Download Print this page

Tinkerine Studio Face Shield Lite Cleaning

Advertisement

Quick Links

A
PETG visor
D
Knit
elastic
band
Tinkerine Face Shield Lite is not sterile. Since the conditions and methods of assembly and use of Tinkerine Face Shield Lite are beyond the manufacturer's control, the manufacturer expressly disclaim any and all liability arising from any assembly
and use of Tinkerine Face Shield Lite. NO WARRANTY OF FITNESS FOR ANY PARTICULAR PURPOSE, WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, IS MADE CONCERNING TINKERINE FACE SHIELD
LITE. The user should thoroughly test any application before use. By assembling and using Tinkerine Face Shield Lite, the user does so at their own risk and waives all claims against the manufacturer. The user releases the manufacturer from all
liability, whether due to foreseeable or unforeseeable risks, relating to Tinkerine Face Shield Lite. The user is solely responsible for their assembly and use of the Tinkerine Face Shield Lite. The manufacturer is not responsible for errors or omissions
relating to Tinkerine Face Shield Lite. The manufacturer does not provide any medical advice.
MANUFACTURED BY
Tinkerine Studios Ltd.
B
Forehead strap
C
Clips
#213A 8275 92nd St
Delta, BC V4G 0A4
Cleaning Tinkerine Face Shield Lite
Step 1. Precautions for cleaning
Before you begin, protect yourself by wearing gloves, a face
mask, and another face shield if possible.
Clean and disinfect the working surface thoroughly.
Only clean one face shield at a time to avoid cross-
contamination.
Step 2. Disassembling the face shield
Disassemble the face shield in the reverse order of the
assembly:
i.
Remove the knit elastic band
ii.
Remove the clips
iii. Remove the forehead strap
Due to the porosity of the knit elastic band and the 3D printed
clips, we cannot guarantee that these parts are fully sanitizable
after being used. We recommend that they are replaced
regularly at the user's discretion. They should be replaced
immediately if damaged or upon direct contact with anyone
with flu-like symptoms.
Step 3. Cleaning the PETG visor and the forehead strap
It is recommended to fully submerge the PETG visor and the
forehead strap in a disinfectant solution to ensure complete
sanitization before and after every use.
After removing the visor and the strap from the solution, allow
a few minutes for the parts to dry. Wipe down any remaining
disinfectant droplets with a clean paper towel.
If submerging is impossible, thoroughly spraying the visor and
the strap with a disinfectant can also be effective. Allow a few
minutes to dry. Wipe down any remaining droplets.
Our recommended disinfectants are:
Isopropyl alcohol (70%)
Hydrogen peroxide (28%)
To find out more about specific cleaning products, please refer
to the
list of disinfectants approved by Health
Step 4. Reassembling the face shield
To reassemble to face shield, use the disinfected PETG visor and
forehead strap with a set of new replacement parts. Refer to the
assembly manual.
www.tinkerine.com
contact@tinkerine.com
Canada.
604-288-8778
1-844-846-5377

Advertisement

loading
Need help?

Need help?

Do you have a question about the Face Shield Lite and is the answer not in the manual?

Questions and answers

Summary of Contents for Tinkerine Studio Face Shield Lite

  • Page 1 LITE. The user should thoroughly test any application before use. By assembling and using Tinkerine Face Shield Lite, the user does so at their own risk and waives all claims against the manufacturer. The user releases the manufacturer from all...
  • Page 2 Nettoyage de l’écran facial Tinkerine Lite Étape 1. Précautions pour le nettoyage • Avant de commencer, protégez-vous en portant des gants, un masque facial et un autre écran facial si possible. • Nettoyez et désinfectez soigneusement la surface de travail. •...