  • Page 1 PT100 Temp Sensor Transmitter UA13 User Manual 2021 | Rev. 1.05 Keep this document nearby so that it may be referred to when needed.
  • Page 2: Table Of Contents

    CONTENTS About this Manual Intellectual Property Rights Notational Conventions Introduction Exteria Accessories Specifications Connecting External Sensor 3-wired PT100 Monitoring from your Computer Installing Software Connecting Sensor to Tapaculo Lite Starting Tapaculo Lite Monitoring from your Smartphone Installing Tapaculo Mobile Starting Tapaculo Mobile Customer Service Information Manufacturer Contact Information Warranty...
  • Page 3: About This Manual

    About Thisdocumentcontainsinstructionsforusageandinstallationof the RADIONODE® UA13. Product specifications and certain this features herein may be subject to change without prior notice. Figures used in this manual are for explanatory purposes only, Manual and may differ from your system depending on installation conditions. Software screenshots may change after software updates.
  • Page 4: Introduction

    Introduction UA13isasensorthatmeasuresthetemperaturewithaPT100. Measurementsaremadebyoneoftwomethods: ● ConnecttheUA13sensortoyourcomputer'sUSBporttouse theTapaculo®Liteprogram. ● ConnecttheUA13sensortoyoursmartphoneviatheUSB gendertousetheTapaculo®Mobileapp. Once power is supplied through the USB port, the sensor will commence initialization. Initialization takes approximately 5 minutes to complete. Measurements may not be accurate until initializationiscomplete. Radionode365,thecloud-basedremotesurveillanceserviceprovided RADIONODE,isavailableforUA13userswithaRN17xWCseriesdata transmitter. For information on how to install and use RN17x WC, seetheinformationprovidedonthewebpagebelow: https://help.radionode365.com/article- categories/ RN17x WC-help...
  • Page 5: Exteria

    Exteria ❶ ❷ ❸ USB2.0 ScrewHole ❹ ❺ Screwforterminal PT100inputterminal...
  • Page 6: Accessories

    Accessories TheUA13comeswiththefollowingaccessories: USBExtensionCable Specifications PT100m.range -200~300°C(±0.625°C) USBPort USB2.0TypeAPlug Power 5V,max50mW consumption 68.5×25×15mm Size -20~80°C,5∼95%RH(noncondensable) Operating conditions Notethattheperformanceoftheexternaltemperature sensorseparatelymaydifferfromwhenitisconnected totheDataLogger.
  • Page 7: Connecting External Sensor

    Connecting External Sensor 3-wired PT100 TurnoverUA13,connectexternalsensorcablefromlefttoright Looseboltonconnectorforconnectingexternalsensorcable Redis+,Whiteis-thatconnectasapicture The UA13 supports 2-wire PT100 temperature ● sensor.TheUA13canmeasureupto1CH ●...
  • Page 8: Monitoring From Your Computer

    Monitoring from your Computer ThischapteroutlineshowtouseTapaculoLite.Formoreinformation on Tapaculo Lite, see the information provided on the web page below: https://help.radionode365.com/article- categories/ tapaculo-lite Installing Toviewsensormeasurementsonyourcomputer,downloadand install the following software package from the RADIONODE Software websiteat www.radionode365.com. ● TapaculoLiteprogram(WindowsorMacversion) ● USBdriversforWindowsforUAproducts Connecting ThesensorcanbeconnectedtoTapaculoLiteviaoneofthe followingmethods: Sensor to ● InsertthesensorintoanavailableUSBportonyourcomputer.
  • Page 9: Starting Tapaculo Lite

    Starting AnewprojectmustbecreatedfirstbeforecombiningTapaculoLite andthesensor.Aprojectmayincludemultiplesensors.Refertothe Tapaculo followingprocedurewhenusingTapaculoLite: Lite Aprojectisafilethatstoresandmanagessensordata. Click Create Project and enter a file name. The new file will containsensorinformation. Searched sensors appear in the left panel. Select a dashboard and sensor, then click Add Device. The sensor will be added to thedashboard.
  • Page 10 Click TimeInterval andselectthemeasurementinterval. Click OK Create Project at the bottom of the menu. The Dashboardmenuwillopenanddisplaymeasurementsofsensors registeredintheproject,andsensorindicatorswillblink. ClickRECatthelower-leftcornertostartloggingdata.The REC buttonwillchangetoSTOP. Toexittheprogram,click STOP .Youcannotexittheprogramuntil dataloggingisstopped.
  • Page 11: Monitoring From Your Smartphone

    Monitoring from your Smartphone This chapter outlines how to use Tapaculo Mobile. For more information on Tapaculo Mobile, see the information providedonthewebpagebelow: https://help.radionode365.com/article- categories/ tpm-manual Installing Searchfor"Tapaculo"onGooglePlay,orclickthelinkbelowtoinstall TapaculoMobileapponyourAndroidsmartphone. Tapaculo https://play.google.com/store/apps/details? Mobile id=com. dekist.mobile TapaculoMobiledoesnothaveaniOSversion. Starting RefertothefollowingwhenusingTapaculoMobile: Tapaculo ConnectthesensortoyoursmartphoneusingtheUSBgender. Mobile TapaculoMobilewillopen.Tap START tostartloggingdata.
  • Page 12 Swiperighttochangesensorsettings. Swipelefttoviewthemeasurementchart. Tap STORAGE toshareyourmeasurementhistorywithothers. MeasurementhistoryissavedasaCSVfile. Datemeasured/tVOCmeasurement/carbondioxideequivalent (orabsolutehumidity)measurement...
  • Page 13: Customer Service Information

    Customer Service Information Manufacturer DEKISTCo.,Ltd.providesrepairserviceandreplacementpartsfor RADIONODEproducts.Torequestcustomerservice,contactusvia Contact oneofthefollowingmethods. Information ● Tel:+(82)1566-4359 ● Fax:(+82)31-8039-4400 ● E-mail:master@dekist.com Warranty Repairsareprovidedfreeofchargeforproductfailureundernormal operatingconditionswithinoneyearoftheproductinstallationdate. Limit of Warrantyrepairsarenotprovidedintheeventof: ● Liability Failurecausedbyunapprovedinstallationmethods; ● Failurecausedbyusernegligence; ● Failurecausedafteralteration,disassembly,orrepairofthe productbyapersonunauthorizedbyDEKIST; ● Failurecausedbycorrosion,falling,submersion,orother improperstoragemethods; ● Failurecausedbynaturaldisasterorotherunforeseen circumstances,suchasstorms,floods,earthquakes,lightning,or abnormalvoltage; ● Servicerequestedforactionsthattheusercantake,suchas replacingconsumables; ● Alterationofthesoftwarethroughdecompilationorthelike...
  • Page 14: Certifications

    Certifications Thisequipmenthasbeentestedandfoundtocomplywiththe limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable FCC Class A protection against harmful interference when the equipment is operated in a commercial environment. This equipment Digital Device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction...
  • Page 15: Order List

    Order List UA Sensor Type OrderNo. ExternalSensor Temperature, UA10 Humidity PR-K1-3, HighTemperature UA11-K K1-15 PR-T1-3,PR-T1-15 NormalTemperature UA11-T PR-P1-3,PR-P1- CryogenicTemperature UA13 4-20mATransmitter UA20-A 4-20mATransmitter UA20-B 0-1VTransmitter UA20-C tVOC,CO2eq, UA50 AbsoluteHumidity Oxygen, UA52-O2-25 Atmosphericpressure, UA52-O2-25-F Temperature Carbondioxide, UA52-CO2-20 Temperature Carbonmonoxide, UA53-CO-1000 Temperature Sulfurdioxide,Temperature UA53-SO2-50 Nitrogendioxide,...
  • Page 16: Accessories

    Accessories Temperature Type OrderNo. CableLength Sensor PR-K1-3 K Type Thermocouple (TC- K)-50~200°C PR-K1-15 15m TTypeThermocouple(TC-T) PR-T1-3 -200~200°C PR-T1-15 15m PT100 PR-P1-3 -200~200°C PR-P1-15 15m Sensor Data Type OrderNo. Remark Transmitter RN171WC SupportPoE WiFi RN172WC SupportWiFiENT...
  • Page 17 2021 DEKIST Co., Ltd. +82 (0)31-8004-4359 Telephon +82 (0)31-8039-4400 eFax master@dekist.com Email #A1801, 13, Heungdeok 1-ro, Giheung-gu, Yongin-si, Gyeonggi-do, Korea 16954...