Hide thumbs Also See for G1RN6AHB012:

Advertisement

Quick Links

Remote Node Installation Guide
Model: G1RN6AHB012
Tarana Wireless, Inc. Proprietary ©2023. All rights reserved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G1RN6AHB012 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tarana G1RN6AHB012

  • Page 1 Remote Node Installation Guide Model: G1RN6AHB012 Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 2: Table Of Contents

    Warranty ................................26 More Information You can download the latest remote node installation guide at the following URL: www.taranawireless.com/rn_manual You can find additional information and videos at the following URL: https://taranawireless.zendesk.com/hc/en- us/sections/1500001232962-FAQ- Troubleshooting-Guides Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 3: Safety And Warnings

    Safety and Warnings Tarana G1 equipment requires adherence to all relevant regulatory, safety, and telecom industry best practice guidelines for outdoor radios. General Warnings Failure to observe these safety precautions may result in personal injury or damage to equipment. • Follow all warnings and instructions marked on this product.
  • Page 4: General Health And Safety Information

    Should local regulations not be mandatory, then safety norms herein will prevail Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 5: Warning Labels

    Llevar a cabo ajustamientos y/o modificaciones a este equipo, sin seguir las instrucciones provistas por este manual u otro documento adicional, podría resultar en lesiones a su persona o daños al equipo, y anular la garantía de este último. 警告 對本设备进行不符合本用户指南,安装手册,或其他补充文件规定的调整和/或 修改可能會导致人身伤害或设备损坏, 并可能导致失 去设备的保修。 Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 6: General Hazards

    Reliable grounding of the RN chassis must be maintained. Connections Power Supply The RN must be powered by a Tarana provided Power over Ethernet (PoE) injector. Maximum Ambient The ambient temperature range for the RN product is -40 degrees C to 55 degrees C. To ensure correct Temperature and to maximize long term component reliability, ambient temperatures must not be exceeded.
  • Page 7: Rn Installation Preparation

    Remote Node Installation Guide RN Installation Preparation Use the following checklists to ensure you have all the required items before beginning a Tarana RN installation. Verify the contents of the Tarana supplied hardware. Tools • #2 Phillips tip screwdriver • 8mm hex socket wrench •...
  • Page 8: Tarana Hardware And Peripherals

    • Ethernet cable cord grip • (8) M5 flanged-head screw with thread lock • RN chassis bracket • RN elevation bracket • Tarana G1 Remote Node (RN) radio unit Figure 3: Tarana Hardware Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 9: Step 1 Of 2: Rn - Physical Installation

    With the RN in place on the elevation bracket, tighten all 4 screws between the chassis bracket and the elevation bracket. Tilt adjustment may be made from 12 degrees up to 5 degrees down. Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 10 With the RN in place on the elevation bracket, tighten both the partially-installed screws and the lower screws connecting the chassis bracket to the elevation bracket. Tilt adjustment may be made from 12 degrees up to 5 degrees down Figure 6: Elevation Bracket Installation (Wall Mount) Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 11: Adjusting Tilt

    Do not measure the tilt angle using the mounting pole or surface as a reference to measure the angle. For example, if you measure relative to the mast, then if the mast is deflected, the remote node tilt angle might move out of compliance. Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 12: Antenna Aiming

    Begin the process by attaching the ground system to the RN chassis. Attach a ground wire with the pre- installed M5 screw that is on the RN as indicated. A ring terminal suitable for the M5 screw should be crimped to the ground wire. Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 13 Insert the cable into the RN Ethernet port and screw the cord grip body into the RN, taking care to not cross thread the plastic threads of the cord grip body with the aluminum threads of the RN enclosure. Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 14 Ethernet cable using a PoE tester. Ensure the PoE injector is protected from the elements in a suitable enclosure or installed indoors. Power Up the RN: Upon receiving power, the RN will undergo the power up process. Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 15 At the end of this period, the LEDs will settle into one of a few common states as described below. For more information about LED behavior, see RN - LED Light Status. Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 16: Logging Into The Rn

    To log into the management interface, connect a laptop with a 1000 Mbps Ethernet port to the Ethernet port of the PoE powering the RN. Assign a static IP address of 192.168.10.10 to the laptop’s Ethernet port. Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 17 IP address for the RN is 192.168.10.2. There is no default VLAN for the RN. NOTE Chrome is the preferred and supported browser. Enter the username “admin’ and password “admin123” when prompted for credentials and click Login. This will bring up the RN’s management interface. Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 18: Step 2 Of 2: Rn - Setup And Connectivity

    Step 2 of 2: RN - Setup and Connectivity Verify Connectivity In the management interface, verify the RN is connected to Tarana Cloud Suite (TCS) by confirming that the hostname of the RN at the top of the screen is in green text.
  • Page 19: Radio State And Alignment Metric

    Once the RN is aimed, the dial responds in real time and may be used as part of antenna aiming during installation. Figure 10: Radio State and Alignment Metric Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 20: Hostname And Data Vlan

    For more information about using VLANs, see VLANs and Quality of Service. NOTE Both hostname and data VLAN parameters can also be set or edited from TCS. Figure 11: Set RN Hostname and Data VLAN Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 21: Geography And Orientation Parameters

    The RN’s web UI should not be used for configuration changes once the initial deployment has been completed. Configuration settings in TCS will overwrite web UI settings. To avoid confusion or incorrect settings being applied, use TCS for configuration once the device is registered and connected to TCS. Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 22: Tcs Confirmation

    Remote Node Installation Guide TCS Confirmation To verify the RN is accessible from the Tarana Cloud Suite (TCS), use an Internet connection external to the RN. Login to Tarana Cloud Suite (TCS) using the URL: https://portal.cloud.taranawireless.com For the username and password, contact the TCS system administrator From the left column, click on “DEVICES”.
  • Page 23: Regulatory And Compliance Information

    FCC 47 CFR FCC Part 15 Subpart B Class B CAN ICES-3(B)/NMB-3(B) RF Exposure FCC 47 CFR FCC Part 2.1091 RSS 102 Responsible party: Tarana Wireless, Inc. 590 Alder Drive, Milpitas, CA 95035 URL: www.taranawireless.com Tarana Wireless, Inc. Proprietary ©2023. All rights reserved...
  • Page 24: Fcc Statement (Us Deployment)

    The operation of this device is prohibited on oil platforms, cars, trains, boats, and aircraft. Operation of transmitters in the 5.925-7.125 GHz band is prohibited for control of or communications with unmanned aircraft systems. Modifications not expressly approved by Tarana Wireless Inc. could void the user's authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 25: Industry Canada Statement (Canada Deployment)

    Cet appareil a été conçu pour garantir que les émissions de radiofréquences sont maintenues dans la bande de fonctionnement dans toutes les conditions de fonctionnement normales répertoriées dans ce manuel. Cet appareil contient une antenne réseau intégrée exclusive à Tarana avec un angle d'inclinaison de 12 degrés dans le pire des cas.
  • Page 26: Warranty

    Warranty Tarana warrants that commencing from the date of shipment to you (and in case of resale to you by a Tarana partner, commencing not more than 90 days after our original shipment), and continuing for a period of twelve (12) months, the hardware will be free from defects in material and workmanship under normal use.