A series of resuscitation measures implemented by professional rescuers and medical staff using first-aid supplies and drugs, mainly including the establishment of artificial airways, mechanical ventilation, cycle assistance instruments, application of drugs and liquids, electric defibrillation, evaluation of condition and...
Amoul Man has a visual circulation system that can simulate important ECG signals in the human body, supporting advanced life rescue training. Amoul Man has the size of a normal adult and provides realistic anatomical features of the human body. It is wirelessly connected to an Android device equipped with an Amoul application through Bluetooth, and CPR operations can be viewed in real time through the Amoul application.
2.2. Rotatable head The Amoul Man's head can be rotated left and right to simulate a real-life rescue scenario where a patient's airway is blocked by foreign objects, and the rescuer turns the face to one side to facilitate the removal of foreign objects from the patient's mouth.
Figure 2-1 Front view Part Description ①&⑧: buckle Used to buckle the upper body skin of Amoul Man ②: RA ECG lead buckle Used to connect the RA ECG lead (only for AM9-H/AM9-W model) ③: Defibrillation electrode Used to connect the RR defibrillation plate electrode (only for...
Description ①: Mounting holes for Used to install and secure the arms arms Used to turn on Amoul Man (not available for AM3-H and ②: Power switch AM3-W models) ③: Power adapter Used to connect the power adapter (not available for AM3-H and...
3.3. Signal indicator light Figure 2-3 Signal indicator light Part Description When the compression depth and rate are correct, the head indicator light will light up. ①: Indicator light for normal cycle On the contrary, if any operation is incorrect, the head indicator light will not light up.
• Before starting actual training, the trainer should inform the students how to use the defibrillator correctly and remind them of the potential dangers of not following safety rules. • Amoul Man is very sensitive to moisture, so please ensure that it is not wetted, or it may cause ...
If you want to use it again, turn on the power and then restart it. The power consumption of the Amoul Man is very low in the standby mode, and please turn off the power if the Amoul Man will not be used for long.
Figure 4-1 Menu interface 3.Turn on the power switch of the Amoul Man (the "Bluetooth" button of Amoul Man flashes every 2s), click on "Searching Available Manikin", and select the manikin from the Bluetooth list. If the list is not displayed, click on "RESCAN". After successful connection, the "Bluetooth" button light of the Amoul Man will be constantly blue.
Page 16
Figure 4-4 Self-training Click on "Self Training" and select between the training content: One-man rescue, Two-man rescue, Compression Only, and Ventilation Only. After entering the training interface, click on "Start Training" to receive a single item training. Figure 4-5 One-man rescue Click on "Time-Based Training", set the training time in the pop-up page, click on "Start Training", and...
Figure 4-9 Supervision Click on "Supervision" to select between the training content: One-man rescue, Two-man rescue, Compression Only, and Ventilation Only. After entering the training interface, you can supervise up to 6 trainees. Click "Start Training" to simultaneously train all trainees in a single item. Trainees' training data...
Page 19
2. Training result data can be shared and downloaded through click the icon in the bottom left corner of the evaluation interface; 3. More detailed instructions on the operation of the Amoul application can be obtained through click the icon in the upper left corner of the interface.
The matching clothes are made of 50% cotton and 50% polyester fiber and can be rinsed and dried with water at no higher than 40°C (104°F). 7. Product Configuration No. Name Unit Quantity Basic Standard Upgraded High-configured 1 Amoul Man Unit ● ● ● ●...
8. Quality Assurance The warranty period for the Amoul Man is 1 year, and the warranty does not cover consumables. To make after-sales request for product quality, you must provide proof of buying the product. If the proof or proof of receipt is difficult to identify, you are not entitled to free after-sales service.
Page 22
Federal Communications Commission (FCC) Statement.This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation.Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.