I N S T A L L A T I O N M A N U A L
DUST FREE
UV-C Light/Ionization Total Home Air Purification
General
This device is designed to be installed into an existing HVAC system
for improved indoor air quality.
Before Installation
• Read all instructions carefully. Failure to do so could damage the
equipment or cause harm to yourself or others.
• Acknowledge all warnings.
• Only qualified technicians should perform the installation.
• Electric Shock Hazard. Can cause injury or death. Electrical wiring
of the unit to the HVAC system should be done by a licensed HVAC
technician or electrical installer.
• UV Light Hazard. Can cause serious eye and skin damage.
Do not look at UV-C light. Wear UV-C eye and skin protection.
• Mercury Hazard. Do Not Break. UV-C lamp contains a small amount
of Mercury. May cause redness or irritation. Manage in accordance
with disposal laws - www.lamprecycle.org
WARNING: This product can expose you to chemicals including mercury
and mercury compounds, which is known to the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov
UL Approvals
AIR DUCT MOUNTED ACCESSORY WITH RESPECT TO
ELECTRIC SHOCK, FIRE AND CASUALTY HAZARDS ONLY.
E524994
ZERO OZONE EMISSIONS - Measured ozone emissions
from Dust Free Active Gold during use phase does not
exceed 0.005 PPM as tested by UL 867. UL.com/ECV
EPA Establishment No. 73316-TX-1
Parts Included
• Active Power Supply/Ballast
• Ionizing Cell
• UV-C lamp
• 40VA transformer
• Mounting plate
• Mounting hardware
• Installation instructions
Note: Parts may come pre-assembled.
ACTIVE GOLD
®
Page 1 of 7

Advertisement

loading
Need help?

Need help?

Do you have a question about the DUST FREE ACTIVE GOLD and is the answer not in the manual?

Questions and answers

Summary of Contents for RectorSeal DUST FREE ACTIVE GOLD

  • Page 1 ELECTRIC SHOCK, FIRE AND CASUALTY HAZARDS ONLY. 7" E524994 ZERO OZONE EMISSIONS - Measured ozone emissions from Dust Free Active Gold during use phase does not exceed 0.005 PPM as tested by UL 867. UL.com/ECV EPA Establishment No. 73316-TX-1 Parts Included •...
  • Page 2: Specifications

    DUST FREE ACTIVE GOLD ® Installation Manual Specifications Model Dust Free Active Gold 12" Dust Free Active Gold 6" Product Code DF13071 DF13070 Power Module 8"H X 7"W X 14.5"L 8"H X 7"W X 9.5"L Mounting Plate 8"H x 7"W Electrical 24V 50/60Hz.
  • Page 3 DUST FREE ACTIVE GOLD ® Installation Manual Metal Ductwork Installation • Locate a suitable area of the duct for installation. Minimum 8" area. • If needed, cut away insulation to expose metal duct. • Mark location for 4" opening using the included mounting plate Fig.
  • Page 4 DUST FREE ACTIVE GOLD ® Installation Manual Installation of Dust Free Lightstick Gold IMPORTANT: When installing the Active Gold with remote accessory lamp do not use 40VA transformer provided with the Active Gold unit. You must use the 75VA transformer referenced in Table 2. PERSONAL INJURY OR UNIT DAMAGE HAZARD •...
  • Page 5: Limited Warranty

    3255 Wyandotte St East Windsor, ON N8Y 1E9, Canada  519-966-4901 A CSW Industrials Company. RectorSeal, the logos and other trademarks are property of RectorSeal, LLC, its affiliates or its licensors and are protected by copyright, trademark and other intellectual property laws, and may not be used without permission.
  • Page 6 DUST FREE ACTIVE GOLD ® Installation Manual Page 6 of 7...
  • Page 7 DUST FREE ACTIVE GOLD ® Installation Manual Page 7 of 7...