Commercial Electric CE610 Use And Care Manual
Commercial Electric CE610 Use And Care Manual

Commercial Electric CE610 Use And Care Manual

Analog multimeter

Advertisement

Available languages

Available languages

Quick Links

USE AND CARE GUIDE
ANALOG MULTIMETER
Questions, problems, missing parts? Before returning to the store,
call Commercial Electric Customer Service
8 a.m. - 6 p.m., EST, Monday - Friday
1-877-527-0313
HOMEDEPOT.COM
THANK YOU
We appreciate the trust and confidence you have placed in Commercial Electric through
the purchase of this analog multimeter. We strive to continually create quality products
designed to enhance your home. Visit us online to see our full line of products available
for your home improvement needs. Thank you for choosing Commercial Electric!
# 749 477
Item
Model # CE610
Table of Contents
Table of Contents
.................................2
Safety Information
...............................2
Warranty
..............................................3
Pre-Operation
......................................4
Package Contents
.....................................4
..............................5
Product Specifications
Range and Accuracy
...................................5
Operating Suggestions
..............................5
..............6
Preparing to Take a Measurement
Reading the Analog Display
........................6
Checking the Internal Battery Condition
Safety Information
SAFETY SYMBOLS
Symbol
Definition
Indicates important safety information.
This marking on the multimeter represents Caution,
risk of electric shock. Consult the manual for the nature of the
potential hazard.
This product is insulated at double insulation (Protection Class II).
CONFORMS TO UL STD. 61010-1,CERTIFIED TO CSA
C
STD.C22.2 NO.61010-1.
Measurement category II, intended for measurements performed on
circuits directly connected to the low voltage installation.
CAT II
Examples are measurements on household appliances,
portable tools, and similar equipment.
This product has been tested to the requirements of
CAN/CSA-C22.2 No. 61010-1, second edition, including Amendment 1,
or a later version of the same standard incorporating the same level
of testing requirements.
This marking on the multimeter represents
a functional earth (ground) terminal.
Operation
...........................................7
Maintenance
....................................15
Care and Cleaning
...........................15
.....7
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CE610 and is the answer not in the manual?

Questions and answers

Summary of Contents for Commercial Electric CE610

  • Page 1 HOMEDEPOT.COM THANK YOU We appreciate the trust and confidence you have placed in Commercial Electric through the purchase of this analog multimeter. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available...
  • Page 2: Safety Information

    Safety Information Pre-Operation PRECAUTIONS PACKAGE CONTENTS WARNING: This manual contains WARNING: Replace worn test leads. information and warnings Do not use test leads with broken necessary for safe operation and or tattered insulation. Only use maintenance of the instrument. test leads meeting ETL, CETL, It is recommended that you read CAT300 IIV 1A specifications.
  • Page 3: Product Specifications

    Pre-Operation (Continued) Pre-Operation (Continued) PRODUCT SPECIFICATIONS PREPARING TO TAKE A MEASUREMENT The following specifications are valid for 23°C (73°F), maximum 60% relative humidity. Fully insert the test leads (A) in the Component Specification correct input jacks (F and G). Measuring ranges 12 measuring ranges The black lead goes into the negative Operating temperature...
  • Page 4 Operation (Continued) Pre-Operation (Continued) CHECKING THE INTERNAL BATTERY CONDITION BEFORE Measuring AC Voltage RESISTANCE AND CONTINUITY TESTS Insert the test leads (A) into the correct Before you make any resistance or continuity tests, check the condition of the internal input jacks by inserting the red test lead battery.
  • Page 5 Operation (Continued) Operation (Continued) Measuring Resistance/Continuity Measuring Resistance/Continuity - Extension Cords CAUTION: For resistance and CAUTION: For resistance and continuity testing, the power to continuity testing, the power to the circuit must be off. the circuit must be off. CAUTION: When switching the unit CAUTION: When switching the unit back and forth from ohms to other back and forth from ohms to other...
  • Page 6 Operation (Continued) Operation (Continued) Measuring Resistance/Continuity - Fuses Measuring Resistance/Continuity - Switches CAUTION: For resistance and CAUTION: For resistance and continuity testing, the power to continuity testing, the power to the circuit must be off. the circuit must be off. CAUTION: When switching the unit CAUTION: When switching the unit back and forth from ohms to other...
  • Page 7: Checking A Battery

    Operation (Continued) Operation (Continued) Measuring DC Milliamp Measuring the Decibel NOTE: For absolute decibel WARNING: Do not apply voltage to measurements, circuit impedance the test leads while the meter is set must be at least 600 ohms in the milliamp range. -0- decibels = 1 milliwat in a 600 Milliamps can also be expressed as thousandths ohm impedance (equivalent to...
  • Page 8: Maintenance

    Questions, problems, missing parts? Before returning to the store, Care and Cleaning call Commercial Electric Customer Service 8 a.m.- 6 p.m., EST, Monday-Friday Avoid placing the meter in areas where vibration, dust, or dirt are present.
  • Page 9: Symboles De Sécurité

    HOMEDEPOT.COM MERCI Nous apprécions la confiance que vous accordez à Commercial Electric en achetant ce détecteur de tension. Nous faisons des efforts continus afin de créer des produits de qualité conçus pour améliorer votre maison. Visitez notre site web pour voir la gamme complète de nos produits disponibles pour vos besoins de bricolage.
  • Page 10: Consignes De Sécurité

    Consignes de Sécurité Pré-Utilisation MISES EN GARDE CONTENU DE L'EMBALLAGE MISE EN GARDE: Ce manuel MISE EN GARDE: Remplacez les contient de l'information et des connexions d'essai endommagées. mises en garde nécessaires à N'utilisez pas les connexions l'utilisation prudente et l'entretient d'essai avec une isolation de cet instrument.
  • Page 11: Informations Sur Le Produit

    Pré-Utilisation (Suite) Pré-Utilisation (Suite) INFORMATIONS SUR LE PRODUIT SE PRÉPARER À MESURER Les informations suivantes sont valides à 23°C (73°F), Insérez les connexions d'essai (A) avec un maximum d'humidité relative de 60%. complètement dans les prises d'entrée (F et G). La connexion noire doit aller dans Composante Spécification la prise négative (F) et la connexion rouge...
  • Page 12 Pré-Utilisation (Suite) Utilisation VÉRIFIER LA CONDITION DE LA PILE INTERNE AVANT D'EFFECTUER DES Mesurer le Voltage AC TEST DE RÉSISTANCE ET CONTINUITÉ Insérez les connexions d'essai (A) dans Avant d'effectuer tout test de résistance ou continuité, vérifiez la condition de la pile interne. les prises d'entrée appropriées en insérant Premièrement, réglez l'interrupteur de plage de mesure (B) à...
  • Page 13 Utilisation (Suite) Utilisation (Suite) Mesurer la Résistance/Continuité Mesurer la Résistance/Continuité - Extensions AVERTISSEMENT: Pour les tests de AVERTISSEMENT: Pour les tests de résistance et continuité, le courant résistance et continuité, le courant du circuit doit être éteint. du circuit doit être éteint. AVERTISSEMENT: Lorsque vous AVERTISSEMENT: Lorsque vous changer le réglage de ohms à...
  • Page 14 Utilisation (Suite) Utilisation (Suite) Measuring Resistance/Continuity - Fuses Mesurer la Résistance/Continuité - Interrupteurs AVERTISSEMENT: Pour les tests de AVERTISSEMENT: Pour les tests de résistance et continuité, le courant résistance et continuité, le courant du circuit doit être éteint. du circuit doit être éteint. AVERTISSEMENT: Lorsque vous AVERTISSEMENT: Lorsque vous changer le réglage de ohms à...
  • Page 15 Utilisation (Suite) Utilisation (Suite) Mesurer les Milliampères DC Mesurer les Décibels IMPORTANT: Pour des mesures de MISE EN GARDE: N'appliquez pas de décibels absolues, l'impédance voltage aux connexions d'essai du circuit doit être d'au moins 600 lorsque le multimètre est réglé à la ohms -0- décibel = 1 milliwatt plage de milliampères.
  • Page 16: Entretien

    Questions, problèmes, pièces manquantes? Avant de retourner en durable des ressources. magasin, appelez le service à la clientèle de Commercial Electric 8 :00 à 16 :00 Heure de l'Est, Lundi-Vendredi Instructions de Nettoyage 1-877-527-0313 Évitez de placer le multimètre dans des endroits où...

This manual is also suitable for:

749 477

Table of Contents