Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 3
PROPER GROUNDING IS VITAL FOR THE SAFE OPERATION OF YOUR SYSTEM. BRING THE GROUND WIRE TO THE GROUND STUD THAT IS LABELLED “GND” OR “G1”. YOU MUST CHOOSE THE PROPER CONDUCTOR SIZE. SEE NATIONAL ELECTRICAL CODE ARTICLE 250-95, OR THE RELATED LOCAL APPLICABLE CODE Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 4
DO NOT ALLOW ANY METAL SHAVINGS TO GET INTO RELAYS OR CONTACTORS OR IN BEHIND ELECTRONIC COMPONENTS, AS THIS COULD CAUSE SERIOUS DAMAGE TO PERSONNEL AND/OR EQUIPMENT Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
(L1, L2, L3) at the main line disconnect 3.6 PLC Start Up Instructions Before making the final wiring connections note that the Dupline Master Module indicators and PLC status are correct as follows: Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
T7.1 and T7.2 b. T7.2 and T3.8 Both readings should be approximately 24VAC. If satisfactory, turn off the lighting disconnect and carefully replace the travel cable plugs on the designated terminals. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Fire Service. Most codes require that Hall Fire Service (Phase 1) be in effect for the car to return automatically to the main fire landing when the Car Fire Switch is turned to the OFF position. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 8
12 Swipe right for BIT, tap BIT to change, push and hold 4 seconds to toggle BIT. 13 Swipe left to show Data screen. 14 Push and hold data pointer to change INT 30, INT 31 and 32 shown on this page. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 9
D9 connector; the “+” (5VDC to 24VDC) terminal is closest to the aerial. Slide the power switch towards the terminals. Refer to the US Converters Manual for a full description of the WiFi adapter. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 10
Note: iPad is shown below; Android devices are similar. Open a browser on the mobile device and go to address 192.168.0.3. At the Login screen, enter the user name admin and password admin and tap Login. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 11
At the Advanced tab, change the MODBUS Settings - Transfer Mode to Transparent TCP and the Server Port to 502. The Response Timeout can be set to a value between 3000 and 5000. No changes are required on the Security, WiFi, WiFi Wizard, RTC or Status tabs. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 12
Static DNS Server 168.95.1.1 DHCP Settings DHCP Client Disable DHCP Server Enable DHCP Server IP Pool Start 192.168.0.4 DHCP Server IP Pool End 192.168.0.10 DHCP Default Gateway 192.168.0.3 DHCP Server Lease 1440 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 13
Under Serial settings • Set Data Baud Rate to 38400: • Set Data Bits to 8 • Set Data Parity to None • Set Stop Bits at 1 • Set Flow Control to None Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 14
• Set Operation Mode to Socket • Set Connection Type to TCP • Set Server/Client Mode to Server • Set Server Listening Port to 502 • Set TCP Server Connections to 3 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 15
Modbus RTU class 1 Slave identity Fetch/Write Not Used Life Bit Word Swap Poll Interval Timeout 3000 Modbus Max Block Display-Center Scale Use Swipe NOTE The default password to get into the App is 2513. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 16
Modbus Max Block Modbus polling optimizer Use Modbus FC06 Read full bytes Disconnect on timeout Display-Center Scale Lock rotation Center Full screen Hide Action Bar Slide show mode Use Swipe Allow delete Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 17
• Connect your iPhone or iPad and start iTunes. • Click the phone symbol in the top left corner to bring up information on the attached phone. NOTE The default password to get into the App is 2513. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 18
• Click on File Sharing. • Select Odrid HMI from the list and then click on Add Files. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 19
• Select all of the downloaded files and then click Open and you will see the files appear in the right column. • Click Sync. This will transfer the files to your iPhone. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 20
On the start screen (or the Home screen) the Link Status light will be Green if the device is communicating with the PLC. NOTE The default password to get into the App is 2513. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 21
The only time a password is required is if you are leaving the Start screen. If you swipe back to the Start screen, you will have to enter the password again to leave it. NOTE The default password to get into the App is 2513. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
• The Link Status indicator shows that the mobile device is communicating with the PLC. The HELP button displays the HELP screen for this screen. A typical Android screen is shown on the left and an iPad screen on the right. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
The HELP button displays the HELP screen for this screen. It shows a breakdown of the Fault status code. A typical Android screen is shown on the left and an iPad screen on the right. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
• A description of the data being viewed is shown below the actual data. The HELP button displays the HELP screen for this screen. A typical Android screen is shown on the left and an iPad screen on the right. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 25
WARNING: Make sure you change the intended Bit. The description of the Bit is shown by the Bit Number. The HELP button displays the HELP screen for this screen. A typical Android screen is shown on the left and an iPad screen on the right. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 26
The operation of either screen is similar. The factory default menus use the sei_1_* screens. The Large screen (Type c for an iPad or a screen over 9”) is shown below on the right. It uses one screen to enter any Integer between 0 and 47. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 27
To change an a_INT setting, click in the “Logical Value” box for the desired setting, and enter the desired value. Press enter to accept the new value, or ESC to reject it. Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 1 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Disable Short Door Time with Electric Eye a_BIT[13] bit 13 Enable Timed Electric Eye Cutout a_BIT[14] bit 14 Enable Nudging a_BIT[15] bit 15 Enable Infra Red Curtain Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 2 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 29
Car Delayed Time (sec) (sets T4_4_PT) a_INT[13] int 13 Door Stuck Time (sec) (sets T4_0_PT, T4_2_PT, T4_34_PT, T4_36_PT) a_INT[14] int 14 Direction Hold Time on SBC (sec) (sets T4_13_PT) Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 3 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 30
Not Used a_INT[64] Pointer for BIT Settings a_INT[65] Pointer for INT Settings a_INT[66] Value of INT Setting a_INT[67] Shutdown Status Word a_INT[68] Not Used Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 4 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 31
Hold Doors Open on Emergency Power Allow Door Open on Fire2 and Stop Sw 1024 Cycle Doors on Fire and Emergency Power 2048 Not Used Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 5 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 32
5. Timers are adjusted by changing the Project Value of the preset value T4_xx_PT for each timer, where xx is replaced by the Timer Number. For example T4_11_PT adjusts the Homing Timer. A description of each timer Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 6 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 33
Zero in tens column indicates point 3 is OFF. “4” in units column indicates point 4 is ON. Zero in units column indicates point 4 is OFF. Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 7 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 35
Floor Reset Reset Counter C5_2_PT Down Level Counter T4_0_PT T#15s = a_INT[13] Door Stuck (value in seconds) T4_1_PT T#200ms Door Open/Close Delay (value in milliseconds) Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 9 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 36
Sabbath Call Delay (value in seconds) T4_52_PT T#2s Negative Pressure Fault Delay (value in seconds) T4_53_PT T#1500ms Delay After Stop (OSF, ODZ) (value in milliseconds) Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 10 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
= Fault Time Stamp of selected fault. Register Number Description Register Number Description a_FLTLOG[0] Fault Code of Fault 50 (oldest) a_FLTLOG[184] Fault Code of Fault 4 Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 11 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
TRACTION: If the fault code is 103xx, then the fault is a Redundancy Fault involving the Rope Brake monitoring inputs. Use Table 2B to determine the cause of the fault. Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 12 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
To decode the status, compare each digit of the status code with the value at the top of the table for that digit. Read down the column to see which items were true (indicated by “Y”). Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 13 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 41
IDZMON was on and term20X I-02 was off IDZMON was off and term20X I-02 was on, while the car was not running fast speed Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 15 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 42
IRB was ON and ORB and ORBX were off IRB was ON and ORB and ORBC were off IRBC was ON and ORBC was off Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 16 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 43
Usually only one item is on, and that is the cause of the fault. Typical codes would be 20000 except one of the zeroes would be 1, 2, 4 or 8. Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 17 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 44
(indicated by “Y”). Usually only one item in the whole table is true for each fault. 1st Digit (TEN THOUSANDS) [ 12345 ] Fault Code 1-6 or 8-11 or 15 - See Table 1 Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 18 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
To go from minutes to hundredths of an hour, multiply the minutes by 10 and divide by 6. To go from hundredths of an hour to minutes, multiply the last two digits by 6 and divide by 10. Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 19 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Fault Disable Mask (a_INT[46]) then it will not be counted. When the value reaches 1000,000,000 it will be reset to 0, and start counting again. This value is also shown in a_INT[100] and a_INT[101]. Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 20 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 47
EHBY Hall Fire Sw in “Bypass/Reset” H EHON2 Remote Hall Fire Sw in “ON” 1st Ldg Hall Call Button 2nd Ldg Hall Call Button Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 21 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 48
4AGR/3DLR Rear 4 Arr Gong / 3D Lantern 5AGR/3ULR Rear 5 Arr Gong / 3U Lantern 6AGR/4DLR Rear 6 Arr Gong / 4D Lantern In Use Light/Shutdown Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 22 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 49
1. Add adjustments for Traction COT44. on HOLD. 2. Add Status at a_INT[67] for HMI --------------- 3. Show Car and Hall Door Status on HMI Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 23 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 50
Zone Sw Fail) fault, so car that never runs up will return to --------------- bottom ldg. 11-25-09 (INT29=25, TSSA=25001, Sabbath=25002, 2. Prevent Door Close on Inspection. Int38 bit10 enables TSSA+Sabbath=25003) door close from run buttons. --------------- Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 24 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 51
11-14-02 (INT29=12) no demand for the car. The "Park with Gate Open" would not open a closed Gate, it would just leave an open gate Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 25 Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 52
The car should run down and stop at the Virginia Controls, Inc. Savaria Adjustments, 11/30/21 Page 26 Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 53
Allow Run on Boris and Fire Service (ON) Do Not Run on Shutdown and Fire Service Allow Stop at Upper Landing on Shutdown Enable 2nd Hall Fire Switch (2000 Code) (ON) Enable Wisconsin Code (ON) Enable Test Mode (ON) Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 54
06 Enable Rear Opening at 1st Landing - This feature is enabled if there is a rear opening at this landing AND the elevator has selective openings. NOTE: This setting does not have to be enabled if the elevator is non-selective. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 55
(The Electric Eye Input is subject to the Timed Electric Eye Cutout and Nudging, whereas the Safety Edge Input is not.) Note: Door Nudging operation requires an optional Nudging Buzzer output and Reduced Speed Door Closing output. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 56
Inspection, the car may be run down, but not up. This feature requires BORIS circuitry to be installed on the controller. The setting of this feature will not affect the operation of the controller if BORIS is not provided. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 57
40 Enable Negative Pressure Switch - Enable this feature to move the Negative Pressure Switch to Input 1 on the PLC 41 Enable A17 2005 and later Fire Code 42 Enable A17 2007 and later Fire Code Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 58
THIS FEATURE SHOULD NOT BE LEFT ON WHEN THE CAR IS IN NORMAL USE, AS IT DEFEATS KEY SAFETY CHECKING CIRCUITS. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 59
Door Code (See Separate Description) Bit Features (See Separate Description) 2513 Password to Enable DAT Fault Pointer 0-19 (0=Newest) Fault Code from Pointer Fault Status from Pointer 5th Fault Code continued on next page..Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 60
NOTE: If a car call is entered while the doors are open, the door time will be reduced to the “Door Time, Short” setting. This setting is normally 20 tenths of a second (that is 2 seconds). Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 61
Door Open Bell is activated. 16 Hold Car Light After Stop - This is the time delay that the car lighting is left on before energizing the LIT relay, which turn off the car lights. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 62
INT31 and INT32. Refer to the section on Monitoring the I/O Status with the DAT. 1st IO Data - This displays the ¿ rst four data bits, as set by the data pointer in INT30. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 63
To determine the desired value for INT36, add the value for all the Bits that should be on, then enter this value in INT36. The Sabbath run cycle will continue after the Sabbath Input has been turned off until the car has returned to the Main Ldg. Part No. 001360, 13-m07-2023 Virginia PLC Controller Manual...
Page 64
16384 (future) 32768 (future) For example, to enable Power Car Gate (2) which will Park Closed (32) with Automatic Pro Door (4), set INT37 to 2 + 32 + 4 = 38. Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...
Page 65
Bit Features - This value sets additional features that may be determined by Savaria Concord. The proper number should be determined from the chart below (add up the values of the desired features to get the desired number). Value Description...
Page 66
THIS PAGE IS INTENTIONALLY LEFT BLANK Virginia PLC Controller Manual Part No. 001360, 13-m07-2023...