Please contact the local distributor if you have any questions about differences. The original language of the EIDON UWF Module User Manual is English: in case of conflict of terms, the English version shall prevail.
For detailed and complete information about the EIDON Software, please refer to the EIDON Family User Manual (same user manual for all the models of the EIDON Family devices) Check that EIDON UWF License (Ref. LFLAWFL001) is active before the first use of the EIDON UWFL – Ultra-Widefield Lens. CenterVue...
Page 4
• This User Manual Fig. 1 – Example of main contents of the EIDON UWFL Transport case Available under license only. To request the EIDON UWF License, refer to your CenterVue local distributor. CenterVue EIDON UWF Module User Manual Page 4 of 13...
Please do not use the EIDON UWF Module if your EIDON device is not upgraded with EIDON version ≥ 4.0. software It is not possible to use the same EIDON UWF Module with more than one model of the EIDON Family devices. HOW TO MOUNT AND REMOVE THE EIDON UWFL •...
The following warnings and precautions are to be intended in addition to the ones reported in the EIDON User Manual. Verify the absence of dirt, dust, and scratches. In this condition EIDON UWFL lens can be difficult or impossible to be screwed: please contact to your CenterVue local distributor or CenterVue Authorized Service Center.
The use of the EIDON UWFL does not change the non-mydriatic use of the EIDON Family devices (minimum pupil diameter 2.5 mm). EIDON Family devices used in combination with EIDON UWF Lens compensate for a patient’s spherical refractive error in the range from -8 to +8 Diopters The presence of EIDON UWFL reduces the EIDON Family devices working distance from 28mm to 16 mm.
Fig. 2 – Patient position during exam during exam with EIDON UWF Module Fig. 2 – Position o a patient with deep-set or small orbits during an exam with EIDON UWF Module PERFORMING THE EXAM To perform the exam with EIDON UWF Module as made per standard exam without UWFL, please refer to EIDON Family User Manual for further details and information.
REVIEWING EXAM IMAGES Review of retinal images acquired with EIDON UWF Module is made as per standard images review used on EIDON Family devices without the EIDON UWF Module installed: please, refer to EIDON Family User Manual for further details and information.
EIDON UWFL Transport case (see Fig. 3) Fig. 3 – Position of accessory’s serial number on an EIDON UWFL and labelling position inside the EIDON UWF transport case Labelling might be subject to changes depending on local regulatory requirements.
Page 11
The meaning of the symbols adopted in the EIDON UWF Module labelling is as follows: Symbol Explanation Manufacturer Data Manufacturing Date (yyyymm where mm is 2-digit month and yyyy is 4-digits year) Accessory serial number (where nnnnn is 5-digit serial number)
This section provides details on the optical radiation hazards related to the use of EIDON FA with UWFL. To grant the highest degree of protection to the patient, the values reported here are obtained considering the worst-case scenario of use. CenterVue EIDON UWF Module User Manual Page 12 of 13...
Page 13
• for ANSI Z80.36 (USA), see section 14.4 14.3 ISO 15004-2 Please refer to EIDON Family Devices User Manual 14.4 ANSI Z80.36 Please refer to EIDON Family Devices User Manual CenterVue EIDON UWF Module User Manual Page 13 of 13...
Need help?
Do you have a question about the EIDON UWF and is the answer not in the manual?
Questions and answers