please read and replace the information provided with the respective pages found
in the Model 8800 thermostat and Model 8800 System installation manuals.
The Model 8800 communicating thermostat and Model 8819 distribution panel have been modified to provide enhanced
compatibility with various power supplies and grounding schemes. Please follow the instructions provided in this addendum
to properly install and configure these new products.
these changes effect the 8800 system in three main ways:
1. Power for the thermostat is now derived from the Model 8819 or separate 24VAC transformer (same as the Model
8870/8818 was) instead of the HVAC equipment.
2. The heat pump fault indicator feature has been removed from this product to make room for the new terminal layout.
3. The 8800 can now operate with dry contacts in humidistat mode without the use of a 8024.
If you experience any difficulty with these instructions or the installation of scenarios not discussed in this document, please
contact Aprilaire
Technical Support at (888) 782-8638. Office hours are Monday through Friday, 7:00 a.m. – 5:00 p.m.
®
Central Standard Time.
AdditionAL noteS:
When replacing an 8870 thermostat with the model 8800 thermostat these additional steps are required in
order for proper operation.
1. Replace any 8061 TT Support Modules connected to the thermostat with 8081 TT Support Modules, but in cases where
a single flush mount and/or outdoor sensor is used they can be directly connected to the new 8800 Thermostat and the
Support Module can be eliminated.
2. Replace any 8062 TrH Support Modules connected to the thermostat with 8082 TrH Support Modules.
iMportAnt AddenduM
Model 8800 Addendum
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 8800 Addendum and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aprilaire 8800 Addendum

  • Page 1 Model 8800 Addendum iMportAnt AddenduM please read and replace the information provided with the respective pages found in the Model 8800 thermostat and Model 8800 System installation manuals. The Model 8800 communicating thermostat and Model 8819 distribution panel have been modified to provide enhanced compatibility with various power supplies and grounding schemes.
  • Page 2 (half duplex) installation notes: • Ensure power at the HVAC equipment is off. Refer to Aprilaire HVAC Automation System Installation Manual for communication wiring details. • Loosen screw terminals, insert stripped wire and re-tighten. O and B terminals are both de-energized when system mode is •...
  • Page 3 replaces page 6 of the 8800 thermostat installation manual. replaces page 7 of the 8800 System installation manual. inStALLAtion HeAt puMp SingLe trAnSforMer (uSe JuMper Wire) tWo trAnSforMerS (reMove JuMper Wire) THERMOSTAT IS POWERED FROM 8819 OR 24VAC THERMOSTAT IS POWERED TRANSFORMER FROM 8819 OR 24VAC TRANSFORMER...
  • Page 4 MODEL 8800 THERMOSTAT GRN/WHT 24VAC MODEL 8029 24VAC PLUG-IN TRANSFORMER P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairepartners.com 10009775 12.11 Printed in U.S.A. B2205699A © 2011 Aprilaire – A division of Research Products Corporation...