  • Page 2: Important Safety Information

    AS/NZS 3000 wiring rules. • Inspect the charging station and connector for any visible damage before each use. • The EVC22KW charger can only be used to charge electric vehicles (EVs) or hybrid vehicles (PHEVs). • Do not install the charging station in an enclosed area to prevent overheating.
  • Page 3: Product List

    RFID Screen Touch button End cap Ethernet wire AC Mains supply To EV Charging lead RS485 PRODUCT LIST EV Wall Charger Wall-mount Bracket Envelope with 3 x bolts and 3 x wall plugs RFID cards Instruction Manual...
  • Page 4: Specifications

    SPECIFICATIONS TYPE 2, 22KW EV WALL CHARGER Product Model No. EVC22KW Power Supply 1 or 3 phase (3P+N+PE) Rated Voltage 230 or 400V AC Input Rated Current Power Frequency 50Hz Output Voltage 230 or 400VAC Output Max Current Rated Power <22kW...
  • Page 5: Pole Mounted Installation

    POLE MOUNTED INSTALLATION 1. Drill holes in the column and insert the screws 2. Position the plate so that the screws align with the holes in the plate and secure it in place 3. Install the EV charger with the plate 4.
  • Page 6: Charging Instructions

    For Single phase connection, refer to wiring in the photo: For Three phase connection, refer to wiring in the photo: CHARGING INSTRUCTIONS CHARGE PREPARATION • After plugging in the charger, follow the on-screen prompts to begin the charging process. START TO CHARGE (RFID) 1.
  • Page 7 Make sure the Charger input voltage is above 180 V. ERROR 8 Over Voltage Fault Make sure the Charger input is below 265 volts. ERROR 9 Relay Breaking Fault Check with PROJECTA ERROR 10 Relay Making Fault Check with PROJECTA ERROR 13 Ground Fault Make sure the Charger ground conductor is not broken and is earthed.
  • Page 8: Warranty Statement

    Check the cable and connector that connects to the car for damage. ERROR 24 Cabinet NTC Fault Check with PROJECTA WARRANTY STATEMENT APPLICABLE ONLY TO PRODUCT SOLD IN AUSTRALIA Brown & Watson International Pty Ltd of 1500 Ferntree Gully Road, Knoxfield, Vic., telephone (03)