Do you have a question about the IGS-5034-00 and is the answer not in the manual?
Questions and answers
Summary of Contents for Tektronix IGS-5034-00
Page 1
Instruction Manual Technician Procedures IGS-5034-00 Fibre Channel Transceiver Test System 070-9968-00 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety...
Page 2
Copyright E Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers and are protected by United States copyright laws and international treaty provisions. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the...
Table of Contents List of Figures Figure 1–1: IGS-5034-00 Fibre Channel Transceiver Test System 1–2 Figure 1–2: Test system shown with the front doors open ..1–3 Figure 1–3: Test system shown with the rear doors open .
Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel. Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 8
CAUTION indicates a hazard to property including the product. Symbols on the Product. The following symbols may appear on the product: WARNING Protective Ground CAUTION Double High Voltage (Earth) Terminal Refer to Manual Insulated Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
To avoid electric shock, do not touch exposed connections. X-Radiation. To avoid x-radiation exposure, do not modify or otherwise alter the high-voltage circuitry or the CRT enclosure. X-ray emissions generated within this product have been sufficiently shielded. Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 10
Service Safety Summary viii Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Product manuals for individual system components are also provided. Terms Used in This Manual This manual uses the following terms: H “Test system,” “system,” or “tester” refers to the IGS-5034-00 Fibre Channel Transceiver Test System H “Device under test,” “DUT,” or device refers to the fiber channel transceiver H “uucp”...
Preface Contacting Tektronix Service Contact your local Tektronix distributor or sales office. Or, visit Support our web site for a listing of worldwide service locations. http://www.tek.com For other In North America: information 1-800-TEK-WIDE (1-800-835-9433) An operator will direct your call.
System software also documents test results for each DUT tested; this test data is accessible by the system administrator and the technician. Figure 1–1 shows the test system as it looks during normal operation. 1–1 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Getting Started Figure 1–1: IGS-5034-00 Fibre Channel Transceiver Test System 1–2 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Getting Started Figure 1–2 shows the test system with the cabinet door open in preparation for maintenance or service. Figure 1–2: Test system shown with the front doors open 1–3 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Getting Started Figure 1–3 shows the test system from the rear with the doors open. Figure 1–3: Test system shown with the rear doors open 1–4 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
H Maintaining ground straps, shoe straps, jackets, and so on H Changing the fiber optic cables H Changing the air filters H Removing instruments from the rack to send for calibration 1–5 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
H Deleting old test results from system H Maintaining cron H Printer tasks H Enabling and disabling print queues H Monitoring print queue for proper operation H Modifying printer configuration files for new printers 1–6 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Functional Check To verify correct test system operation, you should perform the functional check procedure, as described in the Operating Basics chapter of the IGS-5034-00 Fibre Channel Transceiver Test System User Manual. For more information about these tests, refer to the Performance Verification chapter of this manual.
Page 22
Getting Started 1–8 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
System Description Figures 2–1 and 2–2 show the test system instrument locations. Tables 2–1 and 2–2 list the test system instrument descriptions. 2–1 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Reference Figure 2–2: Test system equipment locations, rear view 2–3 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 28
Optical Switch Custom Tektronix, Inc. Optical Switch and housing for P6701A P6701A Optical/Electrical converter, 450 to 1000 nm, DC to inside Option 1 850 MHz, with FC connector option Optical module (19) 2–4 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Test Record File Format. The test record file contains information as follows: H Module bar code identifier H Module test start date and time H Keyword <additional information> H Keyword <additional information> H Module test end date and time 2–7 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
The Standby switch should be in the Remote position for front panel operation or in the Local position to bypass the front panel. As it starts up, the workstation monitor displays status information and other messages. 2–8 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
3. Place the new adapter in the test fixture, carefully align the pairs of interface connectors underneath the adapter, and gently press the adapter into place. 4. Tighten the four screws on the DUT adapter finger-tight. 2–9 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Each instrument on the GPIB bus has a unique address. All instruments connected to the GPIB bus must have different addresses, and the addresses must match what the test system software expects to see. 2–10 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
DUT caused the error message. If the Golden_DUT portion of the test fails, the path loss values may be out of bounds. Check the optical connections. 2–11 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
“Optics did not engage” Message. The test fixture was unable to connect the duplex SC optical cable to the DUT. “Optics did not disengage” Message. The test fixture was unable to disconnect the duplex SC optical cable to the DUT. 2–12 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
20 minutes Ambient Temperature 20_ C to 30_ C Weight 1000 lbs (approximate) Power Consumption < 24 A For specifications pertaining to an individual instrument, refer to the manual(s) for that instrument. 3–1 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 41
WARNING The following servicing instructions are for use only by qualified personnel. To avoid injury, do not perform any servicing other than that stated in the operating instructions unless you are qualified to do so. Refer to all Safety Summaries before performing any service.
Observe laser safety precautions for active laser components and attached optical fibers. Failure to observe these precau- tions can result in permanent eye damage. 4–1 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
For technicians with access to the interior of the system, there are optical ports which carry Class IIIb light levels and can pose laser exposure danger to the human eye if proper precautions are not taken. 4–2 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
When the solenoid is no longer driven, a spring returns the locking pin to its original position such that the lid is no longer locked and the operator may then open the lid. 4–3 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
The buffering includes line drivers, which drop the signal of the original TTL levels down to approximately 0.3 volt peak-peak. Error Detector The BER test of the system relies entirely upon the word comparator located on the main circuit board. 4–4 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
320-1194 Compact keyboard for Voyager and SPARC 530-1442.Mini-DIN to mini-DIN cable Vendor SunExpress (division of Sun Microsystems Inc.) Ordering information SUN-X-SB-400P Quantity: one (1) Ordering information 320-1194 Quantity: one (1) Ordering information 530-1442 Quantity: one (1) 4–5 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Tel: (516) 563-2400 or 1-800-SCAN-234 Fax: (516) 563-2831 Local Rep: Systems Technical Sales 6950 S.W. Hampton St., Suite 308, Tigard, OR 97223 Tel: (503) 624-2347 Fax: (503) 684-8470 Ordering information LS 1220-I200A Quantity: one (1) 4–6 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Each Data Generator card provides 4 output channels. A total of 12 output channels provide parallel 10-bit words, DUT clock, and the test fixture clock. Instrument name HFS9DG2 Vendor Tektronix, Inc. Ordering information HFS9DG2 (modular cards) Quantity: three (3) 4–7 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Bessel-Thompson curve with the 3 dB point at 0.75 the data rate (such as 0.75 x 265.625 MHz). In order to provide such a filter, Tektronix has provided the system with a custom built FFC266. The FFC266 uses a filter component from an outside vendor that is installed in a mechanical package identical to the Tektronix FS Sonet Filters (FS52, FS156, and FS622).
Tektronix, Inc. Ordering information SD22 (Mainframe) Quantity: one (1) Digital Multimeter The Digital Multimeter is a 4.5 digit DMM. Instrument name VX4234 Vendor Tektronix, Inc. Ordering information VX4234 Quantity: one (1) 4–9 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
The Digital I/O instrument sources and receives the low frequency input and output digital signals going to and coming from the test fixture. Instrument name VX4801 Vendor Tektronix, Inc. Ordering information VX4801 Quantity: one (1) 4–10 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Instrument name 400-53R-131 Vendor BCP Inc. 305 East Drive, Suite A Melbourne, FL 32904 Tel: (407) 984-3671 Fax: (407) 728-0487 Contact: Whit Cotten, VP Marketing Ordering information 400-53R-131 Quantity: one (1) 4–11 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
As this cable has a short insertion life, replacements should be kept in stock. Part name C038946, SC Duplex Cable Assembly Vendor Alcoa Fujikura Ltd. Tel: 1-800-395-4388 Rep: Debbie Christopher Tel: 1-800-395-4388 Ordering information C038946 Quantity: one (1) 4–13 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
(such as when current is driving the solenoid as long as lid is locked). Part name Tubular Solenoid Vendor GUARDIAN Electric Manufacturing Co. address: Woodstock, Illinois 60098. Available from Newark. Ordering information T 6x12-CONT-12D Quantity: one (1) 4–14 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
The results of the self test, along with the time it was run, are stored in the system log file. 5–1 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Once the Golden_DUT is installed in the test fixture and the lid is closed, the system performs the functional and performance tests on the Golden_DUT. Any results outside acceptable bounds are noted. This tests the functional aspects of the system. 5–2 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Accessible Class III laser in use! Disable laser source before connecting and disconnecting optical cable to high power BCP laser. Do not look directly into laser light. Permanent eye damage may result. 6–1 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 66
BCP laser and or VXOA41 may need recalibration If the power is less than –10 dBm: *** ERROR Optical Power is too low Check optical cable connections Verify that BCP key switch is in ON position 6–2 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 67
If the power is between -8 dBm and -18 dBm: *** ERROR Optical Power is too low Check optical cable connections Optical cables may need cleaning BCP laser and or VXOA41 may need recalibration 6–3 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 68
3 seconds: Optical Power at OE Convertor = <value> dBm If the measured power is not between 0 dBm and –9 dBm, one of the following messages displays and the procedure terminates. 6–4 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 69
8. Reconnect the VXOA41 Attenuator to the Optical Switch connector labeled 'OPTICAL INPUT from Attenuator and remove PC-to-SC adapter.' 9. Connect an SC-to-SC optical jumper cable at the DUT end. Press <cr> when ready. Type s<cr> to skip. 6–5 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 70
If the power is between –5 dBm and –10 dBm: *** ERROR Optical Power is too low Check optical cable connections Optical cables may need cleaning BCP laser and or VXOA41 may need recalibration 6–6 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 71
Do you want to save these new values? (y=yes n=no) If yes, type the letter y and return. The following message displays as an acknowledgement: Values have been saved. Otherwise the message is: Values not saved. 6–7 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
1. Loosen (1/4 turn) the two adjustment screws shown in Figure 6–1. 2. Position the scanner by sliding he screw heads along the slots. 3. Gently tighten the screws when complete. Adjust Do not adjust Figure 6–1: Bar code scanner adjustment screws 6–8 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Always follow the precautionary measures when handling static-sensitive DUTs. H Minimize handling of static-sensitive DUTs. H Transport and store static-sensitive DUTs in their original containers or on conductive foam. Label any package that contains static-sensitive DUTs. 7–1 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Page 76
Make sure that the ionizer is powered on and that the ionizer air flow toward the test fixture is not obstructed. 7–2 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
It is also important that the DUT is handled properly, so that it does not add any further dust or dirt to the test fixture. Keep the optical connectors on the DUT covered at all times except when testing. 7–3 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
1. Insert the Technician_DUT into the test fixture and close the lid. This exits the automatic test program. 2. When the system returns a prompt, open the test fixture and remove the Technician DUT. 7–4 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
5. From the rear of the system (door opened), carefully pull the cable through so that you can later insert the cable ends into the SC connections on the optical switched module. 7–5 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
5. Reinstall the hose from the front of the system. Figure 7–4 shows how to remove the test fixture. 7–6 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
At a minimum, the filter should be checked at least every three months. The filter is accessed from the front of the system. Figure 7–5 shows the location of the filter. 7–7 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Spring loaded Pogo probes are used to interface electrically to the DUT. Each of Probes these Pogo probes consists of two pieces: a probe tip with integrated spring and a receptacle for the probe tip. (See Figure 7–6.) 7–8 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
(allen) wrench or center punch, gently depress the probe until it is seated. When it is fully seated, the probe should sit at the same height as the others. This completes the Pogo probe replacement procedure. 7–9 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
1. Use the Delrin block as a spacer to set the Pogo probes to the correct height. 2. Solder the receptacle into place. This completes the receptacle replacement procedure. Calibration Individual instruments should be maintained and calibrated at regular intervals of one year. 7–10 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Golden DUT. Any significant variations are noted. If the system passes these tests then there is probably a problem with the DUT(s) in question. If the problem persists please call your Tektronix service representative. NOTE. The modem communication path is not tested by the system. This is the responsibility of the system administrator.
Removing Plug-In Modules. When removing a plug-in module from an instrument, you must first turn off power to the instrument before removing the plug-in module. 7–12 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
6. Verify that the instrument GPIB address is set correctly. (Refer to GPIB Addresses on page 2–10.) Check with the system administrator to make sure that the listed GPIB addresses are current. 7–13 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
If the test fixture needs to be serviced, it can be removed as shown in Figure 7–8. NOTE. The test fixture has the formal part description of IGS-1578-35. Use this part number when contacting Tektronix concerning the test fixture. Loosen two screws to remove conduit clamp.
Page 91
Diagrams This section contains wiring diagrams for the test system, and schematic diagrams for the test fixture. For instrument-level diagrams, refer to the individual instrument manuals. 8–1 Technician Procedures: IGS-5034-00 Fibre Channel Transceiver Test System...
Need help?
Do you have a question about the IGS-5034-00 and is the answer not in the manual?
Questions and answers