Summary of Contents for Extraflame COMFORT IDRO L80.16

  • Page 1 THERMO PRODUCTS USER MANUAL COMFORT IDRO L80.16 MADE ITALY design & production 004330007 - REV 000...
  • Page 2 APPLY TECHNICAL DATA LABEL...
  • Page 3: Table Of Contents

    FLUE DISCHARGE ............................................8 HYDRAULIC SYSTEM ..................................10 INSTALLATION AND SAFETY DEVICES ..................................10 ANTI-CONDENSATION DEVICE (MANDATORY) .......................... 11 COMFORT IDRO L80.16 DETAILS ..............................12 SAFETY LATCH AND EXTRACTION OF THE INSERT ..............................13 FEATURES ....................................... 14 REARM ..............................................14 FUSE ................................................14 COMFORT INSERT IDRO L80.16 INSTALLATION .........................
  • Page 4: English

    We thank you for having chosen our company; our product is a great heating solution developed from the most advanced technology with top quality machining and modern design, aimed at making you enjoy the fantastic sensation that the heat of a flame gives, in complete safety. WARNINGS This instructions manual is an integral part of the product: make sure that it always accompanies the appliance, even if transferred to another owner...
  • Page 5 RECEIVED INSTRUCTIONS ON SAFE USE OF THE APPLIANCE AND THAT THEY UNDERSTAND THE INHERENT DANGERS. Š THE GENERATOR MUST NOT BE USED BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY AND MENTAL CAPACITIES OR WHO ARE UNSKILLED PERSONS, UNLESS THEY ARE SUPERVISED AND TRAINED REGARDING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
  • Page 6: Routine Maintenance

    THAT SWITCH THE GENERATOR OFF. IF THIS OCCURS, CONTACT THE TECHNICAL AFTER-SALES SERVICE AND ALWAYS DISABLE THE SAFETY SYSTEMS. Š IN THE EVENT THE FLUE CATCHES FIRE, USE SUITABLE SYSTEMS FOR SUFFOCATING THE FLAMES OR REQUEST HELP FROM THE FIRE BRIGADE.
  • Page 7: Installation

    INSTALLATION GENERAL The support surfaces and/or points must have a suitable load-bearing capacity to support the weight of the appliance, of the accessories and coatings. The generator must be on the level for correct operation. The flue extraction and hydraulic connections must be carried out by qualified personnel who must issue documentation of conformity according to the regulations of the country of installation.
  • Page 8: Ventilation And Aeration Of The Installation Premises

    VENTILATION AND AERATION OF THE INSTALLATION PREMISES Ventilation, in the case of a non-watertight generator and/or non-watertight installation, must be carried out respecting the minimum area indicated below (considering the largest of the values suggested: Percentage of the Minimum net opening value of the Appliance categories Reference standard net opening section with respect to the...
  • Page 9 SHARED CHIMNEY FLUE Check on the CE Technical Data Sheet whether the product is suitable for installation in a shared chimney flue (i.e. with multiple connection). Suitable devices can be installed in shared flue systems provided that: Š installation in a shared chimney flue (i.e. with multiple connection) is allowed in the place of installation; Š...
  • Page 10: Hydraulic System

    Standards in force, national, regional and municipal, as well as these instructions. For Italy, installation must be carried out by professionally qualified staff (Ministerial Decree dated 22.01.08 n°37). Extraflame S.p.A. declines all responsibility for damage to objects and/or persons caused by the system. TYPE OF SYSTEM Š...
  • Page 11: Distances Of Safety Devices According To The Standard

    DISTANCES OF SAFETY DEVICES ACCORDING TO THE STANDARD The temperature safety sensors must be in place on the machine at a distance no greater than 30 cm from the flow connection. Whenever the generators lack a device, those missing can be installed on the generator flow pipe, within a distance no greater than 1 m from the machine. COMMISSIONING CHECKS Before connecting the boiler: a) wash all system piping thoroughly in order to remove any residues which might compromise the correct functioning of certain system...
  • Page 12: Comfort Idro L80.16 Details

    COMFORT IDRO L80.16 DETAILS Room air outlet Air vent Room air outlet System draining/filling Door handle Rocker with emergency card Fumes exhaust Pellet hopper Power supply 230V Fumes exhaust Power supply Combustive air 230V input Poker (x2) HYDRAULIC INSTALLATION 3 bar safety drain...
  • Page 13: Safety Latch And Extraction Of The Insert

    SAFETY LATCH AND EXTRACTION OF THE INSERT Use the poker supplied to perform the release/block operation. Holes present on two sides for the extraction of the insert via pokers. Extraction of the insert allows both to load the pellet inside the hopper and to perform routine maintenance (cleaning the ash pipe at year end) or extraordinary (replacement of...
  • Page 14: Features

    FEATURES Water content of the thermo-product heat exchanger (l) 14.6 Volume of expansion vessel integrated into thermo-product (l) 3 bar safety valve integrated into the thermo-product Minimum and maximum pressure switch integrated into the thermo-product Pump integrated into the thermo-product Pump max.
  • Page 15: Comfort Insert Idro L80.16 Installation

    INSERT PREPARATION AND INSTALLATION, SEE ATTACHED FILE "INSERT PREPARATION AND ASSEMBLY" COMFORT INSERT IDRO L80.16 INSTALLATION The insert is supplied with a sliding base in iron that allows it to be installed in a pre-existing chimney. This sliding base allows the insert to be removed easily to load the pellets inside the hopper and for any maintenance or cleaning at the end of the season.
  • Page 16: Fresh Air Ducts

    FRESH AIR DUCTS For correct operation, air must be allowed to recirculate inside the structure that covers the insert in order to prevent the appliance from overheating. To guarantee this, just realise one or more openings in the lower and upper part of the covering. The following measurements must be respected: Lower part (cold air inlet) with total minimum surface 550 cm².
  • Page 17 A hole must be made on the chimney support base (figure 1) for the recirculation of air and to guarantee the combustion air necessary for correct combustion of the insert. See "Air re-circulation pipes" chapter 227.2 Air inlet Base 210.5 (figure 1) If it is not possible to make a hole on the chimney support (figure 1), it is mandatory to realise two lateral holes (figure 2) ion the structure to guarantee the combustion air necessary for correct combustion of the insert.
  • Page 18: Assembly With Pedestal (Optional)

    874.4 (figure 3) To safeguard from any overheating, the Comfort Idro L80.16 is supplied with a probe that analyses the temperature inside the structure and intervenes by reducing the functioning power. THIS VENTILATION SYSTEM IS TOTALLY INDEPENDENT FROM THE AIR INLET FOR COMBUSTION!!
  • Page 19: Front Pellet Loading Kit (Optional)

    FRONT PELLET LOADING KIT (OPTIONAL) The optional pellet loading kit allows to load the pellets into the tank from the front without having to remove the insert (which requires switching off the machine). Further information on accessories is available on the website under the category "accessories".
  • Page 20: Pellets And Loading

    PELLETS AND LOADING Pellets are made by subjecting wood shavings i.e. the rejects of pure unpainted wood from sawmills, carpentry products and products from other activities connected to wood working and transformation, to very high pressures. This type of fuel is fully ecological as no glues are used for its compaction. In fact, pellet compactness is guaranteed over time by a natural substance found in wood: lignin.
  • Page 21: Radio/Emergency Card

    RADIO/EMERGENCY CARD The stove is fitted with an emergency radio card located under the rocker, which allows the basic operation of the stove in the event the LCD handheld remote is damaged or malfunctions. The functions that can be managed from the emergency card are: P1: On/off stove.
  • Page 22: Handheld

    HANDHELD CONFIGURATION RADIO CONTROL DEVICE CODING PROCEDURE: 1. Disconnect the power supply to the stove. 2. Press the keys at the same time until the screen to choose RADIO ID appears. 3. Using the buttons select the new RADIO ID (it is possible to select a RADIO ID between 0 and 63). 4.
  • Page 23: Handheld Features

    HANDHELD FEATURES The handheld is fitted with an LCD backlit display. The display remains lit for 5 seconds. After a certain period of time, in order to minimise battery consumption, the display turns off (sleep mode). It turns on again after pressing the ON/OFF key (6). WARNING! Do not place the handheld in direct or indirect contact with water.
  • Page 24: Display

    DISPLAY SCREEN WITH VENTILATION NOT ENABLED Stby active Chrono active Battery low Power 1-5^ Time Water temperature (H2O) detected in the boiler Set H2O temperature set Text display SCREEN WITH VENTILATION ENABLED Stby active Chrono active Battery low Power 1-5^ Time Water temperature (H2O) Temperature detected in...
  • Page 25: General Menu

    GENERAL MENU FUNCTION FUNCTION Scroll parameters Back - exit key Modify settings On - off key Access menu key POWER AMBIENT TEMP. H2O TEMP. VENTILATION SET CHRONO ENABLE CHRONO EASY SETUP SET PRG 1 SET PRG 2 SET PRG 3 SETTINGS DATE/TIME SET PRG 4...
  • Page 26: Commissioning Settings

    COMMISSIONING SETTINGS Once the supply cable has been connected to the back of the generator, and after the insert has been locked with the latch, proceed with the configuration. DATE AND TIME This menu allows the date and time to be set. To set: OK >...
  • Page 27: Operation And Logic

    OPERATION AND LOGIC Once the previously listed points have been checked, press key for three seconds to ignite the stove. 15 minutes are available for the ignition phase. After ignition and after reaching the control temperature, the stove interrupts the ignition phase and switches to PREPARATION. PREPARATION During the preparation phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to WORK.
  • Page 28: Set

    POWER The menu allows the generator power to be set Minimum power 1, maximum power 5. To set: OK > SET > POWER. ROOM TEMPERATURE The menu allows to set the room temperature to reach. (front ventilation must be active). Range: OFF - 07 - 40°C.
  • Page 29: Set Chrono

    SET CHRONO This function allows the generator's ignition and switch-off to be automatically programmed. By factory default, the SET CHRONO is disabled. The chrono allows the programming of 4 time slots within a day, which can be used every day of the week. Ignition and switch-off times can be set for each time slot, along with the specific days of application for the programmed time slot and the desired temperature.
  • Page 30: Settings

    SETTINGS DATE/TIME Š LANGUAGE SEE CHAPTER: COMMISSIONING SETTINGS. Š SET DEGREES Š DISPLAY The "DISPLAY" menu allows: Š Adjustment of Display contrast. Š Activation/Deactivation of backlight. Š Enabling/disabling of acoustic signal. Š Setting of the timer to turn off the Display backlight. Š...
  • Page 31: Reset

    RESET Allows the user to reset all modifiable values to the default values. To set: OK > SETTINGS > RESET. ADDITIONAL FUNCTIONS If conveyor accessories of the manufacturer are used , the connection must be made by a qualified technician. Contact the dealer for further details LCD HANDHELD REMOTE ROOM PROBE CALIBRATION This mode allows calibration of the room temperature detected by the LCD handheld remote (with ventilation active only).
  • Page 32: Cleaning And Maintenance

    TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM CLEANING AND MAINTENANCE ALWAYS FOLLOW THE INSTRUCTIONS IN COMPLETE SAFETY! Š Make sure that the power cord is unplugged because the generator may have been programmed to switch on.
  • Page 33 EVERY DAY BURN POT AND COMBUSTION CHAMBER: Suck up the residues present in the burn pot Remove the burn pot completely from the relevant compartment; Suck up the ash from the burn pot seat and combustion chamber. Release all holes present in the burn pot using the poker supplied.
  • Page 34: Routine Maintenance Performed By Qualified Technicians

    PERSON, SO AS TO AVOID ALL RISKS. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE: WWW.LANORDICA-EXTRAFLAME.COM ROUTINE MAINTENANCE PERFORMED BY QUALIFIED TECHNICIANS Routine maintenance must be performed at least once a year.
  • Page 35: Routine Maintenance

    ROUTINE MAINTENANCE THE IMAGES ARE ILLUSTRATIONS ONLY. Fumes motor (disassembly and cleaning and fumes pipe and "T"), new silicone in the provided points Gaskets, pellet hopper, inspections, ash drawer and door (replace and apply silicone where indicated) Combustion chamber and heat exchanger (full cleaning) including ignition plug pipe Hopper (complete emptying and cleaning).
  • Page 36: Displays

    Take the stove to OFFconditions using key 1 and repeat the procedure No current during the ignition phase. BLACK OUT described in the "Ignition" chapter. * on models with this function. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM ENGLISH...
  • Page 37 Other restoration operations must be performed by an authorised The flue exhaust pipe is blocked technician. incorrect installation * on models with this function. TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM ENGLISH...
  • Page 38: Disposal

    DISPOSAL INFORMATION FOR MANAGEMENT OF ELECTRIC AND ELECTRONIC APPLIANCE WASTE CONTAINING BATTERIES OR ACCUMULATORS This symbol, which is used on the product, batteries, accumulators or on the packaging or documents, means that at the end of its useful life, this product, the batteries and the accumulators included must not be collected, recycled or disposed of together with domestic waste. Improper management of electric or electronic waste or batteries or accumulators can lead to the leakage of hazardous substances contained in the product.
  • Page 39: Symbol En 16510-1

    Symbol EN 16510-1 EN 16510-1 EXPLANATION Symbol Nominal heat output part Part load heat output CON / INT Appliance operation, Continuos (CON) or Intermittent (INT) / CO Carbon dioxide emission 2 nom 2 part / CO Carbon monoxide emission part Minimum distances to combustible materials - bottom Minimum distances to combustible materials - ceiling Minimum distances to combustible materials - floor in front...
  • Page 40 EXTRAFLAME S.p.A. Via Dell’Artigianato, 12 36030 - MONTECCHIO PRECALCINO (VI) - ITALY   +39.0445.865911 -  +39.0445.865912 -  info@extraflame.it - www.lanordica-extraflame.com MADE ITALY design & production TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW.LANORDICA-EXTRAFLAME.COM...

Table of Contents