Advertisement

Quick Links

英文成册, 材质: 封面光面157g铜版纸, 内页普通80g书写 纸, 尺寸: 98×138mm
User Manual
COMFIER TECHNOLOGY CO.,LTD.
Address:573 BELLEVUE RD
Model: B15S
NEWARK, DE 19713 USA
www.facebook.com/comfiermassager
Fully Automatic Upper Arm
supportus@comfier.com
www.comfier.com
Blood Pressure Monitor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B15S and is the answer not in the manual?

Questions and answers

Summary of Contents for Comfier B15S

  • Page 1 英文成册, 材质: 封面光面157g铜版纸, 内页普通80g书写 纸, 尺寸: 98×138mm User Manual COMFIER TECHNOLOGY CO.,LTD. Address:573 BELLEVUE RD Model: B15S NEWARK, DE 19713 USA www.facebook.com/comfiermassager Fully Automatic Upper Arm supportus@comfier.com www.comfier.com Blood Pressure Monitor...
  • Page 2: Table Of Contents

    CONTENTS 1.Introduction and Intended Use............2.Important Information on Blood Pressure and its Measurement..3.Components of Your Blood Pressure Monitor........4.Using Your Monitor for the First Time..........5.Measurement Procedure..............6.Care and Maintenance..............7.Warranty/Service................8.Certifications..................9.Technical Specifications..............10.EMC Declaration................
  • Page 3: Introduction And Intended Use

    1.Introduction and Intended Use 1.2 Warnings and Precautions Warning: The use of other accessories other than those specified or provided by the equipment manufacturer may cause It enables reliable measurement of systolic and diastolic blood pressure as well as electromagnetic radiation to increase or decrease pulse through the oscillometric method.
  • Page 4: Important Information On Blood Pressure And Its Measurement

    Caution: To avoid damaging the device, keep this unit away from children 2.Important Information on Blood Pressure and pets. and its Measurement Caution: The standard material used for the bladder and tubing is latex-free. Attention: Self-measurement means control, not diagnosis or treatment. 2.1.
  • Page 5: Components Of Your Blood Pressure Monitor

    10.Irregular heartbeat symbol 11.Movement error symbol 12.User B 13.User A 14.Cuff self-checking function 15. Memory symbo 3.3 Features of Model B15S 1.Talking function 2. Double users: 2 x 120 sets memory 3.Cuff self-checking function 4. Irregular heartbeat checking 5. Average value function 6.
  • Page 6: Using Your Monitor For The First Time

    4.2. System Settings 4. Using your Monitor for the First Time After you load the battery or connect power for the monitor,long press the SET button for more than 3s, and then you can start to set. 4.1 Activating the pre-installed batteries Setting the User: Battery Installation Press the MEM button to select User A or User B.
  • Page 7: Measurement Procedure

    5. Measurement Procedure 5.1. Before measurement: • Avoid eating and smoking as well as all forms of exertion directly before measurement. These factors influence the measurement result. Find time to relax by sitting in an armchair in a quiet atmosphere for about ten minutes before taking a measurement.
  • Page 8: Irregular Heartbeat Detector

    5.5. Error Indicates NOTE: Patient Position: The following symbol will appear on the display when measuring abnormal 1) Comfortably seated 2) Legs uncrossed 3) Feet flat on the floor 4) Back and arm supported SYMBOL CAUSE CORRECTION 5) Middle of the CUFF at the level of the right atrium of the heart Replace both batteries with new ones.
  • Page 9: Viewing The Stored Values

    Viewing the stored values The following symbols may appear in this manual, on the Digital Blood Pressure Monitor B15S, or on it's accessories. Some of the symbols With the unit off, press the Memory button. The display first shows "A", then represent standards and compliances associated with the Digital Blood shows an average of all measurements stored in the unit.
  • Page 10: Care And Maintenance

    5.8. Using the AC Adapter 6.Care and Maintenance You may also operate this monitor using the AC adapter (output 5V DC1A Wash hands after each time measurement. with Micro connector). If one device is used by different patients, wash hands before and after Use only the approved AC adapter to avoid damaging the unit.
  • Page 11: Warranty/Service

    Extend Warranty for Free Pressure sensor: Resistive 1) Enter the following URL or scan the QR code below to find COMFIER facebook Measuring range: DIA: 40-130mmHg; SYS: 60-230mmHg page and like it, enter“Warranty” to messenger to extend your warranty from Pulse: 40 to 199 per minute 1 year to 3 years.
  • Page 12 Guidance and manufacture’s declaration – electromagnetic immunity 3) * Caution: This unit has been thoroughly tested and inspected to assure The device is intended for use in the electromagnetic environment specified below. The customer or proper performance and operation! the user of the device should assure that it is used in such an environment. Compliance Immunity test IEC 60601 test level Electromagnetic environment - guidance...
  • Page 13 Guidance and manufacture’s declaration – electromagnetic emission Guidance and manufacturer’s declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer of the The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.

Table of Contents