  • Page 1 IED1516LI / IED1516LI-E Installation Instructions 16 Input Logic Module Document Number: 1217B 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com ©2017 Innovative Electronic Designs, LLC DOC1217B IED005603 RevA 4/17...
  • Page 2: Table Of Contents

    Windows 7, Windows Server, SQL Server, and Internet Explorer are all registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 2 –...
  • Page 3: Important Safety Instructions

    Labeling on products and the Installation Instructions & User Manual may use safety related graphical symbols as shown below to note safety requirements. 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 3 –...
  • Page 4: Safety Considerations

    9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 4 –...
  • Page 5: Preliminary Precautions

    Cela peut créé des courants très élevés où des étincelles pourrait blesser les yeux, fondre les métaux et causer des brûlures. 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 5 –...
  • Page 6: Precautions When Working On Energized Equipment

    The 1516LI-E connects to the 1516LI through the supplied 5-conductor expansion cable. 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 6 –...
  • Page 7: Connections

    The Ethernet PoE connector is used to connect the unit to the network using a standard RJ-45 (Cat 5e or higher, 100BaseTX cable) connector. 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 7 –...
  • Page 8: Wall Mounting

    After unpacking the 1516LI from its shipping carton, install four screws securely in the designated areas. Screw size can be up to a size 6. Figure 2 - Wall Mounting with Screws 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 8 – ©2017 Innovative Electronic Designs, LLC...
  • Page 9: Din Rail Mounting

    Figure 3 - 1516LI Mounting on the DIN Rail Example Figure 4 - 1516LI Rotating and Snapping into Place Example 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 9 – ©2017 Innovative Electronic Designs, LLC...
  • Page 10: Din Rail Mounting (Continued)

    The figure below depicts the completed DIN rail mounted option. Figure 5 - 1516LI - Din Rail Mounted Example 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 10 – ©2017 Innovative Electronic Designs, LLC...
  • Page 11: Removing From Din Rail Mount

    STEP 1: Push the 1516LI in from the right side, and rotate the unit to the right and pull away from the DIN rail. Figure 6 - 1516LI Removing from DIN Rail Example 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 11 –...
  • Page 12: 1516Li Examples

    PoE power that conforms to IEEE 802.3af. Figure 7 - 1516LI Ethernet/PoE Input Connection Example 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 12 – ©2017 Innovative Electronic Designs, LLC...
  • Page 13: 48Vdc Alternate Power Input Connection Example

    Figure 8 - 1516LI Optional 48VDC Alternate Power Input Connection Example 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 13 –...
  • Page 14: Input Connections Example

    The Logic Input Connectors are connected using the supplied 8-pin, 3.81 mm spacing Phoenix plugs. Ensure that the proper polarity is maintained throughout all terminations. Figure 9 - 1516LI Input Connections Example 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 14 – ©2017 Innovative Electronic Designs, LLC...
  • Page 15: Expansion Bus Connection Example

    This will allow the total input capacity up to 32 inputs. Figure 10 - 1516LI TO 1516LI-E Expansion Bus Connection Example 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 15 –...
  • Page 16: 1516Li Initial Configuration

    Once the correct password is entered and the Enter button pressed, one is taken to the Settings page as shown in the example below. 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 16 –...
  • Page 17 When changes are made and saved, the web page will prompt to reset the device via the button and red notification shown in the figure below. 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 17 –...
  • Page 18: Device Recovery

    Note, after the reboot, the device will be at the factory default IP address and so may not be addressable without changing the browser to point to that IP address. 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 18 –...
  • Page 19: Specifications

    Weight ..........................7.3 oz (206.9 g) Environmental Operating Temperature Range ..........–22 ˚F – +149 ˚F (–30 ˚C – +65 ˚C) 9701 Taylorsville Road · Louisville, KY 40299 · Phone (502) 267-7436 · Fax (502) 267-9070 · www.atlasied.com – 19 – ©2017 Innovative Electronic Designs, LLC...
  • Page 20: Fcc Notice